{"title":"附着体类型对下颌种植覆盖义齿基牙负荷分布及残嵴的影响。","authors":"Nobuhiro Yoda, Yoshiki Matsudate, Masaru Abue, Guang Hong, Keiichi Sasaki","doi":"10.1177/1758736015576009","DOIUrl":null,"url":null,"abstract":"<p><p>This study aimed to investigate the effect of attachment type on the load transmitted to implants and the residual ridge in a mandibular two-implant-supported overdenture in a model study. Ball attachments, locator attachments, and round-bar attachments were selected and examined. Static and dynamic vertical loads of 100 N were applied in the right first molar region. The load on the implants was measured by piezoelectric three-dimensional force transducers, and the load on the residual ridge beneath the denture base was measured using a tactile sheet sensor. The load on the implants with ball attachments was significantly higher than that with the other two attachments. The load on the residual ridge with round-bar attachments was significantly higher than that with the other two attachments. Our findings indicate that the three-dimensional load on implants and the residual ridge beneath the denture base is significantly associated with the type of attachment used in implant-supported overdentures. </p>","PeriodicalId":88916,"journal":{"name":"Journal of dental biomechanics","volume":"6 ","pages":"1758736015576009"},"PeriodicalIF":0.0000,"publicationDate":"2015-03-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1177/1758736015576009","citationCount":"16","resultStr":"{\"title\":\"Effect of attachment type on load distribution to implant abutments and the residual ridge in mandibular implant-supported overdentures.\",\"authors\":\"Nobuhiro Yoda, Yoshiki Matsudate, Masaru Abue, Guang Hong, Keiichi Sasaki\",\"doi\":\"10.1177/1758736015576009\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study aimed to investigate the effect of attachment type on the load transmitted to implants and the residual ridge in a mandibular two-implant-supported overdenture in a model study. Ball attachments, locator attachments, and round-bar attachments were selected and examined. Static and dynamic vertical loads of 100 N were applied in the right first molar region. The load on the implants was measured by piezoelectric three-dimensional force transducers, and the load on the residual ridge beneath the denture base was measured using a tactile sheet sensor. The load on the implants with ball attachments was significantly higher than that with the other two attachments. The load on the residual ridge with round-bar attachments was significantly higher than that with the other two attachments. Our findings indicate that the three-dimensional load on implants and the residual ridge beneath the denture base is significantly associated with the type of attachment used in implant-supported overdentures. </p>\",\"PeriodicalId\":88916,\"journal\":{\"name\":\"Journal of dental biomechanics\",\"volume\":\"6 \",\"pages\":\"1758736015576009\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-03-16\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1177/1758736015576009\",\"citationCount\":\"16\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of dental biomechanics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1177/1758736015576009\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2015/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of dental biomechanics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1177/1758736015576009","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2015/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
Effect of attachment type on load distribution to implant abutments and the residual ridge in mandibular implant-supported overdentures.
This study aimed to investigate the effect of attachment type on the load transmitted to implants and the residual ridge in a mandibular two-implant-supported overdenture in a model study. Ball attachments, locator attachments, and round-bar attachments were selected and examined. Static and dynamic vertical loads of 100 N were applied in the right first molar region. The load on the implants was measured by piezoelectric three-dimensional force transducers, and the load on the residual ridge beneath the denture base was measured using a tactile sheet sensor. The load on the implants with ball attachments was significantly higher than that with the other two attachments. The load on the residual ridge with round-bar attachments was significantly higher than that with the other two attachments. Our findings indicate that the three-dimensional load on implants and the residual ridge beneath the denture base is significantly associated with the type of attachment used in implant-supported overdentures.