用光学透射显微镜测量细胞体积

Q1 Health Professions
Michael A. Model
{"title":"用光学透射显微镜测量细胞体积","authors":"Michael A. Model","doi":"10.1002/0471142956.cy1239s72","DOIUrl":null,"url":null,"abstract":"<p>Cell volume is an important parameter in cell adaptation to anisosmotic stress, in the development of apoptosis and necrosis, and in the pathogenesis of several diseases. This unit describes a method for measuring the volume of adherent cells using a standard light microscope. A coverslip with attached cells is placed in a shallow chamber in a medium containing a strongly absorbing and cell-impermeant dye, Acid Blue 9. When such a sample is imaged in transmitted light at a wavelength of maximum dye absorption (630 nm), the resulting contrast quantitatively reflects cell thickness. Once the thickness is known at every point, the volume can be computed as well. Technical details, interpretation of data, and possible artifacts are discussed. Measurements in absolute units require knowledge of the absorption coefficient, and a similar procedure for the measurement of absorption coefficient is described. © 2015 by John Wiley &amp; Sons, Inc.</p>","PeriodicalId":11020,"journal":{"name":"Current Protocols in Cytometry","volume":"72 1","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2015-04-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1002/0471142956.cy1239s72","citationCount":"12","resultStr":"{\"title\":\"Cell Volume Measurements by Optical Transmission Microscopy\",\"authors\":\"Michael A. Model\",\"doi\":\"10.1002/0471142956.cy1239s72\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p>Cell volume is an important parameter in cell adaptation to anisosmotic stress, in the development of apoptosis and necrosis, and in the pathogenesis of several diseases. This unit describes a method for measuring the volume of adherent cells using a standard light microscope. A coverslip with attached cells is placed in a shallow chamber in a medium containing a strongly absorbing and cell-impermeant dye, Acid Blue 9. When such a sample is imaged in transmitted light at a wavelength of maximum dye absorption (630 nm), the resulting contrast quantitatively reflects cell thickness. Once the thickness is known at every point, the volume can be computed as well. Technical details, interpretation of data, and possible artifacts are discussed. Measurements in absolute units require knowledge of the absorption coefficient, and a similar procedure for the measurement of absorption coefficient is described. © 2015 by John Wiley &amp; Sons, Inc.</p>\",\"PeriodicalId\":11020,\"journal\":{\"name\":\"Current Protocols in Cytometry\",\"volume\":\"72 1\",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2015-04-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1002/0471142956.cy1239s72\",\"citationCount\":\"12\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Current Protocols in Cytometry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://onlinelibrary.wiley.com/doi/10.1002/0471142956.cy1239s72\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q1\",\"JCRName\":\"Health Professions\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current Protocols in Cytometry","FirstCategoryId":"1085","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/0471142956.cy1239s72","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"Health Professions","Score":null,"Total":0}
引用次数: 12

摘要

细胞体积是细胞适应异渗胁迫、细胞凋亡和坏死的发展以及多种疾病发病机制的重要参数。本单元描述了一种使用标准光学显微镜测量贴壁细胞体积的方法。将带有附着细胞的盖盖放在一个浅室中,介质中含有一种强吸收且不影响细胞的染料,酸性蓝9。当这样的样品在最大染料吸收波长(630 nm)的透射光下成像时,所得到的对比度定量地反映了细胞厚度。一旦知道了每个点的厚度,就可以计算出体积。讨论了技术细节、数据解释和可能的工件。以绝对单位测量需要了解吸收系数,并描述了测量吸收系数的类似程序。©2015 by John Wiley &儿子,Inc。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Cell Volume Measurements by Optical Transmission Microscopy

Cell volume is an important parameter in cell adaptation to anisosmotic stress, in the development of apoptosis and necrosis, and in the pathogenesis of several diseases. This unit describes a method for measuring the volume of adherent cells using a standard light microscope. A coverslip with attached cells is placed in a shallow chamber in a medium containing a strongly absorbing and cell-impermeant dye, Acid Blue 9. When such a sample is imaged in transmitted light at a wavelength of maximum dye absorption (630 nm), the resulting contrast quantitatively reflects cell thickness. Once the thickness is known at every point, the volume can be computed as well. Technical details, interpretation of data, and possible artifacts are discussed. Measurements in absolute units require knowledge of the absorption coefficient, and a similar procedure for the measurement of absorption coefficient is described. © 2015 by John Wiley & Sons, Inc.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Current Protocols in Cytometry
Current Protocols in Cytometry Health Professions-Medical Laboratory Technology
自引率
0.00%
发文量
0
期刊介绍: Published in affiliation with the International Society for Advancement of Cytometry, Current Protocols in Cytometry is a "best practices" collection that distills and organizes the absolute latest techniques from the top cytometry labs and specialists worldwide. It is the most complete set of peer-reviewed protocols for flow and image cytometry available.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信