使用扩散加权磁共振成像测量限制尺寸:综述。

Magnetic resonance insights Pub Date : 2013-05-19 eCollection Date: 2013-01-01 DOI:10.4137/MRI.S11149
Melanie Martin
{"title":"使用扩散加权磁共振成像测量限制尺寸:综述。","authors":"Melanie Martin","doi":"10.4137/MRI.S11149","DOIUrl":null,"url":null,"abstract":"<p><p>This article reviews a new concept in magnetic resonance as applied to cellular and biological systems. Diffusion weighted magnetic resonance imaging can be used to infer information about restriction sizes of samples being measured. The measurements rely on the apparent diffusion coefficient changing with diffusion times as measurements move from restricted to free diffusion regimes. Pulsed gradient spin echo (PGSE) measurements are limited in the ability to shorten diffusion times and thus are limited in restriction sizes which can be probed. Oscillating gradient spin echo (OGSE) measurements could provide shorter diffusion times so smaller restriction sizes could be probed. </p>","PeriodicalId":74096,"journal":{"name":"Magnetic resonance insights","volume":"6 ","pages":"59-64"},"PeriodicalIF":0.0000,"publicationDate":"2013-05-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.4137/MRI.S11149","citationCount":"18","resultStr":"{\"title\":\"Measuring restriction sizes using diffusion weighted magnetic resonance imaging: a review.\",\"authors\":\"Melanie Martin\",\"doi\":\"10.4137/MRI.S11149\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This article reviews a new concept in magnetic resonance as applied to cellular and biological systems. Diffusion weighted magnetic resonance imaging can be used to infer information about restriction sizes of samples being measured. The measurements rely on the apparent diffusion coefficient changing with diffusion times as measurements move from restricted to free diffusion regimes. Pulsed gradient spin echo (PGSE) measurements are limited in the ability to shorten diffusion times and thus are limited in restriction sizes which can be probed. Oscillating gradient spin echo (OGSE) measurements could provide shorter diffusion times so smaller restriction sizes could be probed. </p>\",\"PeriodicalId\":74096,\"journal\":{\"name\":\"Magnetic resonance insights\",\"volume\":\"6 \",\"pages\":\"59-64\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-05-19\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.4137/MRI.S11149\",\"citationCount\":\"18\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Magnetic resonance insights\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4137/MRI.S11149\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2013/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Magnetic resonance insights","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4137/MRI.S11149","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2013/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 18

摘要

本文综述了磁共振在细胞和生物系统中的应用。扩散加权磁共振成像可以用来推断被测样品的限制尺寸信息。测量依赖于随扩散时间变化的表观扩散系数,当测量从受限扩散状态移动到自由扩散状态时。脉冲梯度自旋回波(PGSE)测量在缩短扩散时间的能力方面受到限制,因此可以探测的约束尺寸有限。振荡梯度自旋回波(OGSE)测量可以提供更短的扩散时间,因此可以探测到更小的限制尺寸。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Measuring restriction sizes using diffusion weighted magnetic resonance imaging: a review.

Measuring restriction sizes using diffusion weighted magnetic resonance imaging: a review.

Measuring restriction sizes using diffusion weighted magnetic resonance imaging: a review.

This article reviews a new concept in magnetic resonance as applied to cellular and biological systems. Diffusion weighted magnetic resonance imaging can be used to infer information about restriction sizes of samples being measured. The measurements rely on the apparent diffusion coefficient changing with diffusion times as measurements move from restricted to free diffusion regimes. Pulsed gradient spin echo (PGSE) measurements are limited in the ability to shorten diffusion times and thus are limited in restriction sizes which can be probed. Oscillating gradient spin echo (OGSE) measurements could provide shorter diffusion times so smaller restriction sizes could be probed.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信