单边剪刀咬伤治疗与一个可移动的板,其中包括一个钛镍线。

Hiroko Ohmori, Takashi Ono
{"title":"单边剪刀咬伤治疗与一个可移动的板,其中包括一个钛镍线。","authors":"Hiroko Ohmori,&nbsp;Takashi Ono","doi":"10.11607/ortho.921","DOIUrl":null,"url":null,"abstract":"<p><p>A plate that incorporates a Ti-Ni alloy wire can rapidly correct scissors bite. This article describes its use in the successful treatment of scissors bite. A female patient aged 7 years, 5 months with mixed dentition presented with a Class I molar relationship, Class I skeletal pattern, and average Frankfort-mandibular plane angle. The maxillary right central incisor was in a crossbite. A unilateral posterior scissors bite was also present on the left side. The plate was fitted and prescribed for nighttime wear. Positive overjet was achieved after 1 month of treatment. The posterior scissors bite was corrected after 3 months of treatment, and the midline shift was ameliorated. Because a Ti-Ni wire maintained a weak continuous force, the treatment period was minimized.</p>","PeriodicalId":89450,"journal":{"name":"Orthodontics : the art and practice of dentofacial enhancement","volume":"14 1","pages":"e222-6"},"PeriodicalIF":0.0000,"publicationDate":"2013-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.11607/ortho.921","citationCount":"6","resultStr":"{\"title\":\"Unilateral scissors bite treated with a removable plate that incorporates a Ti-Ni wire.\",\"authors\":\"Hiroko Ohmori,&nbsp;Takashi Ono\",\"doi\":\"10.11607/ortho.921\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A plate that incorporates a Ti-Ni alloy wire can rapidly correct scissors bite. This article describes its use in the successful treatment of scissors bite. A female patient aged 7 years, 5 months with mixed dentition presented with a Class I molar relationship, Class I skeletal pattern, and average Frankfort-mandibular plane angle. The maxillary right central incisor was in a crossbite. A unilateral posterior scissors bite was also present on the left side. The plate was fitted and prescribed for nighttime wear. Positive overjet was achieved after 1 month of treatment. The posterior scissors bite was corrected after 3 months of treatment, and the midline shift was ameliorated. Because a Ti-Ni wire maintained a weak continuous force, the treatment period was minimized.</p>\",\"PeriodicalId\":89450,\"journal\":{\"name\":\"Orthodontics : the art and practice of dentofacial enhancement\",\"volume\":\"14 1\",\"pages\":\"e222-6\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2013-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.11607/ortho.921\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Orthodontics : the art and practice of dentofacial enhancement\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.11607/ortho.921\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Orthodontics : the art and practice of dentofacial enhancement","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11607/ortho.921","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

一个包含钛镍合金线的板可以快速纠正剪刀咬伤。本文介绍了其在剪刀咬伤成功治疗中的应用。1例女性患者,年龄7岁5个月,混合牙列,磨牙关系为I类,骨型为I类,平均法兰克福-下颌平面角。上颌右中切牙呈交叉咬合。左侧也有单侧后剪咬伤。这个盘子是适合夜间佩戴的。治疗1个月后达到阳性覆盖。治疗3个月后,后剪型咬合得到矫正,中线移位得到改善。由于Ti-Ni线保持弱的连续力,处理时间被最小化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Unilateral scissors bite treated with a removable plate that incorporates a Ti-Ni wire.

A plate that incorporates a Ti-Ni alloy wire can rapidly correct scissors bite. This article describes its use in the successful treatment of scissors bite. A female patient aged 7 years, 5 months with mixed dentition presented with a Class I molar relationship, Class I skeletal pattern, and average Frankfort-mandibular plane angle. The maxillary right central incisor was in a crossbite. A unilateral posterior scissors bite was also present on the left side. The plate was fitted and prescribed for nighttime wear. Positive overjet was achieved after 1 month of treatment. The posterior scissors bite was corrected after 3 months of treatment, and the midline shift was ameliorated. Because a Ti-Ni wire maintained a weak continuous force, the treatment period was minimized.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信