超声内镜增强谐波造影在胰腺疾病中的应用。

Diagnostic and Therapeutic Endoscopy Pub Date : 2012-01-01 Epub Date: 2012-11-01 DOI:10.1155/2012/786239
Can Xu, Zhaoshen Li, Michael Wallace
{"title":"超声内镜增强谐波造影在胰腺疾病中的应用。","authors":"Can Xu,&nbsp;Zhaoshen Li,&nbsp;Michael Wallace","doi":"10.1155/2012/786239","DOIUrl":null,"url":null,"abstract":"<p><p>Endoscopic ultrasonography (EUS) is the most sensitive imaging method for diagnosis of pancreatic tumors. However, it still has limits in the differentiation between pancreatic cancers and inflammatory tumor-like masses. A novel technology, contrast-enhanced harmonic EUS (CH-EUS), has been developed recently. It can visualize both parenchymal perfusion and microvasculature in pancreas without Doppler-related artifacts. Therefore, it is superior to EUS and CT in detecting small pancreatic masses and differential diagnosis of pancreatic masses. CH-EUS could be used for adequate sampling of pancreatic tumors and may predict the pathological features of the pancreatic solid lesions but still cannot replace EUS-FNA now.</p>","PeriodicalId":11288,"journal":{"name":"Diagnostic and Therapeutic Endoscopy","volume":"2012 ","pages":"786239"},"PeriodicalIF":0.0000,"publicationDate":"2012-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/2012/786239","citationCount":"13","resultStr":"{\"title\":\"Contrast-enhanced harmonic endoscopic ultrasonography in pancreatic diseases.\",\"authors\":\"Can Xu,&nbsp;Zhaoshen Li,&nbsp;Michael Wallace\",\"doi\":\"10.1155/2012/786239\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Endoscopic ultrasonography (EUS) is the most sensitive imaging method for diagnosis of pancreatic tumors. However, it still has limits in the differentiation between pancreatic cancers and inflammatory tumor-like masses. A novel technology, contrast-enhanced harmonic EUS (CH-EUS), has been developed recently. It can visualize both parenchymal perfusion and microvasculature in pancreas without Doppler-related artifacts. Therefore, it is superior to EUS and CT in detecting small pancreatic masses and differential diagnosis of pancreatic masses. CH-EUS could be used for adequate sampling of pancreatic tumors and may predict the pathological features of the pancreatic solid lesions but still cannot replace EUS-FNA now.</p>\",\"PeriodicalId\":11288,\"journal\":{\"name\":\"Diagnostic and Therapeutic Endoscopy\",\"volume\":\"2012 \",\"pages\":\"786239\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1155/2012/786239\",\"citationCount\":\"13\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Diagnostic and Therapeutic Endoscopy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1155/2012/786239\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2012/11/1 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Diagnostic and Therapeutic Endoscopy","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/2012/786239","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2012/11/1 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13

摘要

超声内镜(EUS)是诊断胰腺肿瘤最灵敏的影像学方法。然而,在胰腺癌与炎性肿瘤样肿块的鉴别上仍有局限性。对比增强谐波超声(CH-EUS)是近年来发展起来的一种新技术。它可以同时显示胰腺实质灌注和微血管,没有多普勒相关伪影。因此,在发现胰腺小肿块和鉴别诊断胰腺肿块方面优于EUS和CT。CH-EUS可用于胰腺肿瘤的充分采样,并可预测胰腺实性病变的病理特征,但目前尚不能取代EUS-FNA。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Contrast-enhanced harmonic endoscopic ultrasonography in pancreatic diseases.

Endoscopic ultrasonography (EUS) is the most sensitive imaging method for diagnosis of pancreatic tumors. However, it still has limits in the differentiation between pancreatic cancers and inflammatory tumor-like masses. A novel technology, contrast-enhanced harmonic EUS (CH-EUS), has been developed recently. It can visualize both parenchymal perfusion and microvasculature in pancreas without Doppler-related artifacts. Therefore, it is superior to EUS and CT in detecting small pancreatic masses and differential diagnosis of pancreatic masses. CH-EUS could be used for adequate sampling of pancreatic tumors and may predict the pathological features of the pancreatic solid lesions but still cannot replace EUS-FNA now.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信