通过便携式步态节律仪长期监测加速度来确定帕金森步态中步态力和周期的缺陷。

ISRN Neurology Pub Date : 2012-01-01 Epub Date: 2012-10-16 DOI:10.5402/2012/306816
Hiroo Terashi, Hiroya Utsumi, Yohei Ishimura, Tomoko Takazawa, Yasuyuki Okuma, Mitsuru Yoneyama, Hiroshi Mitoma
{"title":"通过便携式步态节律仪长期监测加速度来确定帕金森步态中步态力和周期的缺陷。","authors":"Hiroo Terashi, Hiroya Utsumi, Yohei Ishimura, Tomoko Takazawa, Yasuyuki Okuma, Mitsuru Yoneyama, Hiroshi Mitoma","doi":"10.5402/2012/306816","DOIUrl":null,"url":null,"abstract":"To examine the range of gait acceleration and cycle in daily walking of patients with Parkinson's disease (PD), we compared the gait of 40 patients with PD and 17 normal controls by using a newly developed long-term monitoring device that extracts gait-related accelerations from overall movements-related accelerations. The range of change in gait acceleration, relative to the control, was less than 75% in 12 patients. The range of change in gait cycle was less than 75% in 8 patients. The range of changes in both parameters was less than 75% in 4 patients. The results suggest narrow changes in gait parameters in PD.","PeriodicalId":14626,"journal":{"name":"ISRN Neurology","volume":" ","pages":"306816"},"PeriodicalIF":0.0000,"publicationDate":"2012-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.5402/2012/306816","citationCount":"15","resultStr":"{\"title\":\"Deficits in scaling of gait force and cycle in parkinsonian gait identified by long-term monitoring of acceleration with the portable gait rhythmogram.\",\"authors\":\"Hiroo Terashi, Hiroya Utsumi, Yohei Ishimura, Tomoko Takazawa, Yasuyuki Okuma, Mitsuru Yoneyama, Hiroshi Mitoma\",\"doi\":\"10.5402/2012/306816\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"To examine the range of gait acceleration and cycle in daily walking of patients with Parkinson's disease (PD), we compared the gait of 40 patients with PD and 17 normal controls by using a newly developed long-term monitoring device that extracts gait-related accelerations from overall movements-related accelerations. The range of change in gait acceleration, relative to the control, was less than 75% in 12 patients. The range of change in gait cycle was less than 75% in 8 patients. The range of changes in both parameters was less than 75% in 4 patients. The results suggest narrow changes in gait parameters in PD.\",\"PeriodicalId\":14626,\"journal\":{\"name\":\"ISRN Neurology\",\"volume\":\" \",\"pages\":\"306816\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2012-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.5402/2012/306816\",\"citationCount\":\"15\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ISRN Neurology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.5402/2012/306816\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2012/10/16 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ISRN Neurology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.5402/2012/306816","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2012/10/16 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15

摘要

为了研究帕金森病(PD)患者的步态加速范围和日常行走周期,我们使用一种新开发的长期监测装置,从整体运动相关加速度中提取步态相关加速度,比较了40名PD患者和17名正常对照者的步态。与对照组相比,12例患者的步态加速变化幅度小于75%。8例患者步态周期变化幅度小于75%。在4例患者中,这两个参数的变化范围小于75%。结果表明PD患者的步态参数变化很小。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Deficits in scaling of gait force and cycle in parkinsonian gait identified by long-term monitoring of acceleration with the portable gait rhythmogram.

Deficits in scaling of gait force and cycle in parkinsonian gait identified by long-term monitoring of acceleration with the portable gait rhythmogram.

Deficits in scaling of gait force and cycle in parkinsonian gait identified by long-term monitoring of acceleration with the portable gait rhythmogram.

Deficits in scaling of gait force and cycle in parkinsonian gait identified by long-term monitoring of acceleration with the portable gait rhythmogram.
To examine the range of gait acceleration and cycle in daily walking of patients with Parkinson's disease (PD), we compared the gait of 40 patients with PD and 17 normal controls by using a newly developed long-term monitoring device that extracts gait-related accelerations from overall movements-related accelerations. The range of change in gait acceleration, relative to the control, was less than 75% in 12 patients. The range of change in gait cycle was less than 75% in 8 patients. The range of changes in both parameters was less than 75% in 4 patients. The results suggest narrow changes in gait parameters in PD.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信