基于微呼吸压力传感器系统的高血压治疗系统。

IF 1.3 Q4 ENGINEERING, BIOMEDICAL
Medical Devices-Evidence and Research Pub Date : 2011-01-01 Epub Date: 2011-05-12 DOI:10.2147/MDER.S19971
Ziji Diao, Hongying Liu, Lan Zhu, Xiaoqiang Gao, Suwen Zhao, Xitian Pi, Xiaolin Zheng
{"title":"基于微呼吸压力传感器系统的高血压治疗系统。","authors":"Ziji Diao,&nbsp;Hongying Liu,&nbsp;Lan Zhu,&nbsp;Xiaoqiang Gao,&nbsp;Suwen Zhao,&nbsp;Xitian Pi,&nbsp;Xiaolin Zheng","doi":"10.2147/MDER.S19971","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and methods: </strong>A novel therapeutic system for the treatment of hypertension was developed on the basis of a slow-breath training mechanism, using a microbreathing pressure sensor device for the detection of human respiratory signals attached to the abdomen. The system utilizes a single-chip AT89C51 microcomputer as a core processor, programmed by Microsoft Visual C++6.0 to communicate with a PC via a full-speed PDIUSBD12 interface chip. The programming is based on a slow-breath guided algorithm in which the respiratory signal serves as a physiological feedback parameter. Inhalation and exhalation by the subject is guided by music signals.</p><p><strong>Results and conclusion: </strong>Our study indicates that this microbreathing sensor system may assist in slow-breath training and may help to decrease blood pressure.</p>","PeriodicalId":47140,"journal":{"name":"Medical Devices-Evidence and Research","volume":" ","pages":"51-7"},"PeriodicalIF":1.3000,"publicationDate":"2011-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.2147/MDER.S19971","citationCount":"0","resultStr":"{\"title\":\"Therapeutic hypertension system based on a microbreathing pressure sensor system.\",\"authors\":\"Ziji Diao,&nbsp;Hongying Liu,&nbsp;Lan Zhu,&nbsp;Xiaoqiang Gao,&nbsp;Suwen Zhao,&nbsp;Xitian Pi,&nbsp;Xiaolin Zheng\",\"doi\":\"10.2147/MDER.S19971\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background and methods: </strong>A novel therapeutic system for the treatment of hypertension was developed on the basis of a slow-breath training mechanism, using a microbreathing pressure sensor device for the detection of human respiratory signals attached to the abdomen. The system utilizes a single-chip AT89C51 microcomputer as a core processor, programmed by Microsoft Visual C++6.0 to communicate with a PC via a full-speed PDIUSBD12 interface chip. The programming is based on a slow-breath guided algorithm in which the respiratory signal serves as a physiological feedback parameter. Inhalation and exhalation by the subject is guided by music signals.</p><p><strong>Results and conclusion: </strong>Our study indicates that this microbreathing sensor system may assist in slow-breath training and may help to decrease blood pressure.</p>\",\"PeriodicalId\":47140,\"journal\":{\"name\":\"Medical Devices-Evidence and Research\",\"volume\":\" \",\"pages\":\"51-7\"},\"PeriodicalIF\":1.3000,\"publicationDate\":\"2011-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.2147/MDER.S19971\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Medical Devices-Evidence and Research\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2147/MDER.S19971\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2011/5/12 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"Q4\",\"JCRName\":\"ENGINEERING, BIOMEDICAL\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Medical Devices-Evidence and Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/MDER.S19971","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2011/5/12 0:00:00","PubModel":"Epub","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

摘要

背景与方法:基于慢呼吸训练机制,利用附着在腹部的微呼吸压力传感器装置检测人体呼吸信号,开发了一种治疗高血压的新型治疗系统。该系统以AT89C51单片机为核心处理器,采用Microsoft Visual c++ 6.0编程,通过PDIUSBD12接口芯片与PC机进行高速通信。该程序基于慢呼吸引导算法,其中呼吸信号作为生理反馈参数。受试者的吸气和呼气是由音乐信号引导的。结果和结论:我们的研究表明,这种微呼吸传感器系统可能有助于慢呼吸训练,并可能有助于降低血压。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Therapeutic hypertension system based on a microbreathing pressure sensor system.

Therapeutic hypertension system based on a microbreathing pressure sensor system.

Therapeutic hypertension system based on a microbreathing pressure sensor system.

Therapeutic hypertension system based on a microbreathing pressure sensor system.

Background and methods: A novel therapeutic system for the treatment of hypertension was developed on the basis of a slow-breath training mechanism, using a microbreathing pressure sensor device for the detection of human respiratory signals attached to the abdomen. The system utilizes a single-chip AT89C51 microcomputer as a core processor, programmed by Microsoft Visual C++6.0 to communicate with a PC via a full-speed PDIUSBD12 interface chip. The programming is based on a slow-breath guided algorithm in which the respiratory signal serves as a physiological feedback parameter. Inhalation and exhalation by the subject is guided by music signals.

Results and conclusion: Our study indicates that this microbreathing sensor system may assist in slow-breath training and may help to decrease blood pressure.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
Medical Devices-Evidence and Research
Medical Devices-Evidence and Research ENGINEERING, BIOMEDICAL-
CiteScore
2.80
自引率
0.00%
发文量
41
审稿时长
16 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信