细菌性败血症标志物降钙素原测定方法的评价

Shoko Adachi, Koichi Nakao
{"title":"细菌性败血症标志物降钙素原测定方法的评价","authors":"Shoko Adachi,&nbsp;Koichi Nakao","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Procalcitonin (PCT) is a novel biomarker for diagnosis and severity evaluation of bacterial sepsis. PCT measurement methods provided by Wako Pure Chemical Industries, Ltd. include a fully automated chemiluminescent immunoassay system SphereLight Wako and fully automated immunoanalyzer microTASWako i30 for a quantitative measurement, and immunochromatographic assay method, B R A H M S PCT-Q kit. This time, basic performance of SphereLight Wako and microTASWako i30 was evaluated as quantitative determination methods for PCT. The lower limit of detection for the both methods was 0.02 ng/ml. Correlation coefficients of 0.993 to 0.997 indicated good correlation between the two methods. The both methods allow quick and easy measurement of PCT, therefore they are helpful for diagnosis and severity evaluation of bacterial sepsis.</p>","PeriodicalId":74740,"journal":{"name":"Rinsho Biseibutsu Jinsoku Shindan Kenkyukai shi = JARMAM : Journal of the Association for Rapid Method and Automation in Microbiology","volume":"21 2","pages":"107-9"},"PeriodicalIF":0.0000,"publicationDate":"2010-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Evaluation of measurement method of a bacterial sepsis marker, procalcitonin].\",\"authors\":\"Shoko Adachi,&nbsp;Koichi Nakao\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Procalcitonin (PCT) is a novel biomarker for diagnosis and severity evaluation of bacterial sepsis. PCT measurement methods provided by Wako Pure Chemical Industries, Ltd. include a fully automated chemiluminescent immunoassay system SphereLight Wako and fully automated immunoanalyzer microTASWako i30 for a quantitative measurement, and immunochromatographic assay method, B R A H M S PCT-Q kit. This time, basic performance of SphereLight Wako and microTASWako i30 was evaluated as quantitative determination methods for PCT. The lower limit of detection for the both methods was 0.02 ng/ml. Correlation coefficients of 0.993 to 0.997 indicated good correlation between the two methods. The both methods allow quick and easy measurement of PCT, therefore they are helpful for diagnosis and severity evaluation of bacterial sepsis.</p>\",\"PeriodicalId\":74740,\"journal\":{\"name\":\"Rinsho Biseibutsu Jinsoku Shindan Kenkyukai shi = JARMAM : Journal of the Association for Rapid Method and Automation in Microbiology\",\"volume\":\"21 2\",\"pages\":\"107-9\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Rinsho Biseibutsu Jinsoku Shindan Kenkyukai shi = JARMAM : Journal of the Association for Rapid Method and Automation in Microbiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Rinsho Biseibutsu Jinsoku Shindan Kenkyukai shi = JARMAM : Journal of the Association for Rapid Method and Automation in Microbiology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

降钙素原(PCT)是一种诊断和评估细菌性败血症严重程度的新型生物标志物。Wako Pure Chemical Industries, Ltd.提供的PCT测量方法包括全自动化学发光免疫分析系统SphereLight Wako和用于定量测量的全自动免疫分析仪microTASWako i30,以及免疫层析分析方法,B R a H M S PCT- q试剂盒。本次将SphereLight Wako和microTASWako i30作为PCT的定量检测方法进行基本性能评价,两种方法的检测下限均为0.02 ng/ml。相关系数为0.993 ~ 0.997,表明两种方法相关性较好。两种方法均能快速简便地测定PCT,有助于细菌性脓毒症的诊断和严重程度评价。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[Evaluation of measurement method of a bacterial sepsis marker, procalcitonin].

Procalcitonin (PCT) is a novel biomarker for diagnosis and severity evaluation of bacterial sepsis. PCT measurement methods provided by Wako Pure Chemical Industries, Ltd. include a fully automated chemiluminescent immunoassay system SphereLight Wako and fully automated immunoanalyzer microTASWako i30 for a quantitative measurement, and immunochromatographic assay method, B R A H M S PCT-Q kit. This time, basic performance of SphereLight Wako and microTASWako i30 was evaluated as quantitative determination methods for PCT. The lower limit of detection for the both methods was 0.02 ng/ml. Correlation coefficients of 0.993 to 0.997 indicated good correlation between the two methods. The both methods allow quick and easy measurement of PCT, therefore they are helpful for diagnosis and severity evaluation of bacterial sepsis.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信