{"title":"多酚氧化酶包封法测定苯酚的聚吡咯-聚乙烯磺酸盐复合膜生物传感器的制备。","authors":"Halit Arslan, Fatma Arslan","doi":"10.3109/10731199.2011.585616","DOIUrl":null,"url":null,"abstract":"<p><p>Abstract: In this paper, a novel amperometric phenol biosensor with immobilization of polyphenol oxidase (tyrosinase) on electrochemically polymerized polypyrrole-polyvinylsulphonate (PPy-PVS) film has been accomplished via the entrapment technique on the surface of a platinum electrode. The amperometric determination is based on the electrochemical reduction of quinon generated in the enzymatic reaction of phenol. The effects of pH and temperature were investigated and optimum parameters were found to be 8.0 and 30 °C, respectively. The linear working range of the electrode was 1.0 × 10(-7) - 5.0 × 10(-6) M. The storage stability and operation stability of the enzyme electrode were also studied.</p>","PeriodicalId":8413,"journal":{"name":"Artificial cells, blood substitutes, and immobilization biotechnology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2011-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/10731199.2011.585616","citationCount":"7","resultStr":"{\"title\":\"Preparation of a polypyrrole-polyvinylsulphonate composite film biosensor for determination of phenol based on entrapment of polyphenol oxidase.\",\"authors\":\"Halit Arslan, Fatma Arslan\",\"doi\":\"10.3109/10731199.2011.585616\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Abstract: In this paper, a novel amperometric phenol biosensor with immobilization of polyphenol oxidase (tyrosinase) on electrochemically polymerized polypyrrole-polyvinylsulphonate (PPy-PVS) film has been accomplished via the entrapment technique on the surface of a platinum electrode. The amperometric determination is based on the electrochemical reduction of quinon generated in the enzymatic reaction of phenol. The effects of pH and temperature were investigated and optimum parameters were found to be 8.0 and 30 °C, respectively. The linear working range of the electrode was 1.0 × 10(-7) - 5.0 × 10(-6) M. The storage stability and operation stability of the enzyme electrode were also studied.</p>\",\"PeriodicalId\":8413,\"journal\":{\"name\":\"Artificial cells, blood substitutes, and immobilization biotechnology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2011-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.3109/10731199.2011.585616\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Artificial cells, blood substitutes, and immobilization biotechnology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3109/10731199.2011.585616\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Artificial cells, blood substitutes, and immobilization biotechnology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/10731199.2011.585616","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Preparation of a polypyrrole-polyvinylsulphonate composite film biosensor for determination of phenol based on entrapment of polyphenol oxidase.
Abstract: In this paper, a novel amperometric phenol biosensor with immobilization of polyphenol oxidase (tyrosinase) on electrochemically polymerized polypyrrole-polyvinylsulphonate (PPy-PVS) film has been accomplished via the entrapment technique on the surface of a platinum electrode. The amperometric determination is based on the electrochemical reduction of quinon generated in the enzymatic reaction of phenol. The effects of pH and temperature were investigated and optimum parameters were found to be 8.0 and 30 °C, respectively. The linear working range of the electrode was 1.0 × 10(-7) - 5.0 × 10(-6) M. The storage stability and operation stability of the enzyme electrode were also studied.