用新装置标准化脑干听觉诱发电位。

Ilka do Amaral Soares, Pedro de Lemos Menezes, Aline Tenório Lins Carnaúba, Liliane Desgualdo Pereira
{"title":"用新装置标准化脑干听觉诱发电位。","authors":"Ilka do Amaral Soares,&nbsp;Pedro de Lemos Menezes,&nbsp;Aline Tenório Lins Carnaúba,&nbsp;Liliane Desgualdo Pereira","doi":"10.1590/s0104-56872010000400010","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Standardization of Brainstem Auditory Evoked Potential (BAEP) using a new device.</p><p><strong>Aim: </strong>To standardize BAEP responses using a new device developed (NDD) in Brazil.</p><p><strong>Method: </strong>Analysis of absolute latencies, interpeaks and wave amplitudes of BAEP, using a new device developed to study normal-hearing groups (91 adults) and individuals (15 adults) with bilateral neurosensory hearing loss. Responses obtained in the EP15 hearing device/Interacoustics and the NDD were compared. For this, the following paramenters were used: non-filtered click of 100 microsecond (µs), totaling 2000 stimuli in rarefied polarity, stimulation frequency of 13.1 clicks/s, intensity of 80 decibels normalized hearing level (dB nHL), with a window of 10 milliseconds and bandpass filter between 100 and 3000 Hertz (Hz). Significance level was set at 0.05.</p><p><strong>Results: </strong>Absolute latency and interpeak means for 76 normal-hearing individuals with the NDD were: wave I=1.50, III=3.57, V=5.53, I-III=2.06, III-V=1.96 and I-V=4.02. When analyzing results according to gender, there was a statistically significant difference for the absolute latencies of waves III and V and in interpeaks I-III and I-V. Mean amplitude value of wave I=0.384 microvolt (µV) and of wave V=0.825 µV. There was no statistically significant difference between the absolute latencies and interpeaks of the two devices in the same individual.</p><p><strong>Conclusion: </strong>The components of BAEP with the NDD in normal-hearing subjects were similar regarding the tested ears, with statistically lower latencies in women. The BAEP latencies in the same individual with NDD were similar to those obtained with the EP15 / Interacoustics. Normal values of BAEP were obtained in normal-hearing adults.</p>","PeriodicalId":74581,"journal":{"name":"Pro-fono : revista de atualizacao cientifica","volume":"22 4","pages":"421-6"},"PeriodicalIF":0.0000,"publicationDate":"2010-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1590/s0104-56872010000400010","citationCount":"9","resultStr":"{\"title\":\"Standardization of brainstem auditory evoked potential using a new device.\",\"authors\":\"Ilka do Amaral Soares,&nbsp;Pedro de Lemos Menezes,&nbsp;Aline Tenório Lins Carnaúba,&nbsp;Liliane Desgualdo Pereira\",\"doi\":\"10.1590/s0104-56872010000400010\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background: </strong>Standardization of Brainstem Auditory Evoked Potential (BAEP) using a new device.</p><p><strong>Aim: </strong>To standardize BAEP responses using a new device developed (NDD) in Brazil.</p><p><strong>Method: </strong>Analysis of absolute latencies, interpeaks and wave amplitudes of BAEP, using a new device developed to study normal-hearing groups (91 adults) and individuals (15 adults) with bilateral neurosensory hearing loss. Responses obtained in the EP15 hearing device/Interacoustics and the NDD were compared. For this, the following paramenters were used: non-filtered click of 100 microsecond (µs), totaling 2000 stimuli in rarefied polarity, stimulation frequency of 13.1 clicks/s, intensity of 80 decibels normalized hearing level (dB nHL), with a window of 10 milliseconds and bandpass filter between 100 and 3000 Hertz (Hz). Significance level was set at 0.05.</p><p><strong>Results: </strong>Absolute latency and interpeak means for 76 normal-hearing individuals with the NDD were: wave I=1.50, III=3.57, V=5.53, I-III=2.06, III-V=1.96 and I-V=4.02. When analyzing results according to gender, there was a statistically significant difference for the absolute latencies of waves III and V and in interpeaks I-III and I-V. Mean amplitude value of wave I=0.384 microvolt (µV) and of wave V=0.825 µV. There was no statistically significant difference between the absolute latencies and interpeaks of the two devices in the same individual.</p><p><strong>Conclusion: </strong>The components of BAEP with the NDD in normal-hearing subjects were similar regarding the tested ears, with statistically lower latencies in women. The BAEP latencies in the same individual with NDD were similar to those obtained with the EP15 / Interacoustics. Normal values of BAEP were obtained in normal-hearing adults.</p>\",\"PeriodicalId\":74581,\"journal\":{\"name\":\"Pro-fono : revista de atualizacao cientifica\",\"volume\":\"22 4\",\"pages\":\"421-6\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1590/s0104-56872010000400010\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Pro-fono : revista de atualizacao cientifica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1590/s0104-56872010000400010\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pro-fono : revista de atualizacao cientifica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1590/s0104-56872010000400010","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

背景:利用新装置对脑干听觉诱发电位(BAEP)进行标准化。目的:采用巴西开发的一种新装置(NDD)对BAEP反应进行标准化。方法:采用新研制的BAEP仪对正常听力组(91例)和双侧神经感觉性听力损失组(15例)的BAEP绝对潜伏期、峰间和波幅进行分析。比较了EP15助听器/Interacoustics和NDD中获得的响应。为此,使用了以下参数:100微秒(µs)的非滤波咔哒声,总共2000个稀薄极性的刺激,刺激频率为13.1咔哒声/秒,强度为80分贝标准化听力水平(dB nHL),窗口为10毫秒,带通滤波器在100到3000赫兹(Hz)之间。显著性水平设为0.05。结果:76例听力正常的NDD患者的绝对潜伏期和峰间均值分别为:波I=1.50,波III=3.57,波V=5.53,波I-III=2.06,波III-V=1.96,波I-V=4.02。在按性别分析结果时,III波和V波的绝对潜伏期以及I-III和I-V峰间的绝对潜伏期差异有统计学意义。波I的平均幅值为0.384微伏(µV),波V的平均幅值为0.825µV。在同一个体中,两种装置的绝对潜伏期和峰间期无统计学差异。结论:正常听力受试者的BAEP与NDD的成分在被测耳上相似,女性潜伏期较低。同一NDD患者的BAEP潜伏期与使用EP15 / Interacoustics获得的BAEP潜伏期相似。在听力正常的成人中获得正常的BAEP值。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Standardization of brainstem auditory evoked potential using a new device.

Background: Standardization of Brainstem Auditory Evoked Potential (BAEP) using a new device.

Aim: To standardize BAEP responses using a new device developed (NDD) in Brazil.

Method: Analysis of absolute latencies, interpeaks and wave amplitudes of BAEP, using a new device developed to study normal-hearing groups (91 adults) and individuals (15 adults) with bilateral neurosensory hearing loss. Responses obtained in the EP15 hearing device/Interacoustics and the NDD were compared. For this, the following paramenters were used: non-filtered click of 100 microsecond (µs), totaling 2000 stimuli in rarefied polarity, stimulation frequency of 13.1 clicks/s, intensity of 80 decibels normalized hearing level (dB nHL), with a window of 10 milliseconds and bandpass filter between 100 and 3000 Hertz (Hz). Significance level was set at 0.05.

Results: Absolute latency and interpeak means for 76 normal-hearing individuals with the NDD were: wave I=1.50, III=3.57, V=5.53, I-III=2.06, III-V=1.96 and I-V=4.02. When analyzing results according to gender, there was a statistically significant difference for the absolute latencies of waves III and V and in interpeaks I-III and I-V. Mean amplitude value of wave I=0.384 microvolt (µV) and of wave V=0.825 µV. There was no statistically significant difference between the absolute latencies and interpeaks of the two devices in the same individual.

Conclusion: The components of BAEP with the NDD in normal-hearing subjects were similar regarding the tested ears, with statistically lower latencies in women. The BAEP latencies in the same individual with NDD were similar to those obtained with the EP15 / Interacoustics. Normal values of BAEP were obtained in normal-hearing adults.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信