基于光学图像相关技术的弓丝扭矩表达式测量正畸支架扎翼弹塑性变形。

Journal of dental biomechanics Pub Date : 2010-01-01 Epub Date: 2009-12-13 DOI:10.4061/2010/397037
Ryan A Lacoursiere, David S Nobes, Darren L N Homeniuk, Jason P Carey, Hisham H Badawi, Paul W Major
{"title":"基于光学图像相关技术的弓丝扭矩表达式测量正畸支架扎翼弹塑性变形。","authors":"Ryan A Lacoursiere,&nbsp;David S Nobes,&nbsp;Darren L N Homeniuk,&nbsp;Jason P Carey,&nbsp;Hisham H Badawi,&nbsp;Paul W Major","doi":"10.4061/2010/397037","DOIUrl":null,"url":null,"abstract":"<p><p>Orthodontic lingual root movement (torque) is an important aspect of treatment biomechanics and is typically achieved by torsion of a rectangular wire within the orthodontic bracket slot which introduces a force couple. The magnitude of the force moment achieved by wire torsion may be influenced by deformation of the orthodontic bracket. A device utilizing an optical image correlation technique has been developed to accurately quantify bracket slot dimensional changes during application of wire torsion. Simultaneous torque moment magnitude, degrees of wire twist, and bracket slot dimension data can be gathered. Bracket tie wing elastic deformation when loaded was demonstrated and plastic deformation was also observed with a single rotation of the wire.</p>","PeriodicalId":88916,"journal":{"name":"Journal of dental biomechanics","volume":"2010 ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2010-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.4061/2010/397037","citationCount":"25","resultStr":"{\"title\":\"Measurement of orthodontic bracket tie wing elastic and plastic deformation by arch wire torque expression utilizing an optical image correlation technique.\",\"authors\":\"Ryan A Lacoursiere,&nbsp;David S Nobes,&nbsp;Darren L N Homeniuk,&nbsp;Jason P Carey,&nbsp;Hisham H Badawi,&nbsp;Paul W Major\",\"doi\":\"10.4061/2010/397037\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Orthodontic lingual root movement (torque) is an important aspect of treatment biomechanics and is typically achieved by torsion of a rectangular wire within the orthodontic bracket slot which introduces a force couple. The magnitude of the force moment achieved by wire torsion may be influenced by deformation of the orthodontic bracket. A device utilizing an optical image correlation technique has been developed to accurately quantify bracket slot dimensional changes during application of wire torsion. Simultaneous torque moment magnitude, degrees of wire twist, and bracket slot dimension data can be gathered. Bracket tie wing elastic deformation when loaded was demonstrated and plastic deformation was also observed with a single rotation of the wire.</p>\",\"PeriodicalId\":88916,\"journal\":{\"name\":\"Journal of dental biomechanics\",\"volume\":\"2010 \",\"pages\":\"\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2010-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.4061/2010/397037\",\"citationCount\":\"25\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of dental biomechanics\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.4061/2010/397037\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2009/12/13 0:00:00\",\"PubModel\":\"Epub\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of dental biomechanics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.4061/2010/397037","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2009/12/13 0:00:00","PubModel":"Epub","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 25

摘要

正畸舌根运动(扭矩)是治疗生物力学的一个重要方面,通常通过扭转正畸支架槽内的矩形金属丝来实现,从而引入力偶。正畸托架的变形会影响金属丝扭转所获得的力矩的大小。研制了一种利用光学图像相关技术精确量化金属丝扭转作用下支架缝隙尺寸变化的装置。同时可采集力矩大小、线扭度、支架槽尺寸等数据。支架系带翼在加载时发生弹性变形,钢丝单次旋转时也会发生塑性变形。
本文章由计算机程序翻译,如有差异,请以英文原文为准。

Measurement of orthodontic bracket tie wing elastic and plastic deformation by arch wire torque expression utilizing an optical image correlation technique.

Measurement of orthodontic bracket tie wing elastic and plastic deformation by arch wire torque expression utilizing an optical image correlation technique.

Measurement of orthodontic bracket tie wing elastic and plastic deformation by arch wire torque expression utilizing an optical image correlation technique.

Measurement of orthodontic bracket tie wing elastic and plastic deformation by arch wire torque expression utilizing an optical image correlation technique.

Orthodontic lingual root movement (torque) is an important aspect of treatment biomechanics and is typically achieved by torsion of a rectangular wire within the orthodontic bracket slot which introduces a force couple. The magnitude of the force moment achieved by wire torsion may be influenced by deformation of the orthodontic bracket. A device utilizing an optical image correlation technique has been developed to accurately quantify bracket slot dimensional changes during application of wire torsion. Simultaneous torque moment magnitude, degrees of wire twist, and bracket slot dimension data can be gathered. Bracket tie wing elastic deformation when loaded was demonstrated and plastic deformation was also observed with a single rotation of the wire.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信