D M Obzansky, E G Gorman, S P Kramer, I S Masulli, E A Nuzzaci, W F Skogen
{"title":"维格临床化学系统大麻素自动筛选方法的建立及分析性能。","authors":"D M Obzansky, E G Gorman, S P Kramer, I S Masulli, E A Nuzzaci, W F Skogen","doi":"10.1155/S1463924697000187","DOIUrl":null,"url":null,"abstract":"<p><p>A fully automated, random access method for the determination of cannabinoids (UTHC) was developed for the Dimension AR and XL clinical chemistry systems. The method utilizes Abuscreen ONLINE reagents and a multianalyte liquid calibrator containing 11-nor-Delta(9)-THC-9-carboxylic acid. Within-run and total reproducibility, determined using NCCLS protocol EP5- T2, was less than 0.6% and 1.6% CV, respectively, at all concentrations. Calibration stability was retained for at least 30 days. An extensive evaluation of non-structurally related drugs and various physiological substances indicated lack of interference in the method. No sample carry-over was observed following a specimen containing 1886 ng/ml 11-nor-Delta(9)-THC-9-carboxylic acid. A 99.1% agreement (N = 445 samples) was found between an EMIT based method on the aca discrete clinical analyser and the Dimension UTHC method.Dimension clinical chemistry system and aca discrete clinical analyser are registered trademarks of Dade International.</p>","PeriodicalId":22600,"journal":{"name":"The Journal of Automatic Chemistry","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1997-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1155/S1463924697000187","citationCount":"1","resultStr":"{\"title\":\"Development and analytical performance of an automated screening method for cannabinoids on the Dimension clinical chemistry system.\",\"authors\":\"D M Obzansky, E G Gorman, S P Kramer, I S Masulli, E A Nuzzaci, W F Skogen\",\"doi\":\"10.1155/S1463924697000187\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A fully automated, random access method for the determination of cannabinoids (UTHC) was developed for the Dimension AR and XL clinical chemistry systems. The method utilizes Abuscreen ONLINE reagents and a multianalyte liquid calibrator containing 11-nor-Delta(9)-THC-9-carboxylic acid. Within-run and total reproducibility, determined using NCCLS protocol EP5- T2, was less than 0.6% and 1.6% CV, respectively, at all concentrations. Calibration stability was retained for at least 30 days. An extensive evaluation of non-structurally related drugs and various physiological substances indicated lack of interference in the method. No sample carry-over was observed following a specimen containing 1886 ng/ml 11-nor-Delta(9)-THC-9-carboxylic acid. A 99.1% agreement (N = 445 samples) was found between an EMIT based method on the aca discrete clinical analyser and the Dimension UTHC method.Dimension clinical chemistry system and aca discrete clinical analyser are registered trademarks of Dade International.</p>\",\"PeriodicalId\":22600,\"journal\":{\"name\":\"The Journal of Automatic Chemistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1997-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1155/S1463924697000187\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Journal of Automatic Chemistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1155/S1463924697000187\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of Automatic Chemistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1155/S1463924697000187","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Development and analytical performance of an automated screening method for cannabinoids on the Dimension clinical chemistry system.
A fully automated, random access method for the determination of cannabinoids (UTHC) was developed for the Dimension AR and XL clinical chemistry systems. The method utilizes Abuscreen ONLINE reagents and a multianalyte liquid calibrator containing 11-nor-Delta(9)-THC-9-carboxylic acid. Within-run and total reproducibility, determined using NCCLS protocol EP5- T2, was less than 0.6% and 1.6% CV, respectively, at all concentrations. Calibration stability was retained for at least 30 days. An extensive evaluation of non-structurally related drugs and various physiological substances indicated lack of interference in the method. No sample carry-over was observed following a specimen containing 1886 ng/ml 11-nor-Delta(9)-THC-9-carboxylic acid. A 99.1% agreement (N = 445 samples) was found between an EMIT based method on the aca discrete clinical analyser and the Dimension UTHC method.Dimension clinical chemistry system and aca discrete clinical analyser are registered trademarks of Dade International.