改良微量测定法测定血清总胆红素和直接胆红素。

The Italian journal of biochemistry Pub Date : 2007-06-01
Afsheen Aman, Shah Ali Ul Qader, Saeeda Bano
{"title":"改良微量测定法测定血清总胆红素和直接胆红素。","authors":"Afsheen Aman,&nbsp;Shah Ali Ul Qader,&nbsp;Saeeda Bano","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Estimation of total and direct bilirubin in serum plays an important role in differential diagnosis of hyperbilirubinemia. Several direct spectrophotometric methods are commercially available for total and direct bilirubin estimation in which the amount of the sample (serum) varies from 200 ml to 800 ml. It is difficult to collect such amount of serum from infants, as neonatal jaundice is the most common problem in this age group. To overcome this problem modified micro assay method was developed using dimethylsulfoxide (DMSO). The amount of the serum sample is reduced from 100 ml to 20 ml per test for both total and direct bilirubin. A method comparison study was performed using 100 consecutive serum samples, by modified micro assay method and a reference Jendrassik-Grof method. Total bilirubin in these human serum samples ranged from 0.4-15.0 mg/dl and direct bilirubin ranged from 0.05-12.0 mg/dl. The results conclude that modified micro assay method had significant correlation with r-value of 0.99989 for total serum bilirubin and with r-value of 0.99971 for direct serum bilirubin. Linearity of the method is 20 mg/dl and 15 mg/dl for total and direct bilirubin, respectively. Monoreagent used during the assay is stable for 24 hours at 2-8 degrees C while the kit is stable for one year at 2-8 degrees C. In conclusion this micro assay method is rapid, reliable, simple and accurate for the estimation of total and direct bilirubin with small serum quantities. It is equally reliable for manual; semi automated and automated chemistry analyzers.</p>","PeriodicalId":22527,"journal":{"name":"The Italian journal of biochemistry","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2007-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Estimation of total and direct serum bilirubin using modified micro assay method.\",\"authors\":\"Afsheen Aman,&nbsp;Shah Ali Ul Qader,&nbsp;Saeeda Bano\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Estimation of total and direct bilirubin in serum plays an important role in differential diagnosis of hyperbilirubinemia. Several direct spectrophotometric methods are commercially available for total and direct bilirubin estimation in which the amount of the sample (serum) varies from 200 ml to 800 ml. It is difficult to collect such amount of serum from infants, as neonatal jaundice is the most common problem in this age group. To overcome this problem modified micro assay method was developed using dimethylsulfoxide (DMSO). The amount of the serum sample is reduced from 100 ml to 20 ml per test for both total and direct bilirubin. A method comparison study was performed using 100 consecutive serum samples, by modified micro assay method and a reference Jendrassik-Grof method. Total bilirubin in these human serum samples ranged from 0.4-15.0 mg/dl and direct bilirubin ranged from 0.05-12.0 mg/dl. The results conclude that modified micro assay method had significant correlation with r-value of 0.99989 for total serum bilirubin and with r-value of 0.99971 for direct serum bilirubin. Linearity of the method is 20 mg/dl and 15 mg/dl for total and direct bilirubin, respectively. Monoreagent used during the assay is stable for 24 hours at 2-8 degrees C while the kit is stable for one year at 2-8 degrees C. In conclusion this micro assay method is rapid, reliable, simple and accurate for the estimation of total and direct bilirubin with small serum quantities. It is equally reliable for manual; semi automated and automated chemistry analyzers.</p>\",\"PeriodicalId\":22527,\"journal\":{\"name\":\"The Italian journal of biochemistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2007-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Italian journal of biochemistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Italian journal of biochemistry","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

血清总胆红素和直接胆红素的测定对高胆红素血症的鉴别诊断具有重要意义。市面上有几种直接分光光度法可用于总胆红素和直接胆红素的估计,其中样品(血清)的量从200毫升到800毫升不等。很难从婴儿身上收集到这种量的血清,因为新生儿黄疸是这个年龄组最常见的问题。为了克服这一问题,采用二甲基亚砜(DMSO)建立了改进的微量测定方法。对于总胆红素和直接胆红素,每次测试血清样品的量从100毫升减少到20毫升。采用改良微量法和参比Jendrassik-Grof法对100份连续血清样本进行方法比较研究。这些人血清样本中的总胆红素范围为0.4-15.0 mg/dl,直接胆红素范围为0.05-12.0 mg/dl。结果表明,改进的微量法与血清总胆红素的r值为0.99989,与直接血清胆红素的r值为0.99971具有显著的相关性。总胆红素和直接胆红素的线性关系分别为20 mg/dl和15 mg/dl。测定过程中使用的单试剂在2-8℃条件下稳定24小时,试剂盒在2-8℃条件下稳定1年。总之,该微量测定方法快速、可靠、简便、准确,适用于少量血清中总胆红素和直接胆红素的测定。手动时同样可靠;半自动和自动化化学分析仪。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Estimation of total and direct serum bilirubin using modified micro assay method.

Estimation of total and direct bilirubin in serum plays an important role in differential diagnosis of hyperbilirubinemia. Several direct spectrophotometric methods are commercially available for total and direct bilirubin estimation in which the amount of the sample (serum) varies from 200 ml to 800 ml. It is difficult to collect such amount of serum from infants, as neonatal jaundice is the most common problem in this age group. To overcome this problem modified micro assay method was developed using dimethylsulfoxide (DMSO). The amount of the serum sample is reduced from 100 ml to 20 ml per test for both total and direct bilirubin. A method comparison study was performed using 100 consecutive serum samples, by modified micro assay method and a reference Jendrassik-Grof method. Total bilirubin in these human serum samples ranged from 0.4-15.0 mg/dl and direct bilirubin ranged from 0.05-12.0 mg/dl. The results conclude that modified micro assay method had significant correlation with r-value of 0.99989 for total serum bilirubin and with r-value of 0.99971 for direct serum bilirubin. Linearity of the method is 20 mg/dl and 15 mg/dl for total and direct bilirubin, respectively. Monoreagent used during the assay is stable for 24 hours at 2-8 degrees C while the kit is stable for one year at 2-8 degrees C. In conclusion this micro assay method is rapid, reliable, simple and accurate for the estimation of total and direct bilirubin with small serum quantities. It is equally reliable for manual; semi automated and automated chemistry analyzers.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信