使用双环触控散光眼内透镜进行白内障手术后的散光矫正效率和旋转稳定性评估:一年随访。

Biomedicine Hub Pub Date : 2021-02-17 eCollection Date: 2021-01-01 DOI:10.1159/000513894
Ladislav Viktor Nováček, Marie Němcová, Kateřina Tyx, Kristýna Lahodová, Leoš Rejmont, Pavel Rozsíval, Pavel Studený
{"title":"使用双环触控散光眼内透镜进行白内障手术后的散光矫正效率和旋转稳定性评估:一年随访。","authors":"Ladislav Viktor Nováček, Marie Němcová, Kateřina Tyx, Kristýna Lahodová, Leoš Rejmont, Pavel Rozsíval, Pavel Studený","doi":"10.1159/000513894","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>The aim of this study was to assess the clinical outcomes, predictability of results, efficiency of astigmatism correction, and rotational stability of the Bi-Flex 677TAY (Medicontur Medical Engineering Ltd., Zsámbék, Hungary) monofocal toric intraocular lens (IOL) designed for cataract patients with astigmatism.</p><p><strong>Methods: </strong>The IOLs were implanted either mono- or binocularly, following routine cataract surgery. Visual and refractive outcomes, as well as off-axis rotation were assessed throughout a 1-year follow-up period. All clinical data for this work were collected retrospectively. Vector analysis based on the Alpins method was performed to assess the efficiency of astigmatism correction.</p><p><strong>Results: </strong>No complications or adverse events occurred during surgery or the follow-up period. IOL implantation brought 88% of eyes into the ±0.50 D, and 100% into the ± 1.00 D range compared to the target spherical equivalent refraction, emmetropia. Astigmatism correction brought similar results: 94% of eyes had a residual cylindrical error of not higher than ±0.50 D, and 97% were within ±1.00 D. Vector analysis resulted in a correction index of 0.96 and a difference vector of 0.17. Both refractive and visual outcomes showed long-term stability. During the 12-month follow-up period, no eyes had a rotation of >5°. Absolute rotation after 1 year was 1.42 ± 1.89° (median = 0°), while signed rotation was 1.06 ± 2.12° (median = 0°).</p><p><strong>Conclusion: </strong>The Bi-Flex 677TAY monofocal toric IOL, designed by Medicontur Medical Engineering Ltd., represents an efficient and safe solution for cataract patients with astigmatism. Clinical and refractive outcomes are predictable, and rotational stability ensures long-term visual comfort.</p>","PeriodicalId":9075,"journal":{"name":"Biomedicine Hub","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"2021-02-17","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7991491/pdf/bmh-0006-0030.pdf","citationCount":"0","resultStr":"{\"title\":\"Evaluation of Astigmatism-Correcting Efficiency and Rotational Stability after Cataract Surgery with a Double-Loop Haptic Toric Intraocular Lens: A 1-Year Follow-Up.\",\"authors\":\"Ladislav Viktor Nováček, Marie Němcová, Kateřina Tyx, Kristýna Lahodová, Leoš Rejmont, Pavel Rozsíval, Pavel Studený\",\"doi\":\"10.1159/000513894\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objectives: </strong>The aim of this study was to assess the clinical outcomes, predictability of results, efficiency of astigmatism correction, and rotational stability of the Bi-Flex 677TAY (Medicontur Medical Engineering Ltd., Zsámbék, Hungary) monofocal toric intraocular lens (IOL) designed for cataract patients with astigmatism.</p><p><strong>Methods: </strong>The IOLs were implanted either mono- or binocularly, following routine cataract surgery. Visual and refractive outcomes, as well as off-axis rotation were assessed throughout a 1-year follow-up period. All clinical data for this work were collected retrospectively. Vector analysis based on the Alpins method was performed to assess the efficiency of astigmatism correction.</p><p><strong>Results: </strong>No complications or adverse events occurred during surgery or the follow-up period. IOL implantation brought 88% of eyes into the ±0.50 D, and 100% into the ± 1.00 D range compared to the target spherical equivalent refraction, emmetropia. Astigmatism correction brought similar results: 94% of eyes had a residual cylindrical error of not higher than ±0.50 D, and 97% were within ±1.00 D. Vector analysis resulted in a correction index of 0.96 and a difference vector of 0.17. Both refractive and visual outcomes showed long-term stability. During the 12-month follow-up period, no eyes had a rotation of >5°. Absolute rotation after 1 year was 1.42 ± 1.89° (median = 0°), while signed rotation was 1.06 ± 2.12° (median = 0°).</p><p><strong>Conclusion: </strong>The Bi-Flex 677TAY monofocal toric IOL, designed by Medicontur Medical Engineering Ltd., represents an efficient and safe solution for cataract patients with astigmatism. Clinical and refractive outcomes are predictable, and rotational stability ensures long-term visual comfort.</p>\",\"PeriodicalId\":9075,\"journal\":{\"name\":\"Biomedicine Hub\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2021-02-17\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC7991491/pdf/bmh-0006-0030.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Biomedicine Hub\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1159/000513894\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"2021/1/1 0:00:00\",\"PubModel\":\"eCollection\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedicine Hub","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1159/000513894","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2021/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

研究目的本研究的目的是评估专为散光白内障患者设计的 Bi-Flex 677TAY(匈牙利zsámbék,Medicontur Medical Engineering Ltd.)单焦散光眼内人工晶体(IOL)的临床疗效、结果可预测性、散光矫正效率和旋转稳定性:方法:在常规白内障手术后,单眼或双眼植入人工晶体。在为期一年的随访期间,对视觉和屈光效果以及离轴旋转进行了评估。这项工作的所有临床数据均为回顾性收集。根据阿尔宾斯方法进行了矢量分析,以评估散光矫正的效率:结果:手术和随访期间均未出现并发症或不良反应。与目标球面等效屈光度(散光)相比,人工晶体植入术使88%的眼睛达到±0.50 D,100%的眼睛达到±1.00 D。散光矫正也取得了类似的效果:矢量分析得出的矫正指数为 0.96,差异矢量为 0.17。屈光和视力结果均显示出长期稳定性。在 12 个月的随访期间,没有一只眼睛的旋转度大于 5°。1 年后的绝对旋转度为 1.42 ± 1.89°(中位数 = 0°),而符号旋转度为 1.06 ± 2.12°(中位数 = 0°):由Medicontur Medical Engineering Ltd.设计的Bi-Flex 677TAY单焦点散光人工晶体是散光白内障患者的一种高效、安全的解决方案。临床和屈光效果是可预测的,旋转稳定性确保了长期的视觉舒适度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Evaluation of Astigmatism-Correcting Efficiency and Rotational Stability after Cataract Surgery with a Double-Loop Haptic Toric Intraocular Lens: A 1-Year Follow-Up.

Objectives: The aim of this study was to assess the clinical outcomes, predictability of results, efficiency of astigmatism correction, and rotational stability of the Bi-Flex 677TAY (Medicontur Medical Engineering Ltd., Zsámbék, Hungary) monofocal toric intraocular lens (IOL) designed for cataract patients with astigmatism.

Methods: The IOLs were implanted either mono- or binocularly, following routine cataract surgery. Visual and refractive outcomes, as well as off-axis rotation were assessed throughout a 1-year follow-up period. All clinical data for this work were collected retrospectively. Vector analysis based on the Alpins method was performed to assess the efficiency of astigmatism correction.

Results: No complications or adverse events occurred during surgery or the follow-up period. IOL implantation brought 88% of eyes into the ±0.50 D, and 100% into the ± 1.00 D range compared to the target spherical equivalent refraction, emmetropia. Astigmatism correction brought similar results: 94% of eyes had a residual cylindrical error of not higher than ±0.50 D, and 97% were within ±1.00 D. Vector analysis resulted in a correction index of 0.96 and a difference vector of 0.17. Both refractive and visual outcomes showed long-term stability. During the 12-month follow-up period, no eyes had a rotation of >5°. Absolute rotation after 1 year was 1.42 ± 1.89° (median = 0°), while signed rotation was 1.06 ± 2.12° (median = 0°).

Conclusion: The Bi-Flex 677TAY monofocal toric IOL, designed by Medicontur Medical Engineering Ltd., represents an efficient and safe solution for cataract patients with astigmatism. Clinical and refractive outcomes are predictable, and rotational stability ensures long-term visual comfort.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信