全髋关节置换术中全羟基磷灰石包覆钛股骨干骨折3例报告。

Dinesh K Sharma, Stuart Brooks, Stuart Creasey, Brian Lewis
{"title":"全髋关节置换术中全羟基磷灰石包覆钛股骨干骨折3例报告。","authors":"Dinesh K Sharma, Stuart Brooks, Stuart Creasey, Brian Lewis","doi":"10.1080/00016470410004175","DOIUrl":null,"url":null,"abstract":"Copyright © Taylor & Francis 2004. ISSN 0001–6470. Printed in Sweden – all rights reserved. DOI 10.1080/00016470410004175 Fracture of the femoral stem of a total hip replacement has become an unusual but well recognised complication when using cement. Fracture of the femoral stem in an uncemented total hip replacement is rare, however. We report 3 cases of fracture of the femoral stem (2 of which were done in our hospital and 1 that was referred from outside) with a hydroxyapatite-coated prosthesis where the metal was fully covered by the hydroxyapatite coating. The femoral prosthesis used was the JRI (Joint Replacement Instrumentation Ltd. or Furlong THR, London, UK), made of wrought titanium alloy with the surface completely covered with vacuum plasma sprayed hydroxyapatite coating. This coating is of 96% purity, has a thickness of 150 microns and a bond strength of 60 Mpa. It is attached to a 50-micron thick porous titanium undercoating. The stem has 3 parts. The rectangular proximal third with a small fin to counteract rotation is placed in the trochanter area. Further distally, there is a cone section to create mechanical stability. The distal portion is cylindrical. The design allows the distal femur to be over-reamed by 2 mm.","PeriodicalId":75403,"journal":{"name":"Acta orthopaedica Scandinavica","volume":"75 6","pages":"768-71"},"PeriodicalIF":0.0000,"publicationDate":"2004-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/00016470410004175","citationCount":"10","resultStr":"{\"title\":\"Fracture of fully hydroxyapatite-coated titanium femoral stem of a total hip replacement--a report of 3 cases.\",\"authors\":\"Dinesh K Sharma, Stuart Brooks, Stuart Creasey, Brian Lewis\",\"doi\":\"10.1080/00016470410004175\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Copyright © Taylor & Francis 2004. ISSN 0001–6470. Printed in Sweden – all rights reserved. DOI 10.1080/00016470410004175 Fracture of the femoral stem of a total hip replacement has become an unusual but well recognised complication when using cement. Fracture of the femoral stem in an uncemented total hip replacement is rare, however. We report 3 cases of fracture of the femoral stem (2 of which were done in our hospital and 1 that was referred from outside) with a hydroxyapatite-coated prosthesis where the metal was fully covered by the hydroxyapatite coating. The femoral prosthesis used was the JRI (Joint Replacement Instrumentation Ltd. or Furlong THR, London, UK), made of wrought titanium alloy with the surface completely covered with vacuum plasma sprayed hydroxyapatite coating. This coating is of 96% purity, has a thickness of 150 microns and a bond strength of 60 Mpa. It is attached to a 50-micron thick porous titanium undercoating. The stem has 3 parts. The rectangular proximal third with a small fin to counteract rotation is placed in the trochanter area. Further distally, there is a cone section to create mechanical stability. The distal portion is cylindrical. The design allows the distal femur to be over-reamed by 2 mm.\",\"PeriodicalId\":75403,\"journal\":{\"name\":\"Acta orthopaedica Scandinavica\",\"volume\":\"75 6\",\"pages\":\"768-71\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1080/00016470410004175\",\"citationCount\":\"10\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Acta orthopaedica Scandinavica\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/00016470410004175\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta orthopaedica Scandinavica","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/00016470410004175","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 10

摘要

本文章由计算机程序翻译,如有差异,请以英文原文为准。
Fracture of fully hydroxyapatite-coated titanium femoral stem of a total hip replacement--a report of 3 cases.
Copyright © Taylor & Francis 2004. ISSN 0001–6470. Printed in Sweden – all rights reserved. DOI 10.1080/00016470410004175 Fracture of the femoral stem of a total hip replacement has become an unusual but well recognised complication when using cement. Fracture of the femoral stem in an uncemented total hip replacement is rare, however. We report 3 cases of fracture of the femoral stem (2 of which were done in our hospital and 1 that was referred from outside) with a hydroxyapatite-coated prosthesis where the metal was fully covered by the hydroxyapatite coating. The femoral prosthesis used was the JRI (Joint Replacement Instrumentation Ltd. or Furlong THR, London, UK), made of wrought titanium alloy with the surface completely covered with vacuum plasma sprayed hydroxyapatite coating. This coating is of 96% purity, has a thickness of 150 microns and a bond strength of 60 Mpa. It is attached to a 50-micron thick porous titanium undercoating. The stem has 3 parts. The rectangular proximal third with a small fin to counteract rotation is placed in the trochanter area. Further distally, there is a cone section to create mechanical stability. The distal portion is cylindrical. The design allows the distal femur to be over-reamed by 2 mm.
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信