暴露于面部或腿部局部气流时的热感觉和舒适。

Kazuaki Yamashita, Juntaro Matsuo, Yutaka Tochihara, Youichiro Kondo, Shizuka Takayama, Hiroki Nagayama
{"title":"暴露于面部或腿部局部气流时的热感觉和舒适。","authors":"Kazuaki Yamashita,&nbsp;Juntaro Matsuo,&nbsp;Yutaka Tochihara,&nbsp;Youichiro Kondo,&nbsp;Shizuka Takayama,&nbsp;Hiroki Nagayama","doi":"10.2114/jpa.24.61","DOIUrl":null,"url":null,"abstract":"<p><p>The present study examined the contribution of local airflow temperature to thermal sensation and comfort in humans. Eight healthy male students were exposed to local airflow to their faces (summer condition) or legs (winter condition) for 30 minutes. Local airflow temperature (Tf) was maintained at 18 degrees C to 36 degrees C, and ambient temperature (Ta) was maintained at 17.4 degrees C to 31.4 degrees C. Each subject was exposed to 16 conditions chosen from the combination of Tf and Ta. Based on the results of multiple regression analysis, the standardized partial regression coefficient of Tf and Ta were determined to be 0.93 and 0.13 in the summer condition, and 0.71 and 0.36 in the winter condition at the end of the exposure. Also, thermal comfort was observed to depend closely on the interrelation between Tf and Ta. The present data suggested that local airflow temperature is an important thermal factor regarding thermal sensation and comfort.</p>","PeriodicalId":80293,"journal":{"name":"Journal of physiological anthropology and applied human science","volume":"24 1","pages":"61-6"},"PeriodicalIF":0.0000,"publicationDate":"2005-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.2114/jpa.24.61","citationCount":"15","resultStr":"{\"title\":\"Thermal sensation and comfort during exposure to local airflow to face or legs.\",\"authors\":\"Kazuaki Yamashita,&nbsp;Juntaro Matsuo,&nbsp;Yutaka Tochihara,&nbsp;Youichiro Kondo,&nbsp;Shizuka Takayama,&nbsp;Hiroki Nagayama\",\"doi\":\"10.2114/jpa.24.61\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The present study examined the contribution of local airflow temperature to thermal sensation and comfort in humans. Eight healthy male students were exposed to local airflow to their faces (summer condition) or legs (winter condition) for 30 minutes. Local airflow temperature (Tf) was maintained at 18 degrees C to 36 degrees C, and ambient temperature (Ta) was maintained at 17.4 degrees C to 31.4 degrees C. Each subject was exposed to 16 conditions chosen from the combination of Tf and Ta. Based on the results of multiple regression analysis, the standardized partial regression coefficient of Tf and Ta were determined to be 0.93 and 0.13 in the summer condition, and 0.71 and 0.36 in the winter condition at the end of the exposure. Also, thermal comfort was observed to depend closely on the interrelation between Tf and Ta. The present data suggested that local airflow temperature is an important thermal factor regarding thermal sensation and comfort.</p>\",\"PeriodicalId\":80293,\"journal\":{\"name\":\"Journal of physiological anthropology and applied human science\",\"volume\":\"24 1\",\"pages\":\"61-6\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2005-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.2114/jpa.24.61\",\"citationCount\":\"15\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of physiological anthropology and applied human science\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2114/jpa.24.61\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of physiological anthropology and applied human science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2114/jpa.24.61","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 15

摘要

本研究考察了局部气流温度对人体热感觉和舒适的贡献。8名健康的男学生被暴露在局部气流中30分钟(夏季条件下)或腿部(冬季条件下)。局部气流温度(Tf)维持在18℃~ 36℃,环境温度(Ta)维持在17.4℃~ 31.4℃,每名受试者暴露在从Tf和Ta组合中选择的16种条件下。根据多元回归分析结果,夏季暴露结束时Tf和Ta的标准化偏回归系数分别为0.93和0.13,冬季暴露结束时Tf和Ta的标准化偏回归系数分别为0.71和0.36。此外,热舒适密切依赖于Tf和Ta之间的相互关系。目前的数据表明,局部气流温度是影响热感觉和舒适的重要热因素。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Thermal sensation and comfort during exposure to local airflow to face or legs.

The present study examined the contribution of local airflow temperature to thermal sensation and comfort in humans. Eight healthy male students were exposed to local airflow to their faces (summer condition) or legs (winter condition) for 30 minutes. Local airflow temperature (Tf) was maintained at 18 degrees C to 36 degrees C, and ambient temperature (Ta) was maintained at 17.4 degrees C to 31.4 degrees C. Each subject was exposed to 16 conditions chosen from the combination of Tf and Ta. Based on the results of multiple regression analysis, the standardized partial regression coefficient of Tf and Ta were determined to be 0.93 and 0.13 in the summer condition, and 0.71 and 0.36 in the winter condition at the end of the exposure. Also, thermal comfort was observed to depend closely on the interrelation between Tf and Ta. The present data suggested that local airflow temperature is an important thermal factor regarding thermal sensation and comfort.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信