受核影响的传统和特殊类型住宅的损坏。

P A RANDALL
{"title":"受核影响的传统和特殊类型住宅的损坏。","authors":"P A RANDALL","doi":"10.2172/4029823","DOIUrl":null,"url":null,"abstract":"Ten residential structures of wood, brick, lightweight reinforced concrete block, and lightweight precast concrete slabs were exposed in pairs to the effects of a nuclear device of approximately 30 kt yield, detonated atop a 500-ft tower. The houses represented various structural types, and two houses of each type were tested. One house was located at an anticipated overpressure at which collapse or major damage might be expected and the other was located at an anticipated overpressure at which damage without collapse might be expected. The one-story reinforced lightweight concrete block house and the one-story precast lightweight concrete house suffered only minor structural damage. Photographs are included of the houses both before and after damage. Motion pictures were made during the event and were analyzed for information on thermal and blast effects. Recommendations are included for strengthening the structures within the limits of practical economy and so providing increased protection to dwelling structures. (C.H.)","PeriodicalId":86826,"journal":{"name":"ORINS [reports]. U.S. Atomic Energy Commission","volume":"WT-1194 ","pages":"1-83"},"PeriodicalIF":0.0000,"publicationDate":"1961-04-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"9","resultStr":"{\"title\":\"Damage to conventional and special types of residences exposed to nuclear effects.\",\"authors\":\"P A RANDALL\",\"doi\":\"10.2172/4029823\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"Ten residential structures of wood, brick, lightweight reinforced concrete block, and lightweight precast concrete slabs were exposed in pairs to the effects of a nuclear device of approximately 30 kt yield, detonated atop a 500-ft tower. The houses represented various structural types, and two houses of each type were tested. One house was located at an anticipated overpressure at which collapse or major damage might be expected and the other was located at an anticipated overpressure at which damage without collapse might be expected. The one-story reinforced lightweight concrete block house and the one-story precast lightweight concrete house suffered only minor structural damage. Photographs are included of the houses both before and after damage. Motion pictures were made during the event and were analyzed for information on thermal and blast effects. Recommendations are included for strengthening the structures within the limits of practical economy and so providing increased protection to dwelling structures. (C.H.)\",\"PeriodicalId\":86826,\"journal\":{\"name\":\"ORINS [reports]. U.S. Atomic Energy Commission\",\"volume\":\"WT-1194 \",\"pages\":\"1-83\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1961-04-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"9\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"ORINS [reports]. U.S. Atomic Energy Commission\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.2172/4029823\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"ORINS [reports]. U.S. Atomic Energy Commission","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2172/4029823","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 9

摘要

本文章由计算机程序翻译,如有差异,请以英文原文为准。
Damage to conventional and special types of residences exposed to nuclear effects.
Ten residential structures of wood, brick, lightweight reinforced concrete block, and lightweight precast concrete slabs were exposed in pairs to the effects of a nuclear device of approximately 30 kt yield, detonated atop a 500-ft tower. The houses represented various structural types, and two houses of each type were tested. One house was located at an anticipated overpressure at which collapse or major damage might be expected and the other was located at an anticipated overpressure at which damage without collapse might be expected. The one-story reinforced lightweight concrete block house and the one-story precast lightweight concrete house suffered only minor structural damage. Photographs are included of the houses both before and after damage. Motion pictures were made during the event and were analyzed for information on thermal and blast effects. Recommendations are included for strengthening the structures within the limits of practical economy and so providing increased protection to dwelling structures. (C.H.)
求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信