汽车事故中严重眼损伤的预测:眼的静态和动态破裂压力。

Eric A Kennedy, Katherine D Voorhies, Ian P Herring, Amber L Rath, Stefan M Duma
{"title":"汽车事故中严重眼损伤的预测:眼的静态和动态破裂压力。","authors":"Eric A Kennedy,&nbsp;Katherine D Voorhies,&nbsp;Ian P Herring,&nbsp;Amber L Rath,&nbsp;Stefan M Duma","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The purpose of this paper is to determine the static and dynamic rupture pressures of 20 human and 20 porcine eyes. This study found the static test results show an average rupture pressure for porcine eyes of 1.00 +/- 0.18 MPa while the average rupture pressure for human eyes was 0.36 +/- 0.20 MPa. For dynamic loading, the average porcine rupture pressure was 1.64 +/- 0.32 MPa, and the average rupture pressure for human eyes was 0.91 +/- 0.29 MPa. Significant differences are found between average rupture pressures from all four groups of tests (p = 0.01). A risk function has been developed and predicts a 50% risk of globe rupture at 1.02 MPa, 1.66 MPa, 0.35 MPa, and 0.90 MPa internal pressure for porcine static, porcine dynamic, human static, and human dynamic loading conditions, respectively.</p>","PeriodicalId":80490,"journal":{"name":"Annual proceedings. Association for the Advancement of Automotive Medicine","volume":"48 ","pages":"165-79"},"PeriodicalIF":0.0000,"publicationDate":"2004-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3217427/pdf/aam48_165.pdf","citationCount":"0","resultStr":"{\"title\":\"Prediction of severe eye injuries in automobile accidents: static and dynamic rupture pressure of the eye.\",\"authors\":\"Eric A Kennedy,&nbsp;Katherine D Voorhies,&nbsp;Ian P Herring,&nbsp;Amber L Rath,&nbsp;Stefan M Duma\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The purpose of this paper is to determine the static and dynamic rupture pressures of 20 human and 20 porcine eyes. This study found the static test results show an average rupture pressure for porcine eyes of 1.00 +/- 0.18 MPa while the average rupture pressure for human eyes was 0.36 +/- 0.20 MPa. For dynamic loading, the average porcine rupture pressure was 1.64 +/- 0.32 MPa, and the average rupture pressure for human eyes was 0.91 +/- 0.29 MPa. Significant differences are found between average rupture pressures from all four groups of tests (p = 0.01). A risk function has been developed and predicts a 50% risk of globe rupture at 1.02 MPa, 1.66 MPa, 0.35 MPa, and 0.90 MPa internal pressure for porcine static, porcine dynamic, human static, and human dynamic loading conditions, respectively.</p>\",\"PeriodicalId\":80490,\"journal\":{\"name\":\"Annual proceedings. Association for the Advancement of Automotive Medicine\",\"volume\":\"48 \",\"pages\":\"165-79\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2004-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC3217427/pdf/aam48_165.pdf\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annual proceedings. Association for the Advancement of Automotive Medicine\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annual proceedings. Association for the Advancement of Automotive Medicine","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

本文的目的是测定20只人和20只猪眼睛的静态和动态破裂压力。本研究发现,静态试验结果表明,猪眼睛的平均破裂压力为1.00 +/- 0.18 MPa,而人眼的平均破裂压力为0.36 +/- 0.20 MPa。动态加载时,猪的平均破裂压力为1.64±0.32 MPa,人眼的平均破裂压力为0.91±0.29 MPa。四组试验的平均破裂压力之间存在显著差异(p = 0.01)。建立了一个风险函数,预测在猪静态、猪动态、人静态和人动态加载条件下,在1.02 MPa、1.66 MPa、0.35 MPa和0.90 MPa内压下,球体破裂的风险分别为50%。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Prediction of severe eye injuries in automobile accidents: static and dynamic rupture pressure of the eye.

The purpose of this paper is to determine the static and dynamic rupture pressures of 20 human and 20 porcine eyes. This study found the static test results show an average rupture pressure for porcine eyes of 1.00 +/- 0.18 MPa while the average rupture pressure for human eyes was 0.36 +/- 0.20 MPa. For dynamic loading, the average porcine rupture pressure was 1.64 +/- 0.32 MPa, and the average rupture pressure for human eyes was 0.91 +/- 0.29 MPa. Significant differences are found between average rupture pressures from all four groups of tests (p = 0.01). A risk function has been developed and predicts a 50% risk of globe rupture at 1.02 MPa, 1.66 MPa, 0.35 MPa, and 0.90 MPa internal pressure for porcine static, porcine dynamic, human static, and human dynamic loading conditions, respectively.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信