肩胛上缺口分型的观察者间可靠性和观察者内可重复性。

Martin Dunkelgrun, Kazuho Iesaka, Samuel S Park, Frederick J Kummer, Joseph D Zuckerman
{"title":"肩胛上缺口分型的观察者间可靠性和观察者内可重复性。","authors":"Martin Dunkelgrun,&nbsp;Kazuho Iesaka,&nbsp;Samuel S Park,&nbsp;Frederick J Kummer,&nbsp;Joseph D Zuckerman","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The size and shape of the suprascapular notch may be a factor in suprascapular nerve entrapment. The suprascapular notches of 623 scapulae were digitally photographed and used to determine notch type and area. Three researchers used to different classification systems for suprascapular notch typing. These systems were compared for interobserver reliability and intraobserver reproducibility using the kappa test. The mean kappa value for the classification used by Rengachary and colleagues was 0.468 and for the classification used by Ticker and associates was 0.531 for the inferior border of the notch and 0.736 for the superior border of the notch. The classification system used by Ticker and associates was more reliable and reproducible and produced both a superior and an inferior classification, making it possibly more clinically relevant than the classification system used by Rengachary and colleagues.</p>","PeriodicalId":77050,"journal":{"name":"Bulletin (Hospital for Joint Diseases (New York, N.Y.))","volume":"61 3-4","pages":"118-22"},"PeriodicalIF":0.0000,"publicationDate":"2003-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Interobserver reliability and intraobserver reproducibility in suprascapular notch typing.\",\"authors\":\"Martin Dunkelgrun,&nbsp;Kazuho Iesaka,&nbsp;Samuel S Park,&nbsp;Frederick J Kummer,&nbsp;Joseph D Zuckerman\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The size and shape of the suprascapular notch may be a factor in suprascapular nerve entrapment. The suprascapular notches of 623 scapulae were digitally photographed and used to determine notch type and area. Three researchers used to different classification systems for suprascapular notch typing. These systems were compared for interobserver reliability and intraobserver reproducibility using the kappa test. The mean kappa value for the classification used by Rengachary and colleagues was 0.468 and for the classification used by Ticker and associates was 0.531 for the inferior border of the notch and 0.736 for the superior border of the notch. The classification system used by Ticker and associates was more reliable and reproducible and produced both a superior and an inferior classification, making it possibly more clinically relevant than the classification system used by Rengachary and colleagues.</p>\",\"PeriodicalId\":77050,\"journal\":{\"name\":\"Bulletin (Hospital for Joint Diseases (New York, N.Y.))\",\"volume\":\"61 3-4\",\"pages\":\"118-22\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Bulletin (Hospital for Joint Diseases (New York, N.Y.))\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Bulletin (Hospital for Joint Diseases (New York, N.Y.))","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

肩胛上切迹的大小和形状可能是肩胛上神经夹持的一个因素。对623条肩胛骨的肩胛上切迹进行了数码摄影,并确定了切迹的类型和面积。三位研究者对肩胛上切迹分型采用了不同的分类系统。使用kappa测试比较这些系统的观察者之间的可靠性和观察者内部的再现性。Rengachary及其同事使用的分类的平均kappa值为0.468,Ticker及其同事使用的分类在缺口下边界的kappa值为0.531,在缺口上边界的kappa值为0.736。Ticker及其同事使用的分类系统更加可靠和可重复性,并产生了优劣分类,使其可能比Rengachary及其同事使用的分类系统更具临床相关性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Interobserver reliability and intraobserver reproducibility in suprascapular notch typing.

The size and shape of the suprascapular notch may be a factor in suprascapular nerve entrapment. The suprascapular notches of 623 scapulae were digitally photographed and used to determine notch type and area. Three researchers used to different classification systems for suprascapular notch typing. These systems were compared for interobserver reliability and intraobserver reproducibility using the kappa test. The mean kappa value for the classification used by Rengachary and colleagues was 0.468 and for the classification used by Ticker and associates was 0.531 for the inferior border of the notch and 0.736 for the superior border of the notch. The classification system used by Ticker and associates was more reliable and reproducible and produced both a superior and an inferior classification, making it possibly more clinically relevant than the classification system used by Rengachary and colleagues.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信