Kwang Cheol Koh, Hong Joo Kim, Won Hyeok Choe, Gyung Soo Chae, Moon Seok Choi, Joon Hyoek Lee, Seung Woon Paik, Jong Chul Rhee, Kyu Wan Choi
{"title":"[SPIO-MRI在肝细胞癌检测及分期中的临床应用]。","authors":"Kwang Cheol Koh, Hong Joo Kim, Won Hyeok Choe, Gyung Soo Chae, Moon Seok Choi, Joon Hyoek Lee, Seung Woon Paik, Jong Chul Rhee, Kyu Wan Choi","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Background/aims: </strong>It is still unclear whether Super Paramagnetic Iron Oxide-Magnetic Resonance Imaging (SPIO-MRI) is a clinically useful imaging modality for patients with hepatocellular carcinoma (HCC). This study searched for the clinical usefulness and limitations of SPIO-MRI with respect to tumor detection capacity, false positive and negative rate, and early recurrence rate.</p><p><strong>Methods: </strong>From December 1999 to February 2001, 218 patients who were surgical candidates by 3-phase dynamic helical CT (3dHCT) were enrolled. We reviewed the medical records and radiologic findings, retrospectively, and postulated the post-operative pathologic findings and the early recurrences within 3 months as the standards for the true positive lesion.</p><p><strong>Results: </strong>The mean number of nodules detected by SPIO-MRI was significantly more numerous than that of 3dHCT (p<0.01). Modifications of treatment strategy due to the discordant findings between SPIO-MRI and 3dHCT for tumor resectability were observed in 22 (10.1%) out of 218 patients. Early recurrences were observed in 10 patients (7.8%). The false positive and negative rates of SPIO-MRI were 6.3% and 13.3%, respectively.</p><p><strong>Conclusions: </strong>We demonstrated that the tumor detection rate of SPIO-MRI was better than that of 3dHCT. Given the relatively acceptable false positive and negative rates, SPIO-MRI could be an appropriate preoperative imaging modality for patients with HCCs.</p>","PeriodicalId":85610,"journal":{"name":"Taehan Kan Hakhoe chi = The Korean journal of hepatology","volume":"9 1","pages":"17-24"},"PeriodicalIF":0.0000,"publicationDate":"2003-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[The clinical usefulness of SPIO-MRI in detection and staging of hepatocellular carcinoma].\",\"authors\":\"Kwang Cheol Koh, Hong Joo Kim, Won Hyeok Choe, Gyung Soo Chae, Moon Seok Choi, Joon Hyoek Lee, Seung Woon Paik, Jong Chul Rhee, Kyu Wan Choi\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Background/aims: </strong>It is still unclear whether Super Paramagnetic Iron Oxide-Magnetic Resonance Imaging (SPIO-MRI) is a clinically useful imaging modality for patients with hepatocellular carcinoma (HCC). This study searched for the clinical usefulness and limitations of SPIO-MRI with respect to tumor detection capacity, false positive and negative rate, and early recurrence rate.</p><p><strong>Methods: </strong>From December 1999 to February 2001, 218 patients who were surgical candidates by 3-phase dynamic helical CT (3dHCT) were enrolled. We reviewed the medical records and radiologic findings, retrospectively, and postulated the post-operative pathologic findings and the early recurrences within 3 months as the standards for the true positive lesion.</p><p><strong>Results: </strong>The mean number of nodules detected by SPIO-MRI was significantly more numerous than that of 3dHCT (p<0.01). Modifications of treatment strategy due to the discordant findings between SPIO-MRI and 3dHCT for tumor resectability were observed in 22 (10.1%) out of 218 patients. Early recurrences were observed in 10 patients (7.8%). The false positive and negative rates of SPIO-MRI were 6.3% and 13.3%, respectively.</p><p><strong>Conclusions: </strong>We demonstrated that the tumor detection rate of SPIO-MRI was better than that of 3dHCT. Given the relatively acceptable false positive and negative rates, SPIO-MRI could be an appropriate preoperative imaging modality for patients with HCCs.</p>\",\"PeriodicalId\":85610,\"journal\":{\"name\":\"Taehan Kan Hakhoe chi = The Korean journal of hepatology\",\"volume\":\"9 1\",\"pages\":\"17-24\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2003-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Taehan Kan Hakhoe chi = The Korean journal of hepatology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Taehan Kan Hakhoe chi = The Korean journal of hepatology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
[The clinical usefulness of SPIO-MRI in detection and staging of hepatocellular carcinoma].
Background/aims: It is still unclear whether Super Paramagnetic Iron Oxide-Magnetic Resonance Imaging (SPIO-MRI) is a clinically useful imaging modality for patients with hepatocellular carcinoma (HCC). This study searched for the clinical usefulness and limitations of SPIO-MRI with respect to tumor detection capacity, false positive and negative rate, and early recurrence rate.
Methods: From December 1999 to February 2001, 218 patients who were surgical candidates by 3-phase dynamic helical CT (3dHCT) were enrolled. We reviewed the medical records and radiologic findings, retrospectively, and postulated the post-operative pathologic findings and the early recurrences within 3 months as the standards for the true positive lesion.
Results: The mean number of nodules detected by SPIO-MRI was significantly more numerous than that of 3dHCT (p<0.01). Modifications of treatment strategy due to the discordant findings between SPIO-MRI and 3dHCT for tumor resectability were observed in 22 (10.1%) out of 218 patients. Early recurrences were observed in 10 patients (7.8%). The false positive and negative rates of SPIO-MRI were 6.3% and 13.3%, respectively.
Conclusions: We demonstrated that the tumor detection rate of SPIO-MRI was better than that of 3dHCT. Given the relatively acceptable false positive and negative rates, SPIO-MRI could be an appropriate preoperative imaging modality for patients with HCCs.