感音神经性听力损失(SNHL)纯音阈值的解释:测量变异性和年龄特异性参考文献的回顾。

IF 0.2 4区 医学 Q3 Medicine
B-Ent Pub Date : 2002-01-01
N Lemkens, K Vermeire, J P L Brokx, E Fransen, G Van Camp, P H Van De Heyning
{"title":"感音神经性听力损失(SNHL)纯音阈值的解释:测量变异性和年龄特异性参考文献的回顾。","authors":"N Lemkens,&nbsp;K Vermeire,&nbsp;J P L Brokx,&nbsp;E Fransen,&nbsp;G Van Camp,&nbsp;P H Van De Heyning","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>When assessing a patient with a sensorineural hearing impairment, the most simple and most widely available technical investigation is pure-tone audiometry. Although it is a subjective measure, the test is very reliable if the patient is cooperative. In this paper we review standards and test-retest reliability for pure-tone audiometry. A pure-tone threshold measurement at a single frequency has a chance of 90% to be repeated between -10 dB and +10 dB compared to the first measurement, assuming no real change in hearing thresholds has occurred. It is also of great importance to use correct gender- and age-specific reference values when interpreting pure-tone threshold measurements. Several large-scale epidemiological studies have been conducted during recent years, and have provided us with reliable gender- and age-specific references. A method to take into account the age-related deterioration is presented. In this method, Z-score audiograms represent traditional thresholds in an age- and gender-independent way. At each frequency, the Z-score value is the number of standard deviation units that the threshold differs from the median value for the otologically normal population (ISO 7029).</p>","PeriodicalId":55407,"journal":{"name":"B-Ent","volume":"56 4","pages":"341-52"},"PeriodicalIF":0.2000,"publicationDate":"2002-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Interpretation of pure-tone thresholds in sensorineural hearing loss (SNHL): a review of measurement variability and age-specific references.\",\"authors\":\"N Lemkens,&nbsp;K Vermeire,&nbsp;J P L Brokx,&nbsp;E Fransen,&nbsp;G Van Camp,&nbsp;P H Van De Heyning\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>When assessing a patient with a sensorineural hearing impairment, the most simple and most widely available technical investigation is pure-tone audiometry. Although it is a subjective measure, the test is very reliable if the patient is cooperative. In this paper we review standards and test-retest reliability for pure-tone audiometry. A pure-tone threshold measurement at a single frequency has a chance of 90% to be repeated between -10 dB and +10 dB compared to the first measurement, assuming no real change in hearing thresholds has occurred. It is also of great importance to use correct gender- and age-specific reference values when interpreting pure-tone threshold measurements. Several large-scale epidemiological studies have been conducted during recent years, and have provided us with reliable gender- and age-specific references. A method to take into account the age-related deterioration is presented. In this method, Z-score audiograms represent traditional thresholds in an age- and gender-independent way. At each frequency, the Z-score value is the number of standard deviation units that the threshold differs from the median value for the otologically normal population (ISO 7029).</p>\",\"PeriodicalId\":55407,\"journal\":{\"name\":\"B-Ent\",\"volume\":\"56 4\",\"pages\":\"341-52\"},\"PeriodicalIF\":0.2000,\"publicationDate\":\"2002-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"B-Ent\",\"FirstCategoryId\":\"3\",\"ListUrlMain\":\"\",\"RegionNum\":4,\"RegionCategory\":\"医学\",\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"Q3\",\"JCRName\":\"Medicine\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"B-Ent","FirstCategoryId":"3","ListUrlMain":"","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

摘要

在评估感音神经性听力障碍患者时,最简单和最广泛使用的技术调查是纯音听力测定。虽然这是一种主观测量,但如果患者配合,测试是非常可靠的。本文综述了纯音测听的标准和重测信度。假设听力阈值没有发生真正的变化,与第一次测量相比,单一频率的纯音阈值测量在-10 dB和+10 dB之间有90%的机会重复。在解释纯音阈值测量时,使用正确的性别和年龄特定参考值也非常重要。近年来进行了几次大规模流行病学研究,为我们提供了可靠的特定性别和年龄参考资料。提出了一种考虑与年龄相关的退化的方法。在这种方法中,z分数听力图以年龄和性别无关的方式代表传统的阈值。在每个频率下,z得分值是阈值与耳正常人群(ISO 7029)的中位数不同的标准差单位数。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Interpretation of pure-tone thresholds in sensorineural hearing loss (SNHL): a review of measurement variability and age-specific references.

When assessing a patient with a sensorineural hearing impairment, the most simple and most widely available technical investigation is pure-tone audiometry. Although it is a subjective measure, the test is very reliable if the patient is cooperative. In this paper we review standards and test-retest reliability for pure-tone audiometry. A pure-tone threshold measurement at a single frequency has a chance of 90% to be repeated between -10 dB and +10 dB compared to the first measurement, assuming no real change in hearing thresholds has occurred. It is also of great importance to use correct gender- and age-specific reference values when interpreting pure-tone threshold measurements. Several large-scale epidemiological studies have been conducted during recent years, and have provided us with reliable gender- and age-specific references. A method to take into account the age-related deterioration is presented. In this method, Z-score audiograms represent traditional thresholds in an age- and gender-independent way. At each frequency, the Z-score value is the number of standard deviation units that the threshold differs from the median value for the otologically normal population (ISO 7029).

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
B-Ent
B-Ent 医学-耳鼻喉科学
CiteScore
0.60
自引率
0.00%
发文量
2
审稿时长
6-12 weeks
期刊介绍: Throughout its history, the Royal Belgian Society of Oto-rhino-laryngology, Head and Neck Surgery, the home society of B-ENT, aims to disseminate both the scientific and the clinical knowledge of otorhinolaryngology field primarily in Belgium and its regions. In accordance with this aim, publishing a scientific journal has become the number one objective of the Society. Accordingly, B-ENT contributes to the scientific memory of Belgium considering its deep-rooted history.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信