D M Albala, T M Turk, B R Fulmer, F Koleski, G Andriole, B E Davis, G R Eure, J N Kabalin, J Lingeman, J Nuzzarello, C Sundaram
{"title":"经尿道微波热疗法治疗良性前列腺增生:使用热基质TMx-2000的1年中期安全性和有效性分析","authors":"D M Albala, T M Turk, B R Fulmer, F Koleski, G Andriole, B E Davis, G R Eure, J N Kabalin, J Lingeman, J Nuzzarello, C Sundaram","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Transurethral microwave thermotherapy (TUMT) represents an accepted minimally invasive approach to the management of patients with benign prostatic hyperplasia (BPH). The TherMatrx TMx-2000 represents a further evolution in TUMT technique. This device uses periurethral transurethral microwave thermotherapy (P-TUMT) technology to directly target the BPH tissue adjacent to the prostatic urethra by using a catheter without a urethral-cooling surface. This article provides a technical review of the device and describes the results of a randomized, controlled multicenter study of P-TUMT for the treatment of symptomatic BPH. A discussion of the physiologic effects of P-TUMT is presented and compared to conventional TUMT. A comparison of P-TUMT to contemporary TUMT series in relation to efficacy and complications is also described. This study concludes that P-TUMT using the TherMatrx TMx-2000 device represents a minimally invasive, efficacious, and well-tolerated treatment for symptomatic BPH.</p>","PeriodicalId":79536,"journal":{"name":"Techniques in urology","volume":"6 4","pages":"288-93"},"PeriodicalIF":0.0000,"publicationDate":"2000-12-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Periurethral transurethral microwave thermotherapy for the treatment of benign prostatic hyperplasia: an interim 1-year safety and efficacy analysis using the thermatrx TMx-2000.\",\"authors\":\"D M Albala, T M Turk, B R Fulmer, F Koleski, G Andriole, B E Davis, G R Eure, J N Kabalin, J Lingeman, J Nuzzarello, C Sundaram\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Transurethral microwave thermotherapy (TUMT) represents an accepted minimally invasive approach to the management of patients with benign prostatic hyperplasia (BPH). The TherMatrx TMx-2000 represents a further evolution in TUMT technique. This device uses periurethral transurethral microwave thermotherapy (P-TUMT) technology to directly target the BPH tissue adjacent to the prostatic urethra by using a catheter without a urethral-cooling surface. This article provides a technical review of the device and describes the results of a randomized, controlled multicenter study of P-TUMT for the treatment of symptomatic BPH. A discussion of the physiologic effects of P-TUMT is presented and compared to conventional TUMT. A comparison of P-TUMT to contemporary TUMT series in relation to efficacy and complications is also described. This study concludes that P-TUMT using the TherMatrx TMx-2000 device represents a minimally invasive, efficacious, and well-tolerated treatment for symptomatic BPH.</p>\",\"PeriodicalId\":79536,\"journal\":{\"name\":\"Techniques in urology\",\"volume\":\"6 4\",\"pages\":\"288-93\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-12-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Techniques in urology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Techniques in urology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Periurethral transurethral microwave thermotherapy for the treatment of benign prostatic hyperplasia: an interim 1-year safety and efficacy analysis using the thermatrx TMx-2000.
Transurethral microwave thermotherapy (TUMT) represents an accepted minimally invasive approach to the management of patients with benign prostatic hyperplasia (BPH). The TherMatrx TMx-2000 represents a further evolution in TUMT technique. This device uses periurethral transurethral microwave thermotherapy (P-TUMT) technology to directly target the BPH tissue adjacent to the prostatic urethra by using a catheter without a urethral-cooling surface. This article provides a technical review of the device and describes the results of a randomized, controlled multicenter study of P-TUMT for the treatment of symptomatic BPH. A discussion of the physiologic effects of P-TUMT is presented and compared to conventional TUMT. A comparison of P-TUMT to contemporary TUMT series in relation to efficacy and complications is also described. This study concludes that P-TUMT using the TherMatrx TMx-2000 device represents a minimally invasive, efficacious, and well-tolerated treatment for symptomatic BPH.