van Der Giessen WJ, van Beusekom HM, Larsson, Serruys
{"title":"肝素涂层冠状动脉支架。","authors":"van Der Giessen WJ, van Beusekom HM, Larsson, Serruys","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The development of the heparin-coated (HC)-stent should be viewed against the backdrop of the early unfavorable results with noncoated stents in the pre-intravascular ultrasound and pre-ticlopidine era. Notwithstanding, results of pilot and randomized trials show a surprisingly low incidence of (sub)acute stent thrombosis under challenging circumstances, such as acute coronary syndromes. Considering the quite low incidence of early complications with noncoated second-generation stents, it may require large trials to prove the clinical efficacy of the heparin- coating against noncoated devices. However, even if the \"added value\" of the heparin-coating will never be clinically proven, it has helped to enhance the penetration of stent therapy in interventional cardiology. Unlike the situation in 1992, very few cardiologists will now disagree with the statement that stents contribute to the state-of-the-art treatment of patients with angina pectoris or acute myocardial infarction. A preliminary comparison of available trials also suggests that the heparin-coated Palmaz-Schatz stent (Cordis Corp., Waterloo, Belgium) is as effective as the noncoated stent plus abciximab treatment.</p>","PeriodicalId":80270,"journal":{"name":"Current interventional cardiology reports","volume":"1 3","pages":"234-240"},"PeriodicalIF":0.0000,"publicationDate":"1999-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Heparin-Coated Coronary Stents.\",\"authors\":\"van Der Giessen WJ, van Beusekom HM, Larsson, Serruys\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The development of the heparin-coated (HC)-stent should be viewed against the backdrop of the early unfavorable results with noncoated stents in the pre-intravascular ultrasound and pre-ticlopidine era. Notwithstanding, results of pilot and randomized trials show a surprisingly low incidence of (sub)acute stent thrombosis under challenging circumstances, such as acute coronary syndromes. Considering the quite low incidence of early complications with noncoated second-generation stents, it may require large trials to prove the clinical efficacy of the heparin- coating against noncoated devices. However, even if the \\\"added value\\\" of the heparin-coating will never be clinically proven, it has helped to enhance the penetration of stent therapy in interventional cardiology. Unlike the situation in 1992, very few cardiologists will now disagree with the statement that stents contribute to the state-of-the-art treatment of patients with angina pectoris or acute myocardial infarction. A preliminary comparison of available trials also suggests that the heparin-coated Palmaz-Schatz stent (Cordis Corp., Waterloo, Belgium) is as effective as the noncoated stent plus abciximab treatment.</p>\",\"PeriodicalId\":80270,\"journal\":{\"name\":\"Current interventional cardiology reports\",\"volume\":\"1 3\",\"pages\":\"234-240\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Current interventional cardiology reports\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Current interventional cardiology reports","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The development of the heparin-coated (HC)-stent should be viewed against the backdrop of the early unfavorable results with noncoated stents in the pre-intravascular ultrasound and pre-ticlopidine era. Notwithstanding, results of pilot and randomized trials show a surprisingly low incidence of (sub)acute stent thrombosis under challenging circumstances, such as acute coronary syndromes. Considering the quite low incidence of early complications with noncoated second-generation stents, it may require large trials to prove the clinical efficacy of the heparin- coating against noncoated devices. However, even if the "added value" of the heparin-coating will never be clinically proven, it has helped to enhance the penetration of stent therapy in interventional cardiology. Unlike the situation in 1992, very few cardiologists will now disagree with the statement that stents contribute to the state-of-the-art treatment of patients with angina pectoris or acute myocardial infarction. A preliminary comparison of available trials also suggests that the heparin-coated Palmaz-Schatz stent (Cordis Corp., Waterloo, Belgium) is as effective as the noncoated stent plus abciximab treatment.