样本量对噪声本底和DPOAE可靠性的影响。

R C Beattie, J Bleech
{"title":"样本量对噪声本底和DPOAE可靠性的影响。","authors":"R C Beattie,&nbsp;J Bleech","doi":"10.3109/03005364000000142","DOIUrl":null,"url":null,"abstract":"<p><p>This study investigated the effects of sample size on the test-retest reliability of the amplitude of distortion product otoacoustic emissions (DPOAE) (2f1-f2) and on the noise floor. Four pairs of primary frequencies (fl and f2) with geometric means of 531, 1000, 2000 and 4000 Hz were presented to 55 normal-hearing women at intensity levels of 35, 45 and 55 dB SPL (L1 = L2). Sample sizes of 12, 25, 50, 100, 200 and 400 sweeps were averaged. The results revealed that sample size, frequency, and intensity had little effect on the standard error of measurement. Thus, the DPOAE data were combined across all conditions and yielded a standard error of measurement of 2.2 dB. To assess whether two DPOAE measurements are statistically significant (e.g. before and after drug administration), the standard error of measurement of the difference between two values was calculated (3.1 dB). Thus, by use of the 95% confidence interval, the difference between two DPOAE is statistically significant if it exceeds approximately 6 dB.</p>","PeriodicalId":75616,"journal":{"name":"British journal of audiology","volume":"34 5","pages":"305-9"},"PeriodicalIF":0.0000,"publicationDate":"2000-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/03005364000000142","citationCount":"31","resultStr":"{\"title\":\"Effects of sample size on the reliability of noise floor and DPOAE.\",\"authors\":\"R C Beattie,&nbsp;J Bleech\",\"doi\":\"10.3109/03005364000000142\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study investigated the effects of sample size on the test-retest reliability of the amplitude of distortion product otoacoustic emissions (DPOAE) (2f1-f2) and on the noise floor. Four pairs of primary frequencies (fl and f2) with geometric means of 531, 1000, 2000 and 4000 Hz were presented to 55 normal-hearing women at intensity levels of 35, 45 and 55 dB SPL (L1 = L2). Sample sizes of 12, 25, 50, 100, 200 and 400 sweeps were averaged. The results revealed that sample size, frequency, and intensity had little effect on the standard error of measurement. Thus, the DPOAE data were combined across all conditions and yielded a standard error of measurement of 2.2 dB. To assess whether two DPOAE measurements are statistically significant (e.g. before and after drug administration), the standard error of measurement of the difference between two values was calculated (3.1 dB). Thus, by use of the 95% confidence interval, the difference between two DPOAE is statistically significant if it exceeds approximately 6 dB.</p>\",\"PeriodicalId\":75616,\"journal\":{\"name\":\"British journal of audiology\",\"volume\":\"34 5\",\"pages\":\"305-9\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.3109/03005364000000142\",\"citationCount\":\"31\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"British journal of audiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3109/03005364000000142\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"British journal of audiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/03005364000000142","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 31

摘要

本研究探讨了样本量对失真积耳声发射(DPOAE) (2f1-f2)的重测信度和噪声底的影响。在35、45和55 dB SPL (L1 = L2)的强度水平下,向55名正常听力女性呈现4对主要频率(fl和f2),几何平均值分别为531、1000、2000和4000 Hz。样本大小分别为12、25、50、100、200和400次。结果表明,样本量、频率和强度对测量的标准误差影响不大。因此,DPOAE数据在所有条件下组合,并产生2.2 dB的测量标准误差。为了评估两次DPOAE测量值是否具有统计学意义(如给药前后),计算两次测量值差异的标准误差(3.1 dB)。因此,通过使用95%置信区间,如果两个DPOAE之间的差异超过大约6 dB,则具有统计学意义。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effects of sample size on the reliability of noise floor and DPOAE.

This study investigated the effects of sample size on the test-retest reliability of the amplitude of distortion product otoacoustic emissions (DPOAE) (2f1-f2) and on the noise floor. Four pairs of primary frequencies (fl and f2) with geometric means of 531, 1000, 2000 and 4000 Hz were presented to 55 normal-hearing women at intensity levels of 35, 45 and 55 dB SPL (L1 = L2). Sample sizes of 12, 25, 50, 100, 200 and 400 sweeps were averaged. The results revealed that sample size, frequency, and intensity had little effect on the standard error of measurement. Thus, the DPOAE data were combined across all conditions and yielded a standard error of measurement of 2.2 dB. To assess whether two DPOAE measurements are statistically significant (e.g. before and after drug administration), the standard error of measurement of the difference between two values was calculated (3.1 dB). Thus, by use of the 95% confidence interval, the difference between two DPOAE is statistically significant if it exceeds approximately 6 dB.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信