使用手持式眼底相机进行糖尿病视网膜病变的远程医疗筛查。

K Yogesan, I J Constable, C J Barry, R H Eikelboom, I L McAllister, M L Tay-Kearney
{"title":"使用手持式眼底相机进行糖尿病视网膜病变的远程医疗筛查。","authors":"K Yogesan,&nbsp;I J Constable,&nbsp;C J Barry,&nbsp;R H Eikelboom,&nbsp;I L McAllister,&nbsp;M L Tay-Kearney","doi":"10.1089/107830200415153","DOIUrl":null,"url":null,"abstract":"<p><p>The objective was to evaluate digital images of the retina from a handheld fundus camera (Nidek NM-100) for suitability in telemedicine screening of diabetic retinopathy. A handheld fundus camera (Nidek) and a standard fundus camera (Zeiss) were used to photograph 49 eyes from 25 consecutive patients attending our diabetic clinic. One patient had cataracts, making it impossible to get a quality image of one of the eyes (retina). The Nidek images were digitized, compressed, and stored in a Fujix DF-10M digitizer supplied with the camera. The digital images and the photographs were presented separately in a random order to three ophthalmologists. The quality of the images was ranked as good, acceptable or unacceptable for diabetic retinopathy diagnosis. The images were also evaluated for the presence of microaneurysms, blot hemorrhages, exudates, fibrous tissue, previous photocoagulation, and new vessel formation. kappa Values were computed for agreement between the photographs and digital images. Overall agreement between the photographs and digital images was poor (kappa < 0.30). On average, only 24% of the digital images were graded as being good quality and 56% as having an acceptable quality. However, 93% of the photographs were graded as good-quality images for diagnosis. The results indicate that the digital images from the handheld fundus camera may not be suitable for diagnosis of diabetic retinopathy. The images shown on the liquid crystal display (LCD) screen of the camera were of good quality. However, the images produced by the digitizer (Fujix DF-10M) attached to the camera were not as good as the images shown on the LCD screen. A better digitizing system may produce better quality images from the Nidek camera.</p>","PeriodicalId":79734,"journal":{"name":"Telemedicine journal : the official journal of the American Telemedicine Association","volume":"6 2","pages":"219-23"},"PeriodicalIF":0.0000,"publicationDate":"2000-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1089/107830200415153","citationCount":"52","resultStr":"{\"title\":\"Telemedicine screening of diabetic retinopathy using a hand-held fundus camera.\",\"authors\":\"K Yogesan,&nbsp;I J Constable,&nbsp;C J Barry,&nbsp;R H Eikelboom,&nbsp;I L McAllister,&nbsp;M L Tay-Kearney\",\"doi\":\"10.1089/107830200415153\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The objective was to evaluate digital images of the retina from a handheld fundus camera (Nidek NM-100) for suitability in telemedicine screening of diabetic retinopathy. A handheld fundus camera (Nidek) and a standard fundus camera (Zeiss) were used to photograph 49 eyes from 25 consecutive patients attending our diabetic clinic. One patient had cataracts, making it impossible to get a quality image of one of the eyes (retina). The Nidek images were digitized, compressed, and stored in a Fujix DF-10M digitizer supplied with the camera. The digital images and the photographs were presented separately in a random order to three ophthalmologists. The quality of the images was ranked as good, acceptable or unacceptable for diabetic retinopathy diagnosis. The images were also evaluated for the presence of microaneurysms, blot hemorrhages, exudates, fibrous tissue, previous photocoagulation, and new vessel formation. kappa Values were computed for agreement between the photographs and digital images. Overall agreement between the photographs and digital images was poor (kappa < 0.30). On average, only 24% of the digital images were graded as being good quality and 56% as having an acceptable quality. However, 93% of the photographs were graded as good-quality images for diagnosis. The results indicate that the digital images from the handheld fundus camera may not be suitable for diagnosis of diabetic retinopathy. The images shown on the liquid crystal display (LCD) screen of the camera were of good quality. However, the images produced by the digitizer (Fujix DF-10M) attached to the camera were not as good as the images shown on the LCD screen. A better digitizing system may produce better quality images from the Nidek camera.</p>\",\"PeriodicalId\":79734,\"journal\":{\"name\":\"Telemedicine journal : the official journal of the American Telemedicine Association\",\"volume\":\"6 2\",\"pages\":\"219-23\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1089/107830200415153\",\"citationCount\":\"52\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Telemedicine journal : the official journal of the American Telemedicine Association\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1089/107830200415153\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Telemedicine journal : the official journal of the American Telemedicine Association","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1089/107830200415153","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 52

摘要

目的是评估来自手持式眼底相机(Nidek NM-100)的视网膜数字图像在糖尿病视网膜病变远程医疗筛查中的适用性。使用手持式眼底相机(Nidek)和标准眼底相机(蔡司)对25例连续就诊的糖尿病患者的49只眼睛进行了拍摄。一名患者患有白内障,无法获得一只眼睛(视网膜)的高质量图像。Nidek图像被数字化、压缩并存储在相机附带的富士DF-10M数字化仪中。数字图像和照片分别以随机顺序呈现给三位眼科医生。图像质量被评为良好,可接受或不可接受的糖尿病视网膜病变诊断。同时评估图像是否存在微动脉瘤、出血、渗出、纤维组织、既往光凝和新血管形成。kappa值计算照片和数字图像之间的一致性。照片和数字图像之间的总体一致性较差(kappa < 0.30)。平均而言,只有24%的数字图像被评为质量良好,56%的数字图像被评为质量尚可。然而,93%的照片被评为诊断质量良好的图像。结果表明,手持式眼底相机的数字图像可能不适合诊断糖尿病视网膜病变。相机的液晶显示器(LCD)屏幕显示的图像质量良好。但是,相机附带的数字化仪(富士DF-10M)所产生的图像不如LCD屏幕显示的图像好。一个更好的数字化系统可以从Nidek相机产生更好质量的图像。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Telemedicine screening of diabetic retinopathy using a hand-held fundus camera.

The objective was to evaluate digital images of the retina from a handheld fundus camera (Nidek NM-100) for suitability in telemedicine screening of diabetic retinopathy. A handheld fundus camera (Nidek) and a standard fundus camera (Zeiss) were used to photograph 49 eyes from 25 consecutive patients attending our diabetic clinic. One patient had cataracts, making it impossible to get a quality image of one of the eyes (retina). The Nidek images were digitized, compressed, and stored in a Fujix DF-10M digitizer supplied with the camera. The digital images and the photographs were presented separately in a random order to three ophthalmologists. The quality of the images was ranked as good, acceptable or unacceptable for diabetic retinopathy diagnosis. The images were also evaluated for the presence of microaneurysms, blot hemorrhages, exudates, fibrous tissue, previous photocoagulation, and new vessel formation. kappa Values were computed for agreement between the photographs and digital images. Overall agreement between the photographs and digital images was poor (kappa < 0.30). On average, only 24% of the digital images were graded as being good quality and 56% as having an acceptable quality. However, 93% of the photographs were graded as good-quality images for diagnosis. The results indicate that the digital images from the handheld fundus camera may not be suitable for diagnosis of diabetic retinopathy. The images shown on the liquid crystal display (LCD) screen of the camera were of good quality. However, the images produced by the digitizer (Fujix DF-10M) attached to the camera were not as good as the images shown on the LCD screen. A better digitizing system may produce better quality images from the Nidek camera.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信