S Hatzopoulos, J Cheng, A Grzanka, A Martini
{"title":"正常人和SNHL患者TEOAE记录的时频分析。","authors":"S Hatzopoulos,&nbsp;J Cheng,&nbsp;A Grzanka,&nbsp;A Martini","doi":"10.3109/00206090009073048","DOIUrl":null,"url":null,"abstract":"<p><p>This study evaluated the characteristics of transient evoked otoacoustic emission (TEOAE) time-frequency (TF) representations from normal and hearing-impaired ears. Linear and non-linear TEOAE recordings from normally-hearing subjects (40) and non-linear recordings from patients with sensorineural hearing loss (SNHL) (40) were analysed using the short-time-Fourier-transform spectrogram, the Gabor spectrogram, and the adaptive spectrogram. The TF representations of the TEOAE recordings indicated a considerable dispersion of energy across frequencies and TEOAE time segments >4.0 ms. The linear and non-linear recordings from the normal subjects showed common frequency peaks. The TF representations from the patients with SNHL indicated that the significantly reduced energy in the mid-to-high TEOAE frequencies did not correlate closely with the threshold elevation. As in the recordings from the normal subjects, a high percentage of the TEOAE cumulative energy was found within a short TEOAE segment (4-14 ms).</p>","PeriodicalId":75571,"journal":{"name":"Audiology : official organ of the International Society of Audiology","volume":"39 1","pages":"1-12"},"PeriodicalIF":0.0000,"publicationDate":"2000-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/00206090009073048","citationCount":"19","resultStr":"{\"title\":\"Time-frequency analyses of TEOAE recordings from normals and SNHL patients.\",\"authors\":\"S Hatzopoulos,&nbsp;J Cheng,&nbsp;A Grzanka,&nbsp;A Martini\",\"doi\":\"10.3109/00206090009073048\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study evaluated the characteristics of transient evoked otoacoustic emission (TEOAE) time-frequency (TF) representations from normal and hearing-impaired ears. Linear and non-linear TEOAE recordings from normally-hearing subjects (40) and non-linear recordings from patients with sensorineural hearing loss (SNHL) (40) were analysed using the short-time-Fourier-transform spectrogram, the Gabor spectrogram, and the adaptive spectrogram. The TF representations of the TEOAE recordings indicated a considerable dispersion of energy across frequencies and TEOAE time segments >4.0 ms. The linear and non-linear recordings from the normal subjects showed common frequency peaks. The TF representations from the patients with SNHL indicated that the significantly reduced energy in the mid-to-high TEOAE frequencies did not correlate closely with the threshold elevation. As in the recordings from the normal subjects, a high percentage of the TEOAE cumulative energy was found within a short TEOAE segment (4-14 ms).</p>\",\"PeriodicalId\":75571,\"journal\":{\"name\":\"Audiology : official organ of the International Society of Audiology\",\"volume\":\"39 1\",\"pages\":\"1-12\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.3109/00206090009073048\",\"citationCount\":\"19\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Audiology : official organ of the International Society of Audiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3109/00206090009073048\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Audiology : official organ of the International Society of Audiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/00206090009073048","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 19

摘要

本研究评估了正常耳和听力受损耳的瞬态诱发耳声发射(TEOAE)时频表征特征。采用短时傅立叶变换谱图、Gabor谱图和自适应谱图对正常听力受试者(40例)的线性和非线性TEOAE记录以及感音神经性听力损失患者(40例)的非线性TEOAE记录进行分析。TEOAE记录的TF表示表明能量在频率和TEOAE时间段上有相当大的色散,>4.0 ms。正常受试者的线性和非线性记录显示出共同的频率峰值。SNHL患者的TF表征表明,中高TEOAE频率的能量显著降低与阈值升高不密切相关。与正常受试者的记录一样,在较短的TEOAE段(4-14 ms)内发现了高比例的TEOAE累积能量。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Time-frequency analyses of TEOAE recordings from normals and SNHL patients.

This study evaluated the characteristics of transient evoked otoacoustic emission (TEOAE) time-frequency (TF) representations from normal and hearing-impaired ears. Linear and non-linear TEOAE recordings from normally-hearing subjects (40) and non-linear recordings from patients with sensorineural hearing loss (SNHL) (40) were analysed using the short-time-Fourier-transform spectrogram, the Gabor spectrogram, and the adaptive spectrogram. The TF representations of the TEOAE recordings indicated a considerable dispersion of energy across frequencies and TEOAE time segments >4.0 ms. The linear and non-linear recordings from the normal subjects showed common frequency peaks. The TF representations from the patients with SNHL indicated that the significantly reduced energy in the mid-to-high TEOAE frequencies did not correlate closely with the threshold elevation. As in the recordings from the normal subjects, a high percentage of the TEOAE cumulative energy was found within a short TEOAE segment (4-14 ms).

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信