{"title":"正常人和SNHL患者TEOAE记录的时频分析。","authors":"S Hatzopoulos, J Cheng, A Grzanka, A Martini","doi":"10.3109/00206090009073048","DOIUrl":null,"url":null,"abstract":"<p><p>This study evaluated the characteristics of transient evoked otoacoustic emission (TEOAE) time-frequency (TF) representations from normal and hearing-impaired ears. Linear and non-linear TEOAE recordings from normally-hearing subjects (40) and non-linear recordings from patients with sensorineural hearing loss (SNHL) (40) were analysed using the short-time-Fourier-transform spectrogram, the Gabor spectrogram, and the adaptive spectrogram. The TF representations of the TEOAE recordings indicated a considerable dispersion of energy across frequencies and TEOAE time segments >4.0 ms. The linear and non-linear recordings from the normal subjects showed common frequency peaks. The TF representations from the patients with SNHL indicated that the significantly reduced energy in the mid-to-high TEOAE frequencies did not correlate closely with the threshold elevation. As in the recordings from the normal subjects, a high percentage of the TEOAE cumulative energy was found within a short TEOAE segment (4-14 ms).</p>","PeriodicalId":75571,"journal":{"name":"Audiology : official organ of the International Society of Audiology","volume":"39 1","pages":"1-12"},"PeriodicalIF":0.0000,"publicationDate":"2000-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/00206090009073048","citationCount":"19","resultStr":"{\"title\":\"Time-frequency analyses of TEOAE recordings from normals and SNHL patients.\",\"authors\":\"S Hatzopoulos, J Cheng, A Grzanka, A Martini\",\"doi\":\"10.3109/00206090009073048\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This study evaluated the characteristics of transient evoked otoacoustic emission (TEOAE) time-frequency (TF) representations from normal and hearing-impaired ears. Linear and non-linear TEOAE recordings from normally-hearing subjects (40) and non-linear recordings from patients with sensorineural hearing loss (SNHL) (40) were analysed using the short-time-Fourier-transform spectrogram, the Gabor spectrogram, and the adaptive spectrogram. The TF representations of the TEOAE recordings indicated a considerable dispersion of energy across frequencies and TEOAE time segments >4.0 ms. The linear and non-linear recordings from the normal subjects showed common frequency peaks. The TF representations from the patients with SNHL indicated that the significantly reduced energy in the mid-to-high TEOAE frequencies did not correlate closely with the threshold elevation. As in the recordings from the normal subjects, a high percentage of the TEOAE cumulative energy was found within a short TEOAE segment (4-14 ms).</p>\",\"PeriodicalId\":75571,\"journal\":{\"name\":\"Audiology : official organ of the International Society of Audiology\",\"volume\":\"39 1\",\"pages\":\"1-12\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"2000-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.3109/00206090009073048\",\"citationCount\":\"19\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Audiology : official organ of the International Society of Audiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3109/00206090009073048\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Audiology : official organ of the International Society of Audiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/00206090009073048","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Time-frequency analyses of TEOAE recordings from normals and SNHL patients.
This study evaluated the characteristics of transient evoked otoacoustic emission (TEOAE) time-frequency (TF) representations from normal and hearing-impaired ears. Linear and non-linear TEOAE recordings from normally-hearing subjects (40) and non-linear recordings from patients with sensorineural hearing loss (SNHL) (40) were analysed using the short-time-Fourier-transform spectrogram, the Gabor spectrogram, and the adaptive spectrogram. The TF representations of the TEOAE recordings indicated a considerable dispersion of energy across frequencies and TEOAE time segments >4.0 ms. The linear and non-linear recordings from the normal subjects showed common frequency peaks. The TF representations from the patients with SNHL indicated that the significantly reduced energy in the mid-to-high TEOAE frequencies did not correlate closely with the threshold elevation. As in the recordings from the normal subjects, a high percentage of the TEOAE cumulative energy was found within a short TEOAE segment (4-14 ms).