[自动酶联荧光法检测风疹病毒血清特异性IgG抗体的实验室评价]。

T C Hou, W K Huang, Y C Liu
{"title":"[自动酶联荧光法检测风疹病毒血清特异性IgG抗体的实验室评价]。","authors":"T C Hou,&nbsp;W K Huang,&nbsp;Y C Liu","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The VIDAS rubella IgG(RBG) is a new, automated, enzyme-linkad fluorescent assay(ELFA) for detecting IgG antibodies to rubella virus in serum. The purpose of this study was to evaluate the usefulness of the qualitative and quantitative VIDAS RBG as laboratory tests in the rapid detecting anti-rubella IgG antibodies. Simultaneous parallel testing was performed by using the qualitative and quantitative RBG along with RUBAZYME(ABBOTT LABORATORIES) and the standard hemagglutination-inhibition(HI) test(R-HI kit, SEIKEN) on 200 blood samples submitted for anti-rubella IgG antibodies testing from patients at the VGH-Kaohsiung(Mar.-Sep., 1993). The qualitative and quantitative VIDAS RBG and RUBAZYME assay were compared to the standard R-HI test. Significant differences among the sensitivities of these three methods were found (100% sensitivity for the qualitative VIDAS RBG, 88.89% for the quantitative VIDAS RBG and 97.67% for the RUBAZYME). However, the specificities of these three methods were all the same, 100%. With these results we can conclude that the qualitative VIDAS RBG will provide a very good, precise and reliable method to determine serum specific IgG antibodies against rubella virus. Furthermore, the VIDAS RBG is fully automated and time-saving procedures (for every batch of test, it takes 25 minutes with VIDAS RBG, 2.5 hours with RUBAZYME and 4.5 hours with R-HI) in clinical laboratories.</p>","PeriodicalId":24009,"journal":{"name":"Zhonghua Minguo wei sheng wu ji mian yi xue za zhi = Chinese journal of microbiology and immunology","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1996-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Laboratory evaluation of automated enzyme linked fluorescent assay for detecting serum specific IgG antibodies against rubella virus].\",\"authors\":\"T C Hou,&nbsp;W K Huang,&nbsp;Y C Liu\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The VIDAS rubella IgG(RBG) is a new, automated, enzyme-linkad fluorescent assay(ELFA) for detecting IgG antibodies to rubella virus in serum. The purpose of this study was to evaluate the usefulness of the qualitative and quantitative VIDAS RBG as laboratory tests in the rapid detecting anti-rubella IgG antibodies. Simultaneous parallel testing was performed by using the qualitative and quantitative RBG along with RUBAZYME(ABBOTT LABORATORIES) and the standard hemagglutination-inhibition(HI) test(R-HI kit, SEIKEN) on 200 blood samples submitted for anti-rubella IgG antibodies testing from patients at the VGH-Kaohsiung(Mar.-Sep., 1993). The qualitative and quantitative VIDAS RBG and RUBAZYME assay were compared to the standard R-HI test. Significant differences among the sensitivities of these three methods were found (100% sensitivity for the qualitative VIDAS RBG, 88.89% for the quantitative VIDAS RBG and 97.67% for the RUBAZYME). However, the specificities of these three methods were all the same, 100%. With these results we can conclude that the qualitative VIDAS RBG will provide a very good, precise and reliable method to determine serum specific IgG antibodies against rubella virus. Furthermore, the VIDAS RBG is fully automated and time-saving procedures (for every batch of test, it takes 25 minutes with VIDAS RBG, 2.5 hours with RUBAZYME and 4.5 hours with R-HI) in clinical laboratories.</p>\",\"PeriodicalId\":24009,\"journal\":{\"name\":\"Zhonghua Minguo wei sheng wu ji mian yi xue za zhi = Chinese journal of microbiology and immunology\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1996-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Zhonghua Minguo wei sheng wu ji mian yi xue za zhi = Chinese journal of microbiology and immunology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zhonghua Minguo wei sheng wu ji mian yi xue za zhi = Chinese journal of microbiology and immunology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

VIDAS风疹IgG(RBG)是一种新的、自动化的酶联荧光法(ELFA),用于检测血清中风疹病毒IgG抗体。本研究的目的是评价定性和定量VIDAS RBG作为快速检测抗风疹IgG抗体的实验室检测方法的有效性。采用定性和定量RBG与RUBAZYME(雅培实验室)和标准血凝抑制(R-HI试剂盒,SEIKEN)同时平行检测200份高雄vgh患者的抗风疹IgG抗体检测血样。, 1993)。将定性和定量VIDAS RBG和RUBAZYME法与标准R-HI试验进行比较。三种方法的灵敏度差异显著(定性VIDAS RBG的灵敏度为100%,定量VIDAS RBG的灵敏度为88.89%,RUBAZYME的灵敏度为97.67%)。然而,这三种方法的特异性都是相同的,100%。由此可见,定性VIDAS RBG将为风疹病毒血清特异性IgG抗体的测定提供一种良好、准确、可靠的方法。此外,在临床实验室中,VIDAS RBG是完全自动化和节省时间的程序(每批测试,VIDAS RBG需要25分钟,RUBAZYME需要2.5小时,R-HI需要4.5小时)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[Laboratory evaluation of automated enzyme linked fluorescent assay for detecting serum specific IgG antibodies against rubella virus].

The VIDAS rubella IgG(RBG) is a new, automated, enzyme-linkad fluorescent assay(ELFA) for detecting IgG antibodies to rubella virus in serum. The purpose of this study was to evaluate the usefulness of the qualitative and quantitative VIDAS RBG as laboratory tests in the rapid detecting anti-rubella IgG antibodies. Simultaneous parallel testing was performed by using the qualitative and quantitative RBG along with RUBAZYME(ABBOTT LABORATORIES) and the standard hemagglutination-inhibition(HI) test(R-HI kit, SEIKEN) on 200 blood samples submitted for anti-rubella IgG antibodies testing from patients at the VGH-Kaohsiung(Mar.-Sep., 1993). The qualitative and quantitative VIDAS RBG and RUBAZYME assay were compared to the standard R-HI test. Significant differences among the sensitivities of these three methods were found (100% sensitivity for the qualitative VIDAS RBG, 88.89% for the quantitative VIDAS RBG and 97.67% for the RUBAZYME). However, the specificities of these three methods were all the same, 100%. With these results we can conclude that the qualitative VIDAS RBG will provide a very good, precise and reliable method to determine serum specific IgG antibodies against rubella virus. Furthermore, the VIDAS RBG is fully automated and time-saving procedures (for every batch of test, it takes 25 minutes with VIDAS RBG, 2.5 hours with RUBAZYME and 4.5 hours with R-HI) in clinical laboratories.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信