血管内外周动脉瘤修复中自膨胀支架的变形。

M E Sitsen, G H Ho, J D Blankensteijn
{"title":"血管内外周动脉瘤修复中自膨胀支架的变形。","authors":"M E Sitsen,&nbsp;G H Ho,&nbsp;J D Blankensteijn","doi":"10.1583/1074-6218(1999)006<0288:DOSSCE>2.0.CO;2","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To demonstrate the deformation of self-expandable stents after endovascular repair of peripheral aneurysms.</p><p><strong>Methods and results: </strong>The Corvita Endoluminal Graft was used to treat a traumatic false aneurysm of the right subclavian artery and a common iliac artery aneurysm in 2 patients. In the subclavian case, the stent-graft showed a \"cigar-shaped\" deformation with hemodynamically significant stenoses at the proximal and distal ends at 3 months. In the second case, the same type of deformity was noted only 1 day after implantation. Two months later, the stent-graft occluded, necessitating surgical repair.</p><p><strong>Conclusions: </strong>Both cases demonstrate the possibility of stent deformation of self-expanding stent-grafts implanted at arterial sites not subject to external compression.</p>","PeriodicalId":79443,"journal":{"name":"Journal of endovascular surgery : the official journal of the International Society for Endovascular Surgery","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1999-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"23","resultStr":"{\"title\":\"Deformation of self-expanding stent-grafts complicating endovascular peripheral aneurysm repair.\",\"authors\":\"M E Sitsen,&nbsp;G H Ho,&nbsp;J D Blankensteijn\",\"doi\":\"10.1583/1074-6218(1999)006<0288:DOSSCE>2.0.CO;2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To demonstrate the deformation of self-expandable stents after endovascular repair of peripheral aneurysms.</p><p><strong>Methods and results: </strong>The Corvita Endoluminal Graft was used to treat a traumatic false aneurysm of the right subclavian artery and a common iliac artery aneurysm in 2 patients. In the subclavian case, the stent-graft showed a \\\"cigar-shaped\\\" deformation with hemodynamically significant stenoses at the proximal and distal ends at 3 months. In the second case, the same type of deformity was noted only 1 day after implantation. Two months later, the stent-graft occluded, necessitating surgical repair.</p><p><strong>Conclusions: </strong>Both cases demonstrate the possibility of stent deformation of self-expanding stent-grafts implanted at arterial sites not subject to external compression.</p>\",\"PeriodicalId\":79443,\"journal\":{\"name\":\"Journal of endovascular surgery : the official journal of the International Society for Endovascular Surgery\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"23\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of endovascular surgery : the official journal of the International Society for Endovascular Surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1583/1074-6218(1999)006<0288:DOSSCE>2.0.CO;2\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of endovascular surgery : the official journal of the International Society for Endovascular Surgery","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1583/1074-6218(1999)006<0288:DOSSCE>2.0.CO;2","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 23

摘要

目的:观察血管内修复周围动脉瘤后自膨胀支架的变形情况。方法与结果:采用Corvita腔内移植物治疗外伤性右锁骨下动脉假性动脉瘤和髂总动脉瘤2例。在锁骨下病例中,支架移植物在3个月时出现“雪茄形”变形,并在近端和远端出现血流动力学上明显的狭窄。在第二个病例中,同一类型的畸形在植入后仅1天就出现了。两个月后,支架闭塞,需要手术修复。结论:这两个病例都表明,在动脉部位植入的自膨胀支架移植物不受外部压迫时可能发生支架变形。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Deformation of self-expanding stent-grafts complicating endovascular peripheral aneurysm repair.

Purpose: To demonstrate the deformation of self-expandable stents after endovascular repair of peripheral aneurysms.

Methods and results: The Corvita Endoluminal Graft was used to treat a traumatic false aneurysm of the right subclavian artery and a common iliac artery aneurysm in 2 patients. In the subclavian case, the stent-graft showed a "cigar-shaped" deformation with hemodynamically significant stenoses at the proximal and distal ends at 3 months. In the second case, the same type of deformity was noted only 1 day after implantation. Two months later, the stent-graft occluded, necessitating surgical repair.

Conclusions: Both cases demonstrate the possibility of stent deformation of self-expanding stent-grafts implanted at arterial sites not subject to external compression.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信