基于pc的实时动态搏动QT-RR分析系统

Dael Govreen-Segal , Michal M. Radai , Yakov Sivan , Shimon Abboud
{"title":"基于pc的实时动态搏动QT-RR分析系统","authors":"Dael Govreen-Segal ,&nbsp;Michal M. Radai ,&nbsp;Yakov Sivan ,&nbsp;Shimon Abboud","doi":"10.1006/cbmr.1999.1514","DOIUrl":null,"url":null,"abstract":"<div><p>A real-time analysis (RTA) system, based on a personal computer with a digital signal processor card (DSP) was developed. The system extracts and saves the <em>QT</em> and <em>RR</em> intervals from an incoming ECG signal sampled at 1 kHz. The method of defining the <em>QT</em> and <em>RR</em> intervals is based on performing multiple cross-correlations that enables rejection of artifacts from the analysis. The relationship between the <em>RR</em> and the <em>QT</em> intervals is found using the following general formula <em>QT</em><sub><em>i</em></sub><em>cRR</em><sup><em>i</em></sup><sub><em>i</em>−1</sub>. Linear regression is performed on the logarithms of <em>QT</em> and <em>RR</em> measurements obtained to estimate a constant (<em>a</em> = log<em>c</em>) and a slope (<em>b</em>), reflecting the dynamic change of the <em>QT</em> intervals. Having these two values, the dynamic <em>QT</em> extrapolated to a heart period of 1 s (<em>QT</em>cd) was calculated. The system also performs spectral analysis of the intervals and dynamic <em>QT-RR</em> relation analysis. The system was evaluated on recordings from 10 infants aged 4 to 24 weeks. The <em>QT</em>/<em>RR</em> computerized measuring device used in the present study answers to the requirements for precise dynamic beat-to-beat <em>QT</em> measurement. Its sampling rate is high and can achieve a real millisecond-precision without the need of interpolation methods. The measurements are performed on-line, at the time of the actual recording. Results appear immediately and a measure of dynamic <em>QT</em> behavior can be easily obtained within minutes. The computerized system with the dynamic <em>QT-RR</em> measurements may provide a simple and accurate tool for testing drug treatment and effects of other interventions for cardiac disorders and arrhythmia risk.</p></div>","PeriodicalId":75733,"journal":{"name":"Computers and biomedical research, an international journal","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1999-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1006/cbmr.1999.1514","citationCount":"14","resultStr":"{\"title\":\"Real-Time PC-Based System for Dynamic Beat-to-Beat QT-RR Analysis\",\"authors\":\"Dael Govreen-Segal ,&nbsp;Michal M. Radai ,&nbsp;Yakov Sivan ,&nbsp;Shimon Abboud\",\"doi\":\"10.1006/cbmr.1999.1514\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>A real-time analysis (RTA) system, based on a personal computer with a digital signal processor card (DSP) was developed. The system extracts and saves the <em>QT</em> and <em>RR</em> intervals from an incoming ECG signal sampled at 1 kHz. The method of defining the <em>QT</em> and <em>RR</em> intervals is based on performing multiple cross-correlations that enables rejection of artifacts from the analysis. The relationship between the <em>RR</em> and the <em>QT</em> intervals is found using the following general formula <em>QT</em><sub><em>i</em></sub><em>cRR</em><sup><em>i</em></sup><sub><em>i</em>−1</sub>. Linear regression is performed on the logarithms of <em>QT</em> and <em>RR</em> measurements obtained to estimate a constant (<em>a</em> = log<em>c</em>) and a slope (<em>b</em>), reflecting the dynamic change of the <em>QT</em> intervals. Having these two values, the dynamic <em>QT</em> extrapolated to a heart period of 1 s (<em>QT</em>cd) was calculated. The system also performs spectral analysis of the intervals and dynamic <em>QT-RR</em> relation analysis. The system was evaluated on recordings from 10 infants aged 4 to 24 weeks. The <em>QT</em>/<em>RR</em> computerized measuring device used in the present study answers to the requirements for precise dynamic beat-to-beat <em>QT</em> measurement. Its sampling rate is high and can achieve a real millisecond-precision without the need of interpolation methods. The measurements are performed on-line, at the time of the actual recording. Results appear immediately and a measure of dynamic <em>QT</em> behavior can be easily obtained within minutes. The computerized system with the dynamic <em>QT-RR</em> measurements may provide a simple and accurate tool for testing drug treatment and effects of other interventions for cardiac disorders and arrhythmia risk.</p></div>\",\"PeriodicalId\":75733,\"journal\":{\"name\":\"Computers and biomedical research, an international journal\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1999-08-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1006/cbmr.1999.1514\",\"citationCount\":\"14\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Computers and biomedical research, an international journal\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0010480999915148\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Computers and biomedical research, an international journal","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0010480999915148","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 14

摘要

开发了一种基于数字信号处理卡(DSP)的个人计算机实时分析系统。该系统从1 kHz的输入心电信号中提取并保存QT和RR间隔。定义QT和RR区间的方法基于执行多个相互关联,从而能够从分析中剔除工件。RR和QT间期之间的关系可以用下面的通式QTicRRii−1求得。对获得的QT和RR测量值的对数进行线性回归,以估计常数(a = logc)和斜率(b),反映QT间隔的动态变化。有了这两个值,动态QT外推心脏周期为1秒(QTcd)计算。系统还进行了区间的频谱分析和动态QT-RR关系分析。对10名4至24周婴儿的记录进行了评估。本研究中使用的QT/RR计算机测量装置满足了精确动态心跳间QT测量的要求。它的采样率高,可以达到真正的毫秒级精度,而不需要插值方法。测量是在实际记录时在线进行的。结果立即出现,动态QT行为的测量可以很容易地在几分钟内获得。具有动态QT-RR测量的计算机化系统可以为检测药物治疗和其他干预措施对心脏疾病和心律失常风险的影响提供简单而准确的工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Real-Time PC-Based System for Dynamic Beat-to-Beat QT-RR Analysis

A real-time analysis (RTA) system, based on a personal computer with a digital signal processor card (DSP) was developed. The system extracts and saves the QT and RR intervals from an incoming ECG signal sampled at 1 kHz. The method of defining the QT and RR intervals is based on performing multiple cross-correlations that enables rejection of artifacts from the analysis. The relationship between the RR and the QT intervals is found using the following general formula QTicRRii−1. Linear regression is performed on the logarithms of QT and RR measurements obtained to estimate a constant (a = logc) and a slope (b), reflecting the dynamic change of the QT intervals. Having these two values, the dynamic QT extrapolated to a heart period of 1 s (QTcd) was calculated. The system also performs spectral analysis of the intervals and dynamic QT-RR relation analysis. The system was evaluated on recordings from 10 infants aged 4 to 24 weeks. The QT/RR computerized measuring device used in the present study answers to the requirements for precise dynamic beat-to-beat QT measurement. Its sampling rate is high and can achieve a real millisecond-precision without the need of interpolation methods. The measurements are performed on-line, at the time of the actual recording. Results appear immediately and a measure of dynamic QT behavior can be easily obtained within minutes. The computerized system with the dynamic QT-RR measurements may provide a simple and accurate tool for testing drug treatment and effects of other interventions for cardiac disorders and arrhythmia risk.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信