P D Wimberley, R W Burnett, A K Covington, A H Maas, O Müeller-Plathe, O Siggaard-Andersen, H F Weisberg, W G Zijlstra
{"title":"经皮po2和pco2测量指南。","authors":"P D Wimberley, R W Burnett, A K Covington, A H Maas, O Müeller-Plathe, O Siggaard-Andersen, H F Weisberg, W G Zijlstra","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>This document provides guidelines in the terminology, methodology, and in the interpretation of data obtained from the use of skin (transcutaneous) p O2 and p CO2 electrodes. The transcutaneous technique has found special application for newborn infants. The causes of analytical bias with respect to arterial blood gas values and imprecision obtained with transcutaneous p O2 and p CO2 electrodes are reviewed. Electrode temperatures above 44 degrees C should not be used routinely, and, at a measuring temperature of 44 degrees C, the measuring site should be changed at least every 4 h to avoid skin burning.</p>","PeriodicalId":80043,"journal":{"name":"Journal of the International Federation of Clinical Chemistry","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1990-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Guidelines for transcutaneous p O2 and p CO2 measurement.\",\"authors\":\"P D Wimberley, R W Burnett, A K Covington, A H Maas, O Müeller-Plathe, O Siggaard-Andersen, H F Weisberg, W G Zijlstra\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>This document provides guidelines in the terminology, methodology, and in the interpretation of data obtained from the use of skin (transcutaneous) p O2 and p CO2 electrodes. The transcutaneous technique has found special application for newborn infants. The causes of analytical bias with respect to arterial blood gas values and imprecision obtained with transcutaneous p O2 and p CO2 electrodes are reviewed. Electrode temperatures above 44 degrees C should not be used routinely, and, at a measuring temperature of 44 degrees C, the measuring site should be changed at least every 4 h to avoid skin burning.</p>\",\"PeriodicalId\":80043,\"journal\":{\"name\":\"Journal of the International Federation of Clinical Chemistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1990-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the International Federation of Clinical Chemistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the International Federation of Clinical Chemistry","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Guidelines for transcutaneous p O2 and p CO2 measurement.
This document provides guidelines in the terminology, methodology, and in the interpretation of data obtained from the use of skin (transcutaneous) p O2 and p CO2 electrodes. The transcutaneous technique has found special application for newborn infants. The causes of analytical bias with respect to arterial blood gas values and imprecision obtained with transcutaneous p O2 and p CO2 electrodes are reviewed. Electrode temperatures above 44 degrees C should not be used routinely, and, at a measuring temperature of 44 degrees C, the measuring site should be changed at least every 4 h to avoid skin burning.