{"title":"超声在评价胆囊碎石术中的价值。","authors":"S H Lee, F P McGrath, J Zhou, H J Burhenne","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>To assess the reliability of ultrasound in measuring a minimum stone fragment burden we implanted radiolucent human gallstone fragments measuring from less than 1 mm up to 4 mm in size into the gallbladders of 12 domestic piglets. Forty-eight hours later the fragments in each animal were assessed by a qualified radiologist using two different ultrasound machines in a randomized blinded fashion. With regard to size estimation using a 5 MHz sector scanner, in two out of 12 examinations there was an overestimation of fragment size such that in a clinical setting an unneccessary repeat lithotripsy session would have been requested. A 5 MHz linear array transducer was of sufficient reliability in all size estimations not to have resulted in such a request. No gallbladder was falsely declared fragment free. There were nonshadowing fragments present in five of 12 examinations using both transducers. Clumping of small fragments less than or equal to 3 mm was present in two examinations. We recommend that a second ultrasound examination is performed when the presence of clumping is suspected and also when a fragment-free gallbladder is initially diagnosed.</p>","PeriodicalId":80212,"journal":{"name":"The Journal of lithotripsy & stone disease","volume":"3 4","pages":"319-23"},"PeriodicalIF":0.0000,"publicationDate":"1991-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"The value of sonography in the assessment of cholecystolithotripsy.\",\"authors\":\"S H Lee, F P McGrath, J Zhou, H J Burhenne\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>To assess the reliability of ultrasound in measuring a minimum stone fragment burden we implanted radiolucent human gallstone fragments measuring from less than 1 mm up to 4 mm in size into the gallbladders of 12 domestic piglets. Forty-eight hours later the fragments in each animal were assessed by a qualified radiologist using two different ultrasound machines in a randomized blinded fashion. With regard to size estimation using a 5 MHz sector scanner, in two out of 12 examinations there was an overestimation of fragment size such that in a clinical setting an unneccessary repeat lithotripsy session would have been requested. A 5 MHz linear array transducer was of sufficient reliability in all size estimations not to have resulted in such a request. No gallbladder was falsely declared fragment free. There were nonshadowing fragments present in five of 12 examinations using both transducers. Clumping of small fragments less than or equal to 3 mm was present in two examinations. We recommend that a second ultrasound examination is performed when the presence of clumping is suspected and also when a fragment-free gallbladder is initially diagnosed.</p>\",\"PeriodicalId\":80212,\"journal\":{\"name\":\"The Journal of lithotripsy & stone disease\",\"volume\":\"3 4\",\"pages\":\"319-23\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1991-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The Journal of lithotripsy & stone disease\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The Journal of lithotripsy & stone disease","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The value of sonography in the assessment of cholecystolithotripsy.
To assess the reliability of ultrasound in measuring a minimum stone fragment burden we implanted radiolucent human gallstone fragments measuring from less than 1 mm up to 4 mm in size into the gallbladders of 12 domestic piglets. Forty-eight hours later the fragments in each animal were assessed by a qualified radiologist using two different ultrasound machines in a randomized blinded fashion. With regard to size estimation using a 5 MHz sector scanner, in two out of 12 examinations there was an overestimation of fragment size such that in a clinical setting an unneccessary repeat lithotripsy session would have been requested. A 5 MHz linear array transducer was of sufficient reliability in all size estimations not to have resulted in such a request. No gallbladder was falsely declared fragment free. There were nonshadowing fragments present in five of 12 examinations using both transducers. Clumping of small fragments less than or equal to 3 mm was present in two examinations. We recommend that a second ultrasound examination is performed when the presence of clumping is suspected and also when a fragment-free gallbladder is initially diagnosed.