酶参考物质:在诊断酶学中的地位。

D W Moss
{"title":"酶参考物质:在诊断酶学中的地位。","authors":"D W Moss","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The method-dependency of measurements of enzyme activity presents problems of interpretation and comparison. Enzyme calibration materials may provide results in agreed-upon units of catalytic concentration while allowing a choice of routine methods. However, this requires the calibrating and calibrated methods to be equally specific, close agreement in intermethod ratio to exist between the calibrator and target enzyme in serum, and absence of significant sample-dependent variation in the intermethod ratio.</p>","PeriodicalId":80043,"journal":{"name":"Journal of the International Federation of Clinical Chemistry","volume":null,"pages":null},"PeriodicalIF":0.0000,"publicationDate":"1994-02-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Enzyme reference materials: their place in diagnostic enzymology.\",\"authors\":\"D W Moss\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The method-dependency of measurements of enzyme activity presents problems of interpretation and comparison. Enzyme calibration materials may provide results in agreed-upon units of catalytic concentration while allowing a choice of routine methods. However, this requires the calibrating and calibrated methods to be equally specific, close agreement in intermethod ratio to exist between the calibrator and target enzyme in serum, and absence of significant sample-dependent variation in the intermethod ratio.</p>\",\"PeriodicalId\":80043,\"journal\":{\"name\":\"Journal of the International Federation of Clinical Chemistry\",\"volume\":null,\"pages\":null},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1994-02-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the International Federation of Clinical Chemistry\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the International Federation of Clinical Chemistry","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

酶活性测量的方法依赖性提出了解释和比较的问题。酶校准材料可以提供催化浓度的商定单位的结果,同时允许选择常规方法。然而,这要求校准方法和被校准方法具有同等的特异性,校准器和血清中目标酶之间的方法间比率密切一致,并且在方法间比率中不存在显著的样品依赖性变化。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Enzyme reference materials: their place in diagnostic enzymology.

The method-dependency of measurements of enzyme activity presents problems of interpretation and comparison. Enzyme calibration materials may provide results in agreed-upon units of catalytic concentration while allowing a choice of routine methods. However, this requires the calibrating and calibrated methods to be equally specific, close agreement in intermethod ratio to exist between the calibrator and target enzyme in serum, and absence of significant sample-dependent variation in the intermethod ratio.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信