{"title":"确定萨里纪念医院餐饮服务人员的最佳工作台面高度。","authors":"J Stephenson","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>In anticipation of extensive kitchen renovations at Surrey Memorial Hospital, the median elbow height was determined for a group of 49 food service workers. From this measurement, an optimal range for work surface height of 824 mm to 874 mm was determined. This range is lower than that recommended by some ergonomics experts, and lower than the work surface height of much of the existing equipment in Patient Food Services. Work surface height should be considered when equipment is selected or modified as one possible measure to reduce the physical strain of food service work.</p>","PeriodicalId":79677,"journal":{"name":"Journal of the Canadian Dietetic Association","volume":"55 1","pages":"39-41"},"PeriodicalIF":0.0000,"publicationDate":"1994-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Determining optimal work surface height for Surrey Memorial Hospital food service workers.\",\"authors\":\"J Stephenson\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In anticipation of extensive kitchen renovations at Surrey Memorial Hospital, the median elbow height was determined for a group of 49 food service workers. From this measurement, an optimal range for work surface height of 824 mm to 874 mm was determined. This range is lower than that recommended by some ergonomics experts, and lower than the work surface height of much of the existing equipment in Patient Food Services. Work surface height should be considered when equipment is selected or modified as one possible measure to reduce the physical strain of food service work.</p>\",\"PeriodicalId\":79677,\"journal\":{\"name\":\"Journal of the Canadian Dietetic Association\",\"volume\":\"55 1\",\"pages\":\"39-41\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1994-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the Canadian Dietetic Association\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Canadian Dietetic Association","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
摘要
考虑到萨里纪念医院(Surrey Memorial Hospital)将对厨房进行大规模翻修,研究人员为49名餐饮服务人员确定了肘部的中位高度。通过测量,确定了工作表面高度的最佳范围为824 mm至874 mm。这个范围低于一些人体工程学专家建议的高度,也低于病人食品服务部门现有设备的工作台面高度。在选择或修改设备时,应考虑工作台面高度,作为减少食品服务工作的身体压力的一种可能措施。
Determining optimal work surface height for Surrey Memorial Hospital food service workers.
In anticipation of extensive kitchen renovations at Surrey Memorial Hospital, the median elbow height was determined for a group of 49 food service workers. From this measurement, an optimal range for work surface height of 824 mm to 874 mm was determined. This range is lower than that recommended by some ergonomics experts, and lower than the work surface height of much of the existing equipment in Patient Food Services. Work surface height should be considered when equipment is selected or modified as one possible measure to reduce the physical strain of food service work.