血管内超声导管血流评估:同时评估冠状动脉血流动力学和血管壁的理想工具?

S G Carlier, E I Cespedes, W Li, F Mastik, A F Van Der Steen, N Bom, P W Serruys
{"title":"血管内超声导管血流评估:同时评估冠状动脉血流动力学和血管壁的理想工具?","authors":"S G Carlier,&nbsp;E I Cespedes,&nbsp;W Li,&nbsp;F Mastik,&nbsp;A F Van Der Steen,&nbsp;N Bom,&nbsp;P W Serruys","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>We present the potentials of a novel method of intracoronary flow visualization and quantification that is based on conventional intravascular ultrasound (IVUS) imaging catheters. The quantification of flow is obtained from analysis of the rate of decorrelation of digitized radiofrequency ultrasound echo signals. Flow information is superimposed on the IVUS image using a colour scale. Integration of the blood velocity components normal to the scan plane permits calculation of the volume flow. Validation using IVUS and electromagnetic (EM) flowmeter recordings were obtained in vivo from instrumented pigs. IVUS flow (IVUS(f)) compared favourably to EM flow (EM(f)): IVUS(f)=1.0 EM(f)+5.72 cc/min, r2=0.98. Clinical results for the first five patients investigated are reported. A Doppler wire was used to measure the flow in four coronary arteries and one renal artery in baseline and hyperaemia conditions. IVUS flow and derived coronary flow reserve (CFR) demonstrated a very good agreement with the data derived from the combination of quantitative angiography and velocity when measured with the Doppler wire (DOP(f)): IVUS(f)=1.01 DOP(f)-20 cc/min, r2=0.90 and IVUS(cfr)=1.03 DOP(cfr)-0.03, r2=0.93. This demonstrates that simultaneous morphological and physiological assessment of coronary or peripheral arteries with one IVUS catheter is feasible. This method should be very useful for the evaluation of intermediate coronary stenoses or the results of revascularization procedures.</p>","PeriodicalId":79534,"journal":{"name":"Seminars in interventional cardiology : SIIC","volume":"3 1","pages":"21-9"},"PeriodicalIF":0.0000,"publicationDate":"1998-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Blood flow assessment with intravascular ultrasound catheters: the ideal tool for simultaneous assessment of the coronary haemodynamics and vessel wall?\",\"authors\":\"S G Carlier,&nbsp;E I Cespedes,&nbsp;W Li,&nbsp;F Mastik,&nbsp;A F Van Der Steen,&nbsp;N Bom,&nbsp;P W Serruys\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>We present the potentials of a novel method of intracoronary flow visualization and quantification that is based on conventional intravascular ultrasound (IVUS) imaging catheters. The quantification of flow is obtained from analysis of the rate of decorrelation of digitized radiofrequency ultrasound echo signals. Flow information is superimposed on the IVUS image using a colour scale. Integration of the blood velocity components normal to the scan plane permits calculation of the volume flow. Validation using IVUS and electromagnetic (EM) flowmeter recordings were obtained in vivo from instrumented pigs. IVUS flow (IVUS(f)) compared favourably to EM flow (EM(f)): IVUS(f)=1.0 EM(f)+5.72 cc/min, r2=0.98. Clinical results for the first five patients investigated are reported. A Doppler wire was used to measure the flow in four coronary arteries and one renal artery in baseline and hyperaemia conditions. IVUS flow and derived coronary flow reserve (CFR) demonstrated a very good agreement with the data derived from the combination of quantitative angiography and velocity when measured with the Doppler wire (DOP(f)): IVUS(f)=1.01 DOP(f)-20 cc/min, r2=0.90 and IVUS(cfr)=1.03 DOP(cfr)-0.03, r2=0.93. This demonstrates that simultaneous morphological and physiological assessment of coronary or peripheral arteries with one IVUS catheter is feasible. This method should be very useful for the evaluation of intermediate coronary stenoses or the results of revascularization procedures.</p>\",\"PeriodicalId\":79534,\"journal\":{\"name\":\"Seminars in interventional cardiology : SIIC\",\"volume\":\"3 1\",\"pages\":\"21-9\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1998-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Seminars in interventional cardiology : SIIC\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Seminars in interventional cardiology : SIIC","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

我们提出了一种基于传统血管内超声(IVUS)成像导管的冠状动脉内血流可视化和量化新方法的潜力。通过对数字化射频超声回波信号去相关率的分析,得到了流量的量化。流量信息是用彩色刻度叠加在IVUS图像上的。对垂直于扫描平面的血流速度分量的积分允许计算体积流量。利用IVUS和电磁(EM)流量计记录在仪器猪体内进行验证。IVUS流量(IVUS(f))优于EM流量(EM(f)): IVUS(f)=1.0 EM(f)+5.72 cc/min, r2=0.98。报告了前5例患者的临床结果。在基线和充血条件下,用多普勒线测量四条冠状动脉和一条肾动脉的血流。IVUS血流和衍生冠状动脉血流储备(CFR)与多普勒线(DOP(f))测量的定量血管造影和速度相结合的数据(DOP(f))非常吻合:IVUS(f)=1.01 DOP(f)-20 cc/min, r2=0.90; IVUS(CFR) =1.03 DOP(CFR) -0.03, r2=0.93。这表明用一根IVUS导管同时对冠状动脉或外周动脉进行形态和生理评估是可行的。这种方法对于评估中度冠状动脉狭窄或血管重建术的结果非常有用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Blood flow assessment with intravascular ultrasound catheters: the ideal tool for simultaneous assessment of the coronary haemodynamics and vessel wall?

We present the potentials of a novel method of intracoronary flow visualization and quantification that is based on conventional intravascular ultrasound (IVUS) imaging catheters. The quantification of flow is obtained from analysis of the rate of decorrelation of digitized radiofrequency ultrasound echo signals. Flow information is superimposed on the IVUS image using a colour scale. Integration of the blood velocity components normal to the scan plane permits calculation of the volume flow. Validation using IVUS and electromagnetic (EM) flowmeter recordings were obtained in vivo from instrumented pigs. IVUS flow (IVUS(f)) compared favourably to EM flow (EM(f)): IVUS(f)=1.0 EM(f)+5.72 cc/min, r2=0.98. Clinical results for the first five patients investigated are reported. A Doppler wire was used to measure the flow in four coronary arteries and one renal artery in baseline and hyperaemia conditions. IVUS flow and derived coronary flow reserve (CFR) demonstrated a very good agreement with the data derived from the combination of quantitative angiography and velocity when measured with the Doppler wire (DOP(f)): IVUS(f)=1.01 DOP(f)-20 cc/min, r2=0.90 and IVUS(cfr)=1.03 DOP(cfr)-0.03, r2=0.93. This demonstrates that simultaneous morphological and physiological assessment of coronary or peripheral arteries with one IVUS catheter is feasible. This method should be very useful for the evaluation of intermediate coronary stenoses or the results of revascularization procedures.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信