{"title":"40赫兹调制响应:预测正常听力成人低频不舒服的响度水平。","authors":"D Parker, D O'Dwyer","doi":"10.3109/00206099809072990","DOIUrl":null,"url":null,"abstract":"<p><p>Preliminary investigations have been made in normally hearing alert adults to establish whether the 40 Hz modulation-following response (MFR) can be used to predict 400 Hz uncomfortable loudness levels (ULLs). The MFR stimulus was a 400 Hz carrier, amplitude- and frequency-modulated by a 40 Hz sine function. Subjective ULLs were obtained using standard procedures. Objective ULLs were obtained from MFR parameter intensity functions using rms amplitude, phase angle and magnitude-squared coherence (40 Hz components). The best predictions of the subjective ULL were made using objective ULLs calculated from the gradients of linear best-fit lines for individual phase-intensity functions (80 per cent predicted within 10 dB of the subjective ULL; maximum deviation=16 dB). Poorest predictions were based on inter-subject average rms amplitude-intensity functions, where as few as 14 per cent were within 10 dB of the subjective value. The best predictions were considered sufficiently accurate to warrant further investigation using a variety of modulation and carrier frequencies in different age groups and with varying degrees of hearing loss.</p>","PeriodicalId":75571,"journal":{"name":"Audiology : official organ of the International Society of Audiology","volume":"37 6","pages":"372-81"},"PeriodicalIF":0.0000,"publicationDate":"1998-11-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/00206099809072990","citationCount":"7","resultStr":"{\"title\":\"The 40 Hz modulation-following response: prediction of low-frequency uncomfortable loudness levels in normally hearing adults.\",\"authors\":\"D Parker, D O'Dwyer\",\"doi\":\"10.3109/00206099809072990\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Preliminary investigations have been made in normally hearing alert adults to establish whether the 40 Hz modulation-following response (MFR) can be used to predict 400 Hz uncomfortable loudness levels (ULLs). The MFR stimulus was a 400 Hz carrier, amplitude- and frequency-modulated by a 40 Hz sine function. Subjective ULLs were obtained using standard procedures. Objective ULLs were obtained from MFR parameter intensity functions using rms amplitude, phase angle and magnitude-squared coherence (40 Hz components). The best predictions of the subjective ULL were made using objective ULLs calculated from the gradients of linear best-fit lines for individual phase-intensity functions (80 per cent predicted within 10 dB of the subjective ULL; maximum deviation=16 dB). Poorest predictions were based on inter-subject average rms amplitude-intensity functions, where as few as 14 per cent were within 10 dB of the subjective value. The best predictions were considered sufficiently accurate to warrant further investigation using a variety of modulation and carrier frequencies in different age groups and with varying degrees of hearing loss.</p>\",\"PeriodicalId\":75571,\"journal\":{\"name\":\"Audiology : official organ of the International Society of Audiology\",\"volume\":\"37 6\",\"pages\":\"372-81\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1998-11-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.3109/00206099809072990\",\"citationCount\":\"7\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Audiology : official organ of the International Society of Audiology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3109/00206099809072990\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Audiology : official organ of the International Society of Audiology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/00206099809072990","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
The 40 Hz modulation-following response: prediction of low-frequency uncomfortable loudness levels in normally hearing adults.
Preliminary investigations have been made in normally hearing alert adults to establish whether the 40 Hz modulation-following response (MFR) can be used to predict 400 Hz uncomfortable loudness levels (ULLs). The MFR stimulus was a 400 Hz carrier, amplitude- and frequency-modulated by a 40 Hz sine function. Subjective ULLs were obtained using standard procedures. Objective ULLs were obtained from MFR parameter intensity functions using rms amplitude, phase angle and magnitude-squared coherence (40 Hz components). The best predictions of the subjective ULL were made using objective ULLs calculated from the gradients of linear best-fit lines for individual phase-intensity functions (80 per cent predicted within 10 dB of the subjective ULL; maximum deviation=16 dB). Poorest predictions were based on inter-subject average rms amplitude-intensity functions, where as few as 14 per cent were within 10 dB of the subjective value. The best predictions were considered sufficiently accurate to warrant further investigation using a variety of modulation and carrier frequencies in different age groups and with varying degrees of hearing loss.