全髋关节置换术中使用近端多孔涂层股骨植入物的无骨水泥翻修。

G W Brindley, R Adams
{"title":"全髋关节置换术中使用近端多孔涂层股骨植入物的无骨水泥翻修。","authors":"G W Brindley,&nbsp;R Adams","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Thirty patients had 32 cementless total hip arthroplasty revisions and were evaluated postoperatively for clinical function (Harris Hip Score) and radiographic evidence of implant stability. Of the 26 femoral components revised, 16 were revised with anatomic long-stem femoral prostheses, and 10 were revised with straight mid-stem-length components. All components were collared and had circumferential proximal fiber-mesh porous coating. Seven of 16 patients had radiographic subsidence after revision with long-stem components (2 to 30 mm); 6 of 10 patients had subsidence after revision with mid-stem femoral components (2 to 25 mm). Of the 13 patients with femoral subsidence, 8 had calcar reconstruction with allograft bone; of the 13 patients without radiographic subsidence, 8 did not require calcar reconstruction. One of 27 fiber-mesh, porous-coated acetabular components migrated (30 mm). No components have been removed or revised. Even with circumferential proximal porous coating, femoral implant stability remains unpredictable in total hip arthroplasty revision.</p>","PeriodicalId":79349,"journal":{"name":"Journal of the Southern Orthopaedic Association","volume":"7 4","pages":"246-50"},"PeriodicalIF":0.0000,"publicationDate":"1998-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Cementless revision of total hip arthroplasty using proximal porous-coated femoral implants.\",\"authors\":\"G W Brindley,&nbsp;R Adams\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Thirty patients had 32 cementless total hip arthroplasty revisions and were evaluated postoperatively for clinical function (Harris Hip Score) and radiographic evidence of implant stability. Of the 26 femoral components revised, 16 were revised with anatomic long-stem femoral prostheses, and 10 were revised with straight mid-stem-length components. All components were collared and had circumferential proximal fiber-mesh porous coating. Seven of 16 patients had radiographic subsidence after revision with long-stem components (2 to 30 mm); 6 of 10 patients had subsidence after revision with mid-stem femoral components (2 to 25 mm). Of the 13 patients with femoral subsidence, 8 had calcar reconstruction with allograft bone; of the 13 patients without radiographic subsidence, 8 did not require calcar reconstruction. One of 27 fiber-mesh, porous-coated acetabular components migrated (30 mm). No components have been removed or revised. Even with circumferential proximal porous coating, femoral implant stability remains unpredictable in total hip arthroplasty revision.</p>\",\"PeriodicalId\":79349,\"journal\":{\"name\":\"Journal of the Southern Orthopaedic Association\",\"volume\":\"7 4\",\"pages\":\"246-50\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1998-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of the Southern Orthopaedic Association\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of the Southern Orthopaedic Association","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

30例患者行32例无骨水泥全髋关节置换术翻修,并对术后临床功能(Harris髋关节评分)和植入物稳定性的影像学证据进行评估。在26个股骨假体中,16个采用解剖长柄股骨假体,10个采用直中柄假体。所有的组件都被圈起来,并有近周的纤维网状多孔涂层。16例患者中有7例在长柄假体(2 ~ 30 mm)翻修后出现影像学沉降;10例患者中有6例在股骨中干假体(2 ~ 25mm)翻修后出现沉陷。13例股骨塌陷患者中,8例行同种异体骨重建;在13例无影像学沉降的患者中,8例不需要骨重建。27个纤维网,多孔涂层的髋臼组件中的一个迁移(30毫米)。没有删除或修改组件。在全髋关节置换术翻修中,即使采用近端多孔涂层,股骨假体的稳定性仍然不可预测。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Cementless revision of total hip arthroplasty using proximal porous-coated femoral implants.

Thirty patients had 32 cementless total hip arthroplasty revisions and were evaluated postoperatively for clinical function (Harris Hip Score) and radiographic evidence of implant stability. Of the 26 femoral components revised, 16 were revised with anatomic long-stem femoral prostheses, and 10 were revised with straight mid-stem-length components. All components were collared and had circumferential proximal fiber-mesh porous coating. Seven of 16 patients had radiographic subsidence after revision with long-stem components (2 to 30 mm); 6 of 10 patients had subsidence after revision with mid-stem femoral components (2 to 25 mm). Of the 13 patients with femoral subsidence, 8 had calcar reconstruction with allograft bone; of the 13 patients without radiographic subsidence, 8 did not require calcar reconstruction. One of 27 fiber-mesh, porous-coated acetabular components migrated (30 mm). No components have been removed or revised. Even with circumferential proximal porous coating, femoral implant stability remains unpredictable in total hip arthroplasty revision.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信