{"title":"扫描力显微镜法测定人中期染色体体积。","authors":"W Fritzsche, E Henderson","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>The scanning force microscopy (SFM) yields the topography of the investigated surface. A procedure was developed which starts from this three-dimensional information to estimate the volume of a biological specimen. The volume of spread human metaphase chromosomes was determined in air and rehydrated in aqueous buffer. A difference of the determined volume of a air-dried metaphase chromosome set was found compared to values from electron microscopic investigations, and could be correlated with differences in the hydration state of the chromosomes. SFM-based relative volumes of air-dried chromosomes resembles literature data regarding volume range and distribution. Possible application of SFM-based relative volume measurements for chromosome classification purposes is discussed.</p>","PeriodicalId":21502,"journal":{"name":"Scanning microscopy","volume":"10 1","pages":"103-8; discussion 108-10"},"PeriodicalIF":0.0000,"publicationDate":"1996-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Volume determination of human metaphase chromosomes by scanning force microscopy.\",\"authors\":\"W Fritzsche, E Henderson\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>The scanning force microscopy (SFM) yields the topography of the investigated surface. A procedure was developed which starts from this three-dimensional information to estimate the volume of a biological specimen. The volume of spread human metaphase chromosomes was determined in air and rehydrated in aqueous buffer. A difference of the determined volume of a air-dried metaphase chromosome set was found compared to values from electron microscopic investigations, and could be correlated with differences in the hydration state of the chromosomes. SFM-based relative volumes of air-dried chromosomes resembles literature data regarding volume range and distribution. Possible application of SFM-based relative volume measurements for chromosome classification purposes is discussed.</p>\",\"PeriodicalId\":21502,\"journal\":{\"name\":\"Scanning microscopy\",\"volume\":\"10 1\",\"pages\":\"103-8; discussion 108-10\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1996-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Scanning microscopy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Scanning microscopy","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
Volume determination of human metaphase chromosomes by scanning force microscopy.
The scanning force microscopy (SFM) yields the topography of the investigated surface. A procedure was developed which starts from this three-dimensional information to estimate the volume of a biological specimen. The volume of spread human metaphase chromosomes was determined in air and rehydrated in aqueous buffer. A difference of the determined volume of a air-dried metaphase chromosome set was found compared to values from electron microscopic investigations, and could be correlated with differences in the hydration state of the chromosomes. SFM-based relative volumes of air-dried chromosomes resembles literature data regarding volume range and distribution. Possible application of SFM-based relative volume measurements for chromosome classification purposes is discussed.