隐形眼镜下兔角膜氧张力的测定。

H Ichijima, T Hayashi, S Mitsunaga, H Hamano
{"title":"隐形眼镜下兔角膜氧张力的测定。","authors":"H Ichijima,&nbsp;T Hayashi,&nbsp;S Mitsunaga,&nbsp;H Hamano","doi":"","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To determine oxygen tension (PO2) on rabbit corneas beneath rigid gas permeable (RGP), hydrogel, and silicone elastomer lenses under open- and closed-eye conditions and to demonstrate the relationship between PO2 and overnight corneal swelling response in the rabbit model.</p><p><strong>Methods: </strong>An improved PO2 monitoring system (PO-2080) with a platinum-micro-wire-electrode was used to measure PO2. An ultrasonic pachymeter (DGH-2000) was used to measure corneal thickness after overnight wear.</p><p><strong>Results: </strong>The relationship between PO2 and oxygen transmissibility (Dk/ L) of the contact lens was linear for Dk/L between 0 and 70 x 10(-9) (cm/ sec)(mLO2/mL x mmHg). For Dk/L greater than 70 x 10(-9), PO2 gradually reached a plateau at 120 mmHg for open-eye conditions and 20 mmHg for closed-eye conditions. PO2 was inversely related to the overnight corneal swelling, ranging from 5.1% swelling at PO2 113.5/17.5 mmHg (open/closed-eye) for a hyper Dk/L lens (125 x 10(-9)) to 15.1% swelling at PO2 10.4/5.1 mmHg for a low Dk/L lens (11.5 x 10(-9)).</p><p><strong>Conclusions: </strong>Polarographic determination of PO2 provides reliable information about the amount of oxygen available to the cornea under a lens for both open-eye and closed-eye conditions. The data demonstrate that it is not possible to achieve normal oxygen levels with contact lens wear, even when hyper Dk/L lenses are worn.</p>","PeriodicalId":22367,"journal":{"name":"The CLAO journal : official publication of the Contact Lens Association of Ophthalmologists, Inc","volume":"24 4","pages":"220-6"},"PeriodicalIF":0.0000,"publicationDate":"1998-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Determination of oxygen tension on rabbit corneas under contact lenses.\",\"authors\":\"H Ichijima,&nbsp;T Hayashi,&nbsp;S Mitsunaga,&nbsp;H Hamano\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Purpose: </strong>To determine oxygen tension (PO2) on rabbit corneas beneath rigid gas permeable (RGP), hydrogel, and silicone elastomer lenses under open- and closed-eye conditions and to demonstrate the relationship between PO2 and overnight corneal swelling response in the rabbit model.</p><p><strong>Methods: </strong>An improved PO2 monitoring system (PO-2080) with a platinum-micro-wire-electrode was used to measure PO2. An ultrasonic pachymeter (DGH-2000) was used to measure corneal thickness after overnight wear.</p><p><strong>Results: </strong>The relationship between PO2 and oxygen transmissibility (Dk/ L) of the contact lens was linear for Dk/L between 0 and 70 x 10(-9) (cm/ sec)(mLO2/mL x mmHg). For Dk/L greater than 70 x 10(-9), PO2 gradually reached a plateau at 120 mmHg for open-eye conditions and 20 mmHg for closed-eye conditions. PO2 was inversely related to the overnight corneal swelling, ranging from 5.1% swelling at PO2 113.5/17.5 mmHg (open/closed-eye) for a hyper Dk/L lens (125 x 10(-9)) to 15.1% swelling at PO2 10.4/5.1 mmHg for a low Dk/L lens (11.5 x 10(-9)).</p><p><strong>Conclusions: </strong>Polarographic determination of PO2 provides reliable information about the amount of oxygen available to the cornea under a lens for both open-eye and closed-eye conditions. The data demonstrate that it is not possible to achieve normal oxygen levels with contact lens wear, even when hyper Dk/L lenses are worn.</p>\",\"PeriodicalId\":22367,\"journal\":{\"name\":\"The CLAO journal : official publication of the Contact Lens Association of Ophthalmologists, Inc\",\"volume\":\"24 4\",\"pages\":\"220-6\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1998-10-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"The CLAO journal : official publication of the Contact Lens Association of Ophthalmologists, Inc\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"The CLAO journal : official publication of the Contact Lens Association of Ophthalmologists, Inc","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的:测定兔角膜氧张力(PO2)在开放和闭眼条件下在硬质透气性(RGP)、水凝胶和硅弹性体透镜下的变化,并在兔模型中证明PO2与夜间角膜肿胀反应的关系。方法:采用改进的PO2监测系统(PO-2080)和铂微丝电极测量PO2。超声厚度计(DGH-2000)测量过夜磨损后角膜厚度。结果:PO2与隐形眼镜的氧传递率(Dk/ L)呈线性关系,Dk/L在0 ~ 70 × 10(-9) (cm/ sec)(mLO2/mL × mmHg)之间。当Dk/L大于70 × 10(-9)时,PO2在睁眼和闭眼条件下逐渐达到平台值,分别为120mmhg和20mmhg。PO2与夜间角膜肿胀呈负相关,对于高Dk/L晶体(125 × 10(-9)), PO2 113.5/17.5 mmHg(睁眼/闭眼)时的肿胀为5.1%,对于低Dk/L晶体(11.5 × 10(-9)), PO2 10.4/5.1 mmHg时的肿胀为15.1%。结论:极谱法测定PO2提供了关于睁眼和闭眼条件下角膜晶状体下可用氧气量的可靠信息。数据表明,即使戴着超Dk/L隐形眼镜,也不可能达到正常的氧气水平。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Determination of oxygen tension on rabbit corneas under contact lenses.

Purpose: To determine oxygen tension (PO2) on rabbit corneas beneath rigid gas permeable (RGP), hydrogel, and silicone elastomer lenses under open- and closed-eye conditions and to demonstrate the relationship between PO2 and overnight corneal swelling response in the rabbit model.

Methods: An improved PO2 monitoring system (PO-2080) with a platinum-micro-wire-electrode was used to measure PO2. An ultrasonic pachymeter (DGH-2000) was used to measure corneal thickness after overnight wear.

Results: The relationship between PO2 and oxygen transmissibility (Dk/ L) of the contact lens was linear for Dk/L between 0 and 70 x 10(-9) (cm/ sec)(mLO2/mL x mmHg). For Dk/L greater than 70 x 10(-9), PO2 gradually reached a plateau at 120 mmHg for open-eye conditions and 20 mmHg for closed-eye conditions. PO2 was inversely related to the overnight corneal swelling, ranging from 5.1% swelling at PO2 113.5/17.5 mmHg (open/closed-eye) for a hyper Dk/L lens (125 x 10(-9)) to 15.1% swelling at PO2 10.4/5.1 mmHg for a low Dk/L lens (11.5 x 10(-9)).

Conclusions: Polarographic determination of PO2 provides reliable information about the amount of oxygen available to the cornea under a lens for both open-eye and closed-eye conditions. The data demonstrate that it is not possible to achieve normal oxygen levels with contact lens wear, even when hyper Dk/L lenses are worn.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信