对消防员和潜水员的压缩呼吸空气的一氧化碳和水蒸气污染。

C C Austin, D J Ecobichon, G Dussault, C Tirado
{"title":"对消防员和潜水员的压缩呼吸空气的一氧化碳和水蒸气污染。","authors":"C C Austin,&nbsp;D J Ecobichon,&nbsp;G Dussault,&nbsp;C Tirado","doi":"10.1080/00984109708984073","DOIUrl":null,"url":null,"abstract":"<p><p>Compressed breathing air, used in self-contained breathing apparatus (SCBA) by firefighters and other categories of workers as well as by recreational and commercial divers, is prepared with the aid of high-pressure compressors operating in the range of 5000 psig. There have been reports of unexplained deaths of SCUBA divers and anecdotal accounts of decreased time to exhaustion in firefighters using SCBAs. Compressed breathing air has been found to contain elevated levels of carbon monoxide (CO) and water vapor that are consistent with carboxyhemoglobin (COHb) poisoning and freezing of the user's regulator on the breathing apparatus. The Coburn-Forster-Kane equation (CFK equation) was used to estimate COHb levels at rest and at maximum exercise when exposed to different levels of CO in contaminated breathing air. The results demonstrated that, at maximum exercise, the COHb ranged from 6.0 to 17% with the use of 1 to 4 SCBA cylinders contaminated by 250 ppm CO. Standard operating procedures have been developed at the Montreal Fire Department to minimize the risk of compressed breathing air contamination. Results of the quality analysis/quality control program indicate that implementation of these procedures has improved the quality of the compressed breathing air. Recommendations are made for improvement of the air testing procedures mandated by the Canadian CAN3 180.1-M85 Standard on Compressed Breathing Air and Systems.</p>","PeriodicalId":17524,"journal":{"name":"Journal of toxicology and environmental health","volume":"52 5","pages":"403-23"},"PeriodicalIF":0.0000,"publicationDate":"1997-12-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1080/00984109708984073","citationCount":"13","resultStr":"{\"title\":\"Carbon monoxide and water vapor contamination of compressed breathing air for firefighters and divers.\",\"authors\":\"C C Austin,&nbsp;D J Ecobichon,&nbsp;G Dussault,&nbsp;C Tirado\",\"doi\":\"10.1080/00984109708984073\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Compressed breathing air, used in self-contained breathing apparatus (SCBA) by firefighters and other categories of workers as well as by recreational and commercial divers, is prepared with the aid of high-pressure compressors operating in the range of 5000 psig. There have been reports of unexplained deaths of SCUBA divers and anecdotal accounts of decreased time to exhaustion in firefighters using SCBAs. Compressed breathing air has been found to contain elevated levels of carbon monoxide (CO) and water vapor that are consistent with carboxyhemoglobin (COHb) poisoning and freezing of the user's regulator on the breathing apparatus. The Coburn-Forster-Kane equation (CFK equation) was used to estimate COHb levels at rest and at maximum exercise when exposed to different levels of CO in contaminated breathing air. The results demonstrated that, at maximum exercise, the COHb ranged from 6.0 to 17% with the use of 1 to 4 SCBA cylinders contaminated by 250 ppm CO. Standard operating procedures have been developed at the Montreal Fire Department to minimize the risk of compressed breathing air contamination. Results of the quality analysis/quality control program indicate that implementation of these procedures has improved the quality of the compressed breathing air. Recommendations are made for improvement of the air testing procedures mandated by the Canadian CAN3 180.1-M85 Standard on Compressed Breathing Air and Systems.</p>\",\"PeriodicalId\":17524,\"journal\":{\"name\":\"Journal of toxicology and environmental health\",\"volume\":\"52 5\",\"pages\":\"403-23\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1997-12-12\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1080/00984109708984073\",\"citationCount\":\"13\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of toxicology and environmental health\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1080/00984109708984073\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of toxicology and environmental health","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1080/00984109708984073","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 13

摘要

压缩呼吸空气,用于自给式呼吸器(SCBA)的消防员和其他类别的工人,以及娱乐和商业潜水员,是在5000 psig范围内的高压压缩机的帮助下制备的。有报道称,有不明原因的水肺潜水员死亡,也有轶事称,使用scba的消防员疲劳时间缩短。压缩呼吸空气已被发现含有一氧化碳(CO)和水蒸气的水平升高,这与碳氧血红蛋白(COHb)中毒和用户的呼吸器上的调节器冻结一致。使用coburn - foster - kane方程(CFK方程)来估计暴露于污染空气中不同水平的CO时休息和最大运动时的COHb水平。结果表明,在最大限度的运动中,使用1到4个含有250 ppm CO污染的SCBA气瓶,COHb在6.0到17%之间。蒙特利尔消防局制定了标准操作程序,以尽量减少压缩呼吸空气污染的风险。质量分析/质量控制程序的结果表明,这些程序的实施改善了压缩呼吸空气的质量。对加拿大CAN3 180.1-M85压缩呼吸空气和系统标准规定的空气测试程序的改进提出了建议。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Carbon monoxide and water vapor contamination of compressed breathing air for firefighters and divers.

Compressed breathing air, used in self-contained breathing apparatus (SCBA) by firefighters and other categories of workers as well as by recreational and commercial divers, is prepared with the aid of high-pressure compressors operating in the range of 5000 psig. There have been reports of unexplained deaths of SCUBA divers and anecdotal accounts of decreased time to exhaustion in firefighters using SCBAs. Compressed breathing air has been found to contain elevated levels of carbon monoxide (CO) and water vapor that are consistent with carboxyhemoglobin (COHb) poisoning and freezing of the user's regulator on the breathing apparatus. The Coburn-Forster-Kane equation (CFK equation) was used to estimate COHb levels at rest and at maximum exercise when exposed to different levels of CO in contaminated breathing air. The results demonstrated that, at maximum exercise, the COHb ranged from 6.0 to 17% with the use of 1 to 4 SCBA cylinders contaminated by 250 ppm CO. Standard operating procedures have been developed at the Montreal Fire Department to minimize the risk of compressed breathing air contamination. Results of the quality analysis/quality control program indicate that implementation of these procedures has improved the quality of the compressed breathing air. Recommendations are made for improvement of the air testing procedures mandated by the Canadian CAN3 180.1-M85 Standard on Compressed Breathing Air and Systems.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信