[动态髋螺钉与γ -钉成骨术在不稳定股骨粗隆截骨术中的稳定性比较评价]。

W Kaiser, J Burmester, H Hausmann, V Gulielmos, M Hätzel, H J Merker
{"title":"[动态髋螺钉与γ -钉成骨术在不稳定股骨粗隆截骨术中的稳定性比较评价]。","authors":"W Kaiser,&nbsp;J Burmester,&nbsp;H Hausmann,&nbsp;V Gulielmos,&nbsp;M Hätzel,&nbsp;H J Merker","doi":"10.1007/BF02465097","DOIUrl":null,"url":null,"abstract":"<p><p>In 24 human cadaver femora standardized instable pertrochanteric osteotomies were created. The right and left femur of each pair were alternately selected for osteosyntheses with the gamma nail and the dynamic hip screw. Afterwards an examination of stability was performed. Cyclical loads were increased in 500 N increments to the maximum loading capacity, while the deformation rate was continuously measured. Radiographs were taken to prove the results of loading. The mean deformation was much greater in the DHS group than for the gamma nail, the maximum load to failure was significantly lower. Femoral shaft fractures caused by the loading occurred five times as often in the gamma nail osteosyntheses than in the DHS.</p>","PeriodicalId":17985,"journal":{"name":"Langenbecks Archiv fur Chirurgie","volume":"382 2","pages":"100-6"},"PeriodicalIF":0.0000,"publicationDate":"1997-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/BF02465097","citationCount":"6","resultStr":"{\"title\":\"[Comparative stability evaluation of dynamic hip screw and gamma-nail osteosyntheses in unstable pertrochanteric femoral osteotomies].\",\"authors\":\"W Kaiser,&nbsp;J Burmester,&nbsp;H Hausmann,&nbsp;V Gulielmos,&nbsp;M Hätzel,&nbsp;H J Merker\",\"doi\":\"10.1007/BF02465097\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>In 24 human cadaver femora standardized instable pertrochanteric osteotomies were created. The right and left femur of each pair were alternately selected for osteosyntheses with the gamma nail and the dynamic hip screw. Afterwards an examination of stability was performed. Cyclical loads were increased in 500 N increments to the maximum loading capacity, while the deformation rate was continuously measured. Radiographs were taken to prove the results of loading. The mean deformation was much greater in the DHS group than for the gamma nail, the maximum load to failure was significantly lower. Femoral shaft fractures caused by the loading occurred five times as often in the gamma nail osteosyntheses than in the DHS.</p>\",\"PeriodicalId\":17985,\"journal\":{\"name\":\"Langenbecks Archiv fur Chirurgie\",\"volume\":\"382 2\",\"pages\":\"100-6\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1997-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1007/BF02465097\",\"citationCount\":\"6\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Langenbecks Archiv fur Chirurgie\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/BF02465097\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Langenbecks Archiv fur Chirurgie","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/BF02465097","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 6

摘要

在24具人体尸体上进行了标准化不稳定股骨粗隆截骨术。每对股骨的左右股骨交替选择gamma钉和动力髋螺钉进行骨融合术。随后进行了稳定性检查。循环加载以500n为增量增加至最大加载能力,同时连续测量变形率。拍摄了x光片来证明加载的结果。DHS组的平均变形比gamma钉大得多,最大破坏载荷明显低于gamma钉。由载荷引起的股骨干骨折在gamma钉骨融合术中的发生率是DHS的5倍。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
[Comparative stability evaluation of dynamic hip screw and gamma-nail osteosyntheses in unstable pertrochanteric femoral osteotomies].

In 24 human cadaver femora standardized instable pertrochanteric osteotomies were created. The right and left femur of each pair were alternately selected for osteosyntheses with the gamma nail and the dynamic hip screw. Afterwards an examination of stability was performed. Cyclical loads were increased in 500 N increments to the maximum loading capacity, while the deformation rate was continuously measured. Radiographs were taken to prove the results of loading. The mean deformation was much greater in the DHS group than for the gamma nail, the maximum load to failure was significantly lower. Femoral shaft fractures caused by the loading occurred five times as often in the gamma nail osteosyntheses than in the DHS.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信