一种新型反射脉搏血氧仪在分娩过程中胎儿监测的准确性和实用性。

A Izumi, H Minakami, I Sato
{"title":"一种新型反射脉搏血氧仪在分娩过程中胎儿监测的准确性和实用性。","authors":"A Izumi,&nbsp;H Minakami,&nbsp;I Sato","doi":"10.1023/a:1007370920986","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To evaluate the accuracy of a new pulse oximeter in estimating the oxyhemoglobin (O2Hb) concentration in fetal arterial blood (SaO2) with either a high concentration of hemoglobin F (HbF) or a low concentration of O2Hb during labor.</p><p><strong>Patients and methods: </strong>Fetal forehead arterial oxygenation was determined in 44 fetuses by reflectance pulse oximeter (SpO2) during labor and was compared with SaO2 determined immediately after birth. Because HbF has little or no known effect on pulse oximetry, but does affect the laboratory multiwavelength \"CO-oximeter\" type reading, the SaO2 was corrected by HbF concentration. SpO2 and SaO2 were simultaneously measured in five hypoxic adult volunteers achieved by inhaling 11% oxygen.</p><p><strong>Results: </strong>A gradual decline in HbF concentration was seen during weeks 37 to 40 of gestation. HbF concentration varied near term, ranging between 53 and 88% of the fetal hemoglobin concentration (mean +/- SD = 74.6 +/- 6.3%). This alteration produced a lower %O2Hb percent by 4% at the most. The corrected SaO2 in cord blood correlated with fetal SpO2 (y = 0.974, x -7.279, r = 0.90). In five adults, SpO2 reflected well SaO2 with a mean +/- SD of bias of -1.1 +/- 2.9%.</p><p><strong>Conclusions: </strong>SpO2 determined by a new reflectance pulse oximeter at the end of labor correlated with an immediate post-natal cord arterial blood sample before the first breath, with a mean and SD of bias of 8.5 +/- 6.2%. Reflectance pulse oximetry is a useful tool for continuous noninvasive monitoring of the fetal oxygen status during labor.</p>","PeriodicalId":77199,"journal":{"name":"Journal of clinical monitoring","volume":"13 2","pages":"103-8"},"PeriodicalIF":0.0000,"publicationDate":"1997-03-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1023/a:1007370920986","citationCount":"2","resultStr":"{\"title\":\"Accuracy and utility of a new reflectance pulse oximeter for fetal monitoring during labor.\",\"authors\":\"A Izumi,&nbsp;H Minakami,&nbsp;I Sato\",\"doi\":\"10.1023/a:1007370920986\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><strong>Objective: </strong>To evaluate the accuracy of a new pulse oximeter in estimating the oxyhemoglobin (O2Hb) concentration in fetal arterial blood (SaO2) with either a high concentration of hemoglobin F (HbF) or a low concentration of O2Hb during labor.</p><p><strong>Patients and methods: </strong>Fetal forehead arterial oxygenation was determined in 44 fetuses by reflectance pulse oximeter (SpO2) during labor and was compared with SaO2 determined immediately after birth. Because HbF has little or no known effect on pulse oximetry, but does affect the laboratory multiwavelength \\\"CO-oximeter\\\" type reading, the SaO2 was corrected by HbF concentration. SpO2 and SaO2 were simultaneously measured in five hypoxic adult volunteers achieved by inhaling 11% oxygen.</p><p><strong>Results: </strong>A gradual decline in HbF concentration was seen during weeks 37 to 40 of gestation. HbF concentration varied near term, ranging between 53 and 88% of the fetal hemoglobin concentration (mean +/- SD = 74.6 +/- 6.3%). This alteration produced a lower %O2Hb percent by 4% at the most. The corrected SaO2 in cord blood correlated with fetal SpO2 (y = 0.974, x -7.279, r = 0.90). In five adults, SpO2 reflected well SaO2 with a mean +/- SD of bias of -1.1 +/- 2.9%.</p><p><strong>Conclusions: </strong>SpO2 determined by a new reflectance pulse oximeter at the end of labor correlated with an immediate post-natal cord arterial blood sample before the first breath, with a mean and SD of bias of 8.5 +/- 6.2%. Reflectance pulse oximetry is a useful tool for continuous noninvasive monitoring of the fetal oxygen status during labor.</p>\",\"PeriodicalId\":77199,\"journal\":{\"name\":\"Journal of clinical monitoring\",\"volume\":\"13 2\",\"pages\":\"103-8\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1997-03-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1023/a:1007370920986\",\"citationCount\":\"2\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of clinical monitoring\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1023/a:1007370920986\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of clinical monitoring","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1023/a:1007370920986","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 2

摘要

目的:评价一种新型脉搏血氧仪在分娩时血红蛋白F (HbF)浓度高或O2Hb浓度低的胎儿动脉血(SaO2)中氧合血红蛋白(O2Hb)浓度测定的准确性。患者与方法:采用反射式脉搏血氧仪(SpO2)测定44例胎儿产程中胎儿前额动脉氧合水平,并与出生后立即测定的胎儿前额动脉氧合水平进行比较。由于HbF对脉搏血氧测量的影响很小或没有已知的影响,但确实影响实验室多波长“co -血氧计”类型的读数,因此用HbF浓度校正SaO2。同时测定5名低氧成人志愿者的SpO2和SaO2。结果:HbF浓度在妊娠37 ~ 40周逐渐下降。近期HbF浓度变化,范围在胎儿血红蛋白浓度的53 - 88%之间(平均+/- SD = 74.6 +/- 6.3%)。这种改变最多产生4%的较低的%O2Hb %。校正后脐带血SaO2与胎儿SpO2呈正相关(y = 0.974, x -7.279, r = 0.90)。在5名成年人中,SpO2很好地反映了SaO2,平均+/- SD偏差为-1.1 +/- 2.9%。结论:新型反射式脉搏血氧仪在分娩结束时测得的血氧饱和度与产后第一次呼吸前立即采集脐带动脉血样本相关,其平均值和偏差标准差为8.5±6.2%。反射脉搏血氧仪是一种有用的工具,用于连续无创监测胎儿在分娩过程中的氧气状况。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Accuracy and utility of a new reflectance pulse oximeter for fetal monitoring during labor.

Objective: To evaluate the accuracy of a new pulse oximeter in estimating the oxyhemoglobin (O2Hb) concentration in fetal arterial blood (SaO2) with either a high concentration of hemoglobin F (HbF) or a low concentration of O2Hb during labor.

Patients and methods: Fetal forehead arterial oxygenation was determined in 44 fetuses by reflectance pulse oximeter (SpO2) during labor and was compared with SaO2 determined immediately after birth. Because HbF has little or no known effect on pulse oximetry, but does affect the laboratory multiwavelength "CO-oximeter" type reading, the SaO2 was corrected by HbF concentration. SpO2 and SaO2 were simultaneously measured in five hypoxic adult volunteers achieved by inhaling 11% oxygen.

Results: A gradual decline in HbF concentration was seen during weeks 37 to 40 of gestation. HbF concentration varied near term, ranging between 53 and 88% of the fetal hemoglobin concentration (mean +/- SD = 74.6 +/- 6.3%). This alteration produced a lower %O2Hb percent by 4% at the most. The corrected SaO2 in cord blood correlated with fetal SpO2 (y = 0.974, x -7.279, r = 0.90). In five adults, SpO2 reflected well SaO2 with a mean +/- SD of bias of -1.1 +/- 2.9%.

Conclusions: SpO2 determined by a new reflectance pulse oximeter at the end of labor correlated with an immediate post-natal cord arterial blood sample before the first breath, with a mean and SD of bias of 8.5 +/- 6.2%. Reflectance pulse oximetry is a useful tool for continuous noninvasive monitoring of the fetal oxygen status during labor.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信