A Kitajima, K Yoshii, H Komatsu, S Ishimitsu, S Okada
{"title":"[国家卫生科学研究所抗坏血酸参考标准(Control 931)]。","authors":"A Kitajima, K Yoshii, H Komatsu, S Ishimitsu, S Okada","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Raw ascorbic acid material was tested for preparation of the \"Ascorbic Acid Reference Standard (Control 931)\". Analytical data obtained were as follows: infrared spectrum, the same as that of the JP Ascorbic Acid Reference Standard; optical rotation -alpha-20D, + 21.4 degrees; melting point, 190.3 degrees C (decomposition); loss on drying, 0.02%; assay result, 100.1% by iodometry. Based on the above findings, the raw material was authorized as the JP Ascorbic Acid Reference Standard (Control 931).</p>","PeriodicalId":11656,"journal":{"name":"Eisei Shikenjo hokoku. Bulletin of National Institute of Hygienic Sciences","volume":" 112","pages":"183-4"},"PeriodicalIF":0.0000,"publicationDate":"1994-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[The Ascorbic Acid Reference Standard (Control 931) of the National Institute of Health Sciences].\",\"authors\":\"A Kitajima, K Yoshii, H Komatsu, S Ishimitsu, S Okada\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Raw ascorbic acid material was tested for preparation of the \\\"Ascorbic Acid Reference Standard (Control 931)\\\". Analytical data obtained were as follows: infrared spectrum, the same as that of the JP Ascorbic Acid Reference Standard; optical rotation -alpha-20D, + 21.4 degrees; melting point, 190.3 degrees C (decomposition); loss on drying, 0.02%; assay result, 100.1% by iodometry. Based on the above findings, the raw material was authorized as the JP Ascorbic Acid Reference Standard (Control 931).</p>\",\"PeriodicalId\":11656,\"journal\":{\"name\":\"Eisei Shikenjo hokoku. Bulletin of National Institute of Hygienic Sciences\",\"volume\":\" 112\",\"pages\":\"183-4\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1994-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Eisei Shikenjo hokoku. Bulletin of National Institute of Hygienic Sciences\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eisei Shikenjo hokoku. Bulletin of National Institute of Hygienic Sciences","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
[The Ascorbic Acid Reference Standard (Control 931) of the National Institute of Health Sciences].
Raw ascorbic acid material was tested for preparation of the "Ascorbic Acid Reference Standard (Control 931)". Analytical data obtained were as follows: infrared spectrum, the same as that of the JP Ascorbic Acid Reference Standard; optical rotation -alpha-20D, + 21.4 degrees; melting point, 190.3 degrees C (decomposition); loss on drying, 0.02%; assay result, 100.1% by iodometry. Based on the above findings, the raw material was authorized as the JP Ascorbic Acid Reference Standard (Control 931).