{"title":"两种尖端压力传感器系统的体内比较。","authors":"A E Aubert, M Vrolix, H De Geest, F Van de Werf","doi":"10.1007/BF01142487","DOIUrl":null,"url":null,"abstract":"<p><p>Experimental findings are presented of an in vivo comparison between a Sentron catheter and another tip transducer manometer: a Millar microtip catheter. Both catheters have been used simultaneously in the left ventricle of dogs. Pressure variations were elicited by drug infusion. Pressure values and derivatives obtained from both systems were compared. A cross correlation between episodes of the two pressures was computed. Results from this study showed good correlation between left ventricular systolic pressure measured with both manometers (R = 0.992, p < 0.0001), end-diastolic pressure (R = 0.809, p < 0.0001) and between first derivatives: positive derivative (R = 0.993, p < 0.0001) and negative (R = 0.634, p < 0.0001). The mean cross correlation between both pressure signals was 0.61 +/- 0.04. In the frequency domain no statistical difference was found between the location of the maxima of the peaks. It is concluded that a Sentron manometer can be a valid alternative, at a reasonable price, to a cheaper, though less accurate fluid filled catheter and a more expensive 'golden standard' microtip catheter.</p>","PeriodicalId":77181,"journal":{"name":"International journal of clinical monitoring and computing","volume":"12 2","pages":"77-83"},"PeriodicalIF":0.0000,"publicationDate":"1995-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1007/BF01142487","citationCount":"14","resultStr":"{\"title\":\"In vivo comparison between two tip pressure transducer systems.\",\"authors\":\"A E Aubert, M Vrolix, H De Geest, F Van de Werf\",\"doi\":\"10.1007/BF01142487\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Experimental findings are presented of an in vivo comparison between a Sentron catheter and another tip transducer manometer: a Millar microtip catheter. Both catheters have been used simultaneously in the left ventricle of dogs. Pressure variations were elicited by drug infusion. Pressure values and derivatives obtained from both systems were compared. A cross correlation between episodes of the two pressures was computed. Results from this study showed good correlation between left ventricular systolic pressure measured with both manometers (R = 0.992, p < 0.0001), end-diastolic pressure (R = 0.809, p < 0.0001) and between first derivatives: positive derivative (R = 0.993, p < 0.0001) and negative (R = 0.634, p < 0.0001). The mean cross correlation between both pressure signals was 0.61 +/- 0.04. In the frequency domain no statistical difference was found between the location of the maxima of the peaks. It is concluded that a Sentron manometer can be a valid alternative, at a reasonable price, to a cheaper, though less accurate fluid filled catheter and a more expensive 'golden standard' microtip catheter.</p>\",\"PeriodicalId\":77181,\"journal\":{\"name\":\"International journal of clinical monitoring and computing\",\"volume\":\"12 2\",\"pages\":\"77-83\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1995-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1007/BF01142487\",\"citationCount\":\"14\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"International journal of clinical monitoring and computing\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.1007/BF01142487\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of clinical monitoring and computing","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1007/BF01142487","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 14
摘要
实验结果提出了Sentron导管和另一个尖端传感器压力计:米勒微尖端导管之间的体内比较。两种导管已同时用于狗的左心室。药物输注引起压力变化。比较了两种系统的压力值和导数。计算了两种压力发作之间的相互关系。本研究结果显示,两种压力计测量的左心室收缩压(R = 0.992, p < 0.0001)与舒张末期压(R = 0.809, p < 0.0001)以及一阶导数之间的相关性良好:正导数(R = 0.993, p < 0.0001)与负导数(R = 0.634, p < 0.0001)。两种压力信号的平均相关系数为0.61±0.04。在频域中,峰值的位置没有统计学差异。结论是,Sentron压力计可以以合理的价格替代更便宜,但精度较低的液体填充导管和更昂贵的“黄金标准”微尖导管。
In vivo comparison between two tip pressure transducer systems.
Experimental findings are presented of an in vivo comparison between a Sentron catheter and another tip transducer manometer: a Millar microtip catheter. Both catheters have been used simultaneously in the left ventricle of dogs. Pressure variations were elicited by drug infusion. Pressure values and derivatives obtained from both systems were compared. A cross correlation between episodes of the two pressures was computed. Results from this study showed good correlation between left ventricular systolic pressure measured with both manometers (R = 0.992, p < 0.0001), end-diastolic pressure (R = 0.809, p < 0.0001) and between first derivatives: positive derivative (R = 0.993, p < 0.0001) and negative (R = 0.634, p < 0.0001). The mean cross correlation between both pressure signals was 0.61 +/- 0.04. In the frequency domain no statistical difference was found between the location of the maxima of the peaks. It is concluded that a Sentron manometer can be a valid alternative, at a reasonable price, to a cheaper, though less accurate fluid filled catheter and a more expensive 'golden standard' microtip catheter.