注射吸毒者在清洗注射器时接触漂白剂的次数不足。

A A Gleghorn, M C Doherty, D Vlahov, D D Celentano, T S Jones
{"title":"注射吸毒者在清洗注射器时接触漂白剂的次数不足。","authors":"A A Gleghorn,&nbsp;M C Doherty,&nbsp;D Vlahov,&nbsp;D D Celentano,&nbsp;T S Jones","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Objectives were to measure syringe cleaning strategies used by injection drug users (IDUs) and to assess syringe contact with bleach during cleaning demonstrations. IDUs were interviewed about cleaning activities during their most recent injection episode; they demonstrated these activities on videotape. Coders reviewed the videotapes, categorized activities, and used stop watches to record bleach exposure. Of 161, 146 subjects reported cleaning at last injection, 85 (58%) of 146 used full strength bleach. Of bleach users, 20% had total contact time (duration of bleach inside syringe) of > or = 30 s; combining draw (time taken to fill syringe) and contact times, 54% of bleach users had total \"flush\" times of > or = 30 s. Median observed time per bleach flush was 16 s. Median reported cleaning times were twice as long as observed. Recent reports indicate 30 s of exposure to undiluted bleach is necessary to inactivate HIV in the laboratory; here, 80% of IDUs using bleach had contact of < 30 s. Judgment of contact time was inaccurate. On average, instructions advocating two bleach flushes may reach 30 s; here, half the subjects had insufficient time with two flushes. The majority showed inadequate techniques, therefore, alternate cleaning strategies should be developed.</p>","PeriodicalId":14827,"journal":{"name":"Journal of acquired immune deficiency syndromes","volume":"7 7","pages":"767-72"},"PeriodicalIF":0.0000,"publicationDate":"1994-07-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Inadequate bleach contact times during syringe cleaning among injection drug users.\",\"authors\":\"A A Gleghorn,&nbsp;M C Doherty,&nbsp;D Vlahov,&nbsp;D D Celentano,&nbsp;T S Jones\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Objectives were to measure syringe cleaning strategies used by injection drug users (IDUs) and to assess syringe contact with bleach during cleaning demonstrations. IDUs were interviewed about cleaning activities during their most recent injection episode; they demonstrated these activities on videotape. Coders reviewed the videotapes, categorized activities, and used stop watches to record bleach exposure. Of 161, 146 subjects reported cleaning at last injection, 85 (58%) of 146 used full strength bleach. Of bleach users, 20% had total contact time (duration of bleach inside syringe) of > or = 30 s; combining draw (time taken to fill syringe) and contact times, 54% of bleach users had total \\\"flush\\\" times of > or = 30 s. Median observed time per bleach flush was 16 s. Median reported cleaning times were twice as long as observed. Recent reports indicate 30 s of exposure to undiluted bleach is necessary to inactivate HIV in the laboratory; here, 80% of IDUs using bleach had contact of < 30 s. Judgment of contact time was inaccurate. On average, instructions advocating two bleach flushes may reach 30 s; here, half the subjects had insufficient time with two flushes. The majority showed inadequate techniques, therefore, alternate cleaning strategies should be developed.</p>\",\"PeriodicalId\":14827,\"journal\":{\"name\":\"Journal of acquired immune deficiency syndromes\",\"volume\":\"7 7\",\"pages\":\"767-72\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1994-07-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Journal of acquired immune deficiency syndromes\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of acquired immune deficiency syndromes","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

目的是测量注射吸毒者(IDUs)使用的注射器清洁策略,并评估在清洁演示过程中注射器与漂白剂的接触。对注射吸毒者进行了关于其最近一次注射期间清洁活动的访谈;他们用录像带展示了这些活动。编码员审查录像带,对活动进行分类,并用秒表记录漂白剂暴露的情况。在161名受试者中,146名受试者报告在最后注射时清洁,其中85名(58%)使用全强度漂白剂。在漂白剂使用者中,20%的总接触时间(漂白剂在注射器内的持续时间)>或= 30秒;结合抽吸(填充注射器所需的时间)和接触次数,54%的漂白剂使用者的总“冲洗”时间>或= 30秒。每次漂白剂冲洗的平均观察时间为16秒。报告的平均清洁时间是观察到的两倍。最近的报告表明,要在实验室灭活艾滋病毒,接触未稀释的漂白剂30秒是必要的;在这里,80%使用漂白剂的idu接触时间< 30 s。接触时间判断不准确。平均而言,建议两次漂白剂冲洗的说明可能达到30秒;在这里,一半的受试者没有足够的时间做两次脸红。大多数显示技术不足,因此,应制定替代清洁战略。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Inadequate bleach contact times during syringe cleaning among injection drug users.

Objectives were to measure syringe cleaning strategies used by injection drug users (IDUs) and to assess syringe contact with bleach during cleaning demonstrations. IDUs were interviewed about cleaning activities during their most recent injection episode; they demonstrated these activities on videotape. Coders reviewed the videotapes, categorized activities, and used stop watches to record bleach exposure. Of 161, 146 subjects reported cleaning at last injection, 85 (58%) of 146 used full strength bleach. Of bleach users, 20% had total contact time (duration of bleach inside syringe) of > or = 30 s; combining draw (time taken to fill syringe) and contact times, 54% of bleach users had total "flush" times of > or = 30 s. Median observed time per bleach flush was 16 s. Median reported cleaning times were twice as long as observed. Recent reports indicate 30 s of exposure to undiluted bleach is necessary to inactivate HIV in the laboratory; here, 80% of IDUs using bleach had contact of < 30 s. Judgment of contact time was inaccurate. On average, instructions advocating two bleach flushes may reach 30 s; here, half the subjects had insufficient time with two flushes. The majority showed inadequate techniques, therefore, alternate cleaning strategies should be developed.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信