{"title":"电热地毯对室内尘螨的影响。","authors":"M Shibasaki,&nbsp;H Takita","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>An electric heating carpet (EHC) that had been especially modified to produce a steady surface temperature of 45 to 50 degrees C was set up in the bedroom of an asthmatic patient, and the density of floor dust mites in this room was compared monthly for 2 years with that in two non-EHC control rooms. When the EHC was used during the mite-growing summer season, the monthly variation in mite density in the EHC room was almost parallel to that in the non-EHC rooms, with a preponderance of floor mites in the non-EHC rooms. In contrast, when the EHC was used during the winter season, the density of floor mites in the EHC room increased as compared with that in the non-EHC rooms, and the ratio of mite density in the EHC room to that in the non-EHC rooms was transiently reversed during this period.</p>","PeriodicalId":7931,"journal":{"name":"Annals of allergy","volume":"72 6","pages":"541-5"},"PeriodicalIF":0.0000,"publicationDate":"1994-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Effect of electric heating carpet on house dust mites.\",\"authors\":\"M Shibasaki,&nbsp;H Takita\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>An electric heating carpet (EHC) that had been especially modified to produce a steady surface temperature of 45 to 50 degrees C was set up in the bedroom of an asthmatic patient, and the density of floor dust mites in this room was compared monthly for 2 years with that in two non-EHC control rooms. When the EHC was used during the mite-growing summer season, the monthly variation in mite density in the EHC room was almost parallel to that in the non-EHC rooms, with a preponderance of floor mites in the non-EHC rooms. In contrast, when the EHC was used during the winter season, the density of floor mites in the EHC room increased as compared with that in the non-EHC rooms, and the ratio of mite density in the EHC room to that in the non-EHC rooms was transiently reversed during this period.</p>\",\"PeriodicalId\":7931,\"journal\":{\"name\":\"Annals of allergy\",\"volume\":\"72 6\",\"pages\":\"541-5\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1994-06-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Annals of allergy\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of allergy","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

在一名哮喘患者的卧室内放置经特殊改造使表面温度稳定在45 ~ 50℃的电热地毯(EHC),并将该房间的地板尘螨密度与两个非EHC控制室的地板尘螨密度进行2年的每月比较。在夏季螨类生长季节使用EHC时,EHC房间螨密度的月变化与非EHC房间几乎平行,非EHC房间的地板螨占优势。而在冬季使用EHC时,EHC房间的地板螨密度比非EHC房间的地板螨密度增加,并且在此期间EHC房间与非EHC房间的螨密度之比出现了短暂的反转。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effect of electric heating carpet on house dust mites.

An electric heating carpet (EHC) that had been especially modified to produce a steady surface temperature of 45 to 50 degrees C was set up in the bedroom of an asthmatic patient, and the density of floor dust mites in this room was compared monthly for 2 years with that in two non-EHC control rooms. When the EHC was used during the mite-growing summer season, the monthly variation in mite density in the EHC room was almost parallel to that in the non-EHC rooms, with a preponderance of floor mites in the non-EHC rooms. In contrast, when the EHC was used during the winter season, the density of floor mites in the EHC room increased as compared with that in the non-EHC rooms, and the ratio of mite density in the EHC room to that in the non-EHC rooms was transiently reversed during this period.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信