{"title":"超声检测羊水——两种方法的比较","authors":"C Wurl, J W Dudenhausen","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>A study was performed in order to find a suitable ultrasonographic method of determining amniotic fluid volumes. Volumes were measured in 398 gravidae with no fetal or maternal pathology. The Depot V method described by Chamberlain et al. and Phelan et al.'s four-quadrant method were used to perform the measurements. Normal-value curves were prepared from the results. The reproducibility of the two methods was also verified. The results of the study showed that the normal-value curve derived from the four-quadrant method was in very good agreement with the results of the quantitative indicator dilution methods described by Queenan et al., which also indicated a marked decrease in volume after GW 34. It may be concluded from this that the four-quadrant method produces representative figures for the actual volume of amniotic fluid. A further distinctive feature of the four-quadrant methods is its very good reproducibility. The decrease in the fluid volume towards the end of gestation could not be demonstrated by the Depot V method. The four-quadrant method may therefore be regarded as a suitable semi-quantitative ultrasonographic method of determining the amniotic fluid volume.</p>","PeriodicalId":23919,"journal":{"name":"Zeitschrift fur Geburtshilfe und Perinatologie","volume":"198 1","pages":"22-6"},"PeriodicalIF":0.0000,"publicationDate":"1994-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"[Ultrasonographic determination of amniotic fluid--comparison of two methods].\",\"authors\":\"C Wurl, J W Dudenhausen\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A study was performed in order to find a suitable ultrasonographic method of determining amniotic fluid volumes. Volumes were measured in 398 gravidae with no fetal or maternal pathology. The Depot V method described by Chamberlain et al. and Phelan et al.'s four-quadrant method were used to perform the measurements. Normal-value curves were prepared from the results. The reproducibility of the two methods was also verified. The results of the study showed that the normal-value curve derived from the four-quadrant method was in very good agreement with the results of the quantitative indicator dilution methods described by Queenan et al., which also indicated a marked decrease in volume after GW 34. It may be concluded from this that the four-quadrant method produces representative figures for the actual volume of amniotic fluid. A further distinctive feature of the four-quadrant methods is its very good reproducibility. The decrease in the fluid volume towards the end of gestation could not be demonstrated by the Depot V method. The four-quadrant method may therefore be regarded as a suitable semi-quantitative ultrasonographic method of determining the amniotic fluid volume.</p>\",\"PeriodicalId\":23919,\"journal\":{\"name\":\"Zeitschrift fur Geburtshilfe und Perinatologie\",\"volume\":\"198 1\",\"pages\":\"22-6\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1994-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Zeitschrift fur Geburtshilfe und Perinatologie\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Zeitschrift fur Geburtshilfe und Perinatologie","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
[Ultrasonographic determination of amniotic fluid--comparison of two methods].
A study was performed in order to find a suitable ultrasonographic method of determining amniotic fluid volumes. Volumes were measured in 398 gravidae with no fetal or maternal pathology. The Depot V method described by Chamberlain et al. and Phelan et al.'s four-quadrant method were used to perform the measurements. Normal-value curves were prepared from the results. The reproducibility of the two methods was also verified. The results of the study showed that the normal-value curve derived from the four-quadrant method was in very good agreement with the results of the quantitative indicator dilution methods described by Queenan et al., which also indicated a marked decrease in volume after GW 34. It may be concluded from this that the four-quadrant method produces representative figures for the actual volume of amniotic fluid. A further distinctive feature of the four-quadrant methods is its very good reproducibility. The decrease in the fluid volume towards the end of gestation could not be demonstrated by the Depot V method. The four-quadrant method may therefore be regarded as a suitable semi-quantitative ultrasonographic method of determining the amniotic fluid volume.