用近红外光谱客观评价间歇性跛行

Takashi Komiyama, Hiroshi Shigematsu, Hiroshi Yasuhara, Tetsuichiro Muto
{"title":"用近红外光谱客观评价间歇性跛行","authors":"Takashi Komiyama,&nbsp;Hiroshi Shigematsu,&nbsp;Hiroshi Yasuhara,&nbsp;Tetsuichiro Muto","doi":"10.1016/S0950-821X(05)80144-6","DOIUrl":null,"url":null,"abstract":"<div><p>Changes in tissue oxygenation in the calf muscle were measured by near-infrared spectroscopy (NIRS) in 62 patients who complained of intermittent claudication in the calf during a treadmill test. Three distinctive patterns of oxygenated and deoxygenated haemoglobin were observed. None of the type 0 cases were severe (i.e., unable to walk for more than 5 minutes), while 37 and 82% of the type 1 and type 2 cases were severe, respectively. The mean maximum walking distance of type 1 was significantly longer than that of type 2 (179 ± 70 m and 109 ± 46 m, respectively; <em>p</em> &lt; 0.005), while the mean ankle-brachial pressure index at rest of type 1 was not significantly different from that of type 2 (0.68 ± 0.19 and 0.61 ± 0.23, respectively). Our results indicate that NIRS can be used to accurately assess the severity of intermittent claudication.</p></div>","PeriodicalId":77123,"journal":{"name":"European journal of vascular surgery","volume":"8 3","pages":"Pages 294-296"},"PeriodicalIF":0.0000,"publicationDate":"1994-05-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/S0950-821X(05)80144-6","citationCount":"67","resultStr":"{\"title\":\"An objective assessment of intermittent claudication by near-infrared spectroscopy\",\"authors\":\"Takashi Komiyama,&nbsp;Hiroshi Shigematsu,&nbsp;Hiroshi Yasuhara,&nbsp;Tetsuichiro Muto\",\"doi\":\"10.1016/S0950-821X(05)80144-6\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>Changes in tissue oxygenation in the calf muscle were measured by near-infrared spectroscopy (NIRS) in 62 patients who complained of intermittent claudication in the calf during a treadmill test. Three distinctive patterns of oxygenated and deoxygenated haemoglobin were observed. None of the type 0 cases were severe (i.e., unable to walk for more than 5 minutes), while 37 and 82% of the type 1 and type 2 cases were severe, respectively. The mean maximum walking distance of type 1 was significantly longer than that of type 2 (179 ± 70 m and 109 ± 46 m, respectively; <em>p</em> &lt; 0.005), while the mean ankle-brachial pressure index at rest of type 1 was not significantly different from that of type 2 (0.68 ± 0.19 and 0.61 ± 0.23, respectively). Our results indicate that NIRS can be used to accurately assess the severity of intermittent claudication.</p></div>\",\"PeriodicalId\":77123,\"journal\":{\"name\":\"European journal of vascular surgery\",\"volume\":\"8 3\",\"pages\":\"Pages 294-296\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1994-05-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/S0950-821X(05)80144-6\",\"citationCount\":\"67\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"European journal of vascular surgery\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/S0950821X05801446\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"European journal of vascular surgery","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0950821X05801446","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 67

摘要

在跑步机测试中,用近红外光谱(NIRS)测量了62例小腿间歇性跛行患者的组织氧合变化。观察到三种不同的氧合血红蛋白和脱氧血红蛋白。0型病例均不严重(即不能行走超过5分钟),而1型和2型病例分别占37%和82%。1型的平均最大步行距离显著长于2型(分别为179±70 m和109±46 m);p & lt;静息时1型患者的平均踝肱压指数与2型患者无显著差异(分别为0.68±0.19和0.61±0.23)。我们的研究结果表明,近红外光谱可以准确地评估间歇性跛行的严重程度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
An objective assessment of intermittent claudication by near-infrared spectroscopy

Changes in tissue oxygenation in the calf muscle were measured by near-infrared spectroscopy (NIRS) in 62 patients who complained of intermittent claudication in the calf during a treadmill test. Three distinctive patterns of oxygenated and deoxygenated haemoglobin were observed. None of the type 0 cases were severe (i.e., unable to walk for more than 5 minutes), while 37 and 82% of the type 1 and type 2 cases were severe, respectively. The mean maximum walking distance of type 1 was significantly longer than that of type 2 (179 ± 70 m and 109 ± 46 m, respectively; p < 0.005), while the mean ankle-brachial pressure index at rest of type 1 was not significantly different from that of type 2 (0.68 ± 0.19 and 0.61 ± 0.23, respectively). Our results indicate that NIRS can be used to accurately assess the severity of intermittent claudication.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信