小角度差异对减法图像解译的影响

Meredith Davis BS , Kristin M. Allen MS , Ernest Hausmann DMD, PhD
{"title":"小角度差异对减法图像解译的影响","authors":"Meredith Davis BS ,&nbsp;Kristin M. Allen MS ,&nbsp;Ernest Hausmann DMD, PhD","doi":"10.1016/0030-4220(94)90075-2","DOIUrl":null,"url":null,"abstract":"<div><p>The present study examines interpretations of subtraction images of pairs of radiographs taken at 0 degrees, 1 degree, or 2 degrees of angle discrepancy. The radiographs were taken at each of 48 alveolar crestal sites on 15 dried human skulls. Computer-simulated lesions were induced at the sites on three fourths of the radiographs. Ten instructed dentists were asked to interpret the subtraction images as to the presence or absence of crestal change. A 2-degree angle discrepancy between radiographs resulted in a significant difference in sensitivity from that of radiographic pairs with a 0-degree discrepancy. However, we found no significant difference in sensitivity between 1-degree and 0-degree pairs of radiographs. In conclusion, a 1-degree geometric difference between pairs of radiographs does not significantly contribute to errors in interpretation of subsequent subtraction images.</p></div>","PeriodicalId":100992,"journal":{"name":"Oral Surgery, Oral Medicine, Oral Pathology","volume":"78 3","pages":"Pages 397-400"},"PeriodicalIF":0.0000,"publicationDate":"1994-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.1016/0030-4220(94)90075-2","citationCount":"18","resultStr":"{\"title\":\"Effects of small angle discrepancies on interpretations of subtraction images\",\"authors\":\"Meredith Davis BS ,&nbsp;Kristin M. Allen MS ,&nbsp;Ernest Hausmann DMD, PhD\",\"doi\":\"10.1016/0030-4220(94)90075-2\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<div><p>The present study examines interpretations of subtraction images of pairs of radiographs taken at 0 degrees, 1 degree, or 2 degrees of angle discrepancy. The radiographs were taken at each of 48 alveolar crestal sites on 15 dried human skulls. Computer-simulated lesions were induced at the sites on three fourths of the radiographs. Ten instructed dentists were asked to interpret the subtraction images as to the presence or absence of crestal change. A 2-degree angle discrepancy between radiographs resulted in a significant difference in sensitivity from that of radiographic pairs with a 0-degree discrepancy. However, we found no significant difference in sensitivity between 1-degree and 0-degree pairs of radiographs. In conclusion, a 1-degree geometric difference between pairs of radiographs does not significantly contribute to errors in interpretation of subsequent subtraction images.</p></div>\",\"PeriodicalId\":100992,\"journal\":{\"name\":\"Oral Surgery, Oral Medicine, Oral Pathology\",\"volume\":\"78 3\",\"pages\":\"Pages 397-400\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1994-09-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.1016/0030-4220(94)90075-2\",\"citationCount\":\"18\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Oral Surgery, Oral Medicine, Oral Pathology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://www.sciencedirect.com/science/article/pii/0030422094900752\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Oral Surgery, Oral Medicine, Oral Pathology","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/0030422094900752","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 18

摘要

本研究考察了在0度、1度或2度角度差异下拍摄的x光片对减法图像的解释。在15个干燥人头骨的48个牙槽嵴部位分别拍摄了x线片。计算机模拟的病变在四分之三的x线片上诱发。10名受过训练的牙医被要求解释这些减法图像,以判断牙冠变化的存在与否。x线片之间2度的角度差异与0度差异的x线片在灵敏度上有显著差异。然而,我们发现1度x线片和0度x线片的灵敏度没有显著差异。总之,一对x线片之间的1度几何差异不会显著导致随后减法图像的解释错误。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Effects of small angle discrepancies on interpretations of subtraction images

The present study examines interpretations of subtraction images of pairs of radiographs taken at 0 degrees, 1 degree, or 2 degrees of angle discrepancy. The radiographs were taken at each of 48 alveolar crestal sites on 15 dried human skulls. Computer-simulated lesions were induced at the sites on three fourths of the radiographs. Ten instructed dentists were asked to interpret the subtraction images as to the presence or absence of crestal change. A 2-degree angle discrepancy between radiographs resulted in a significant difference in sensitivity from that of radiographic pairs with a 0-degree discrepancy. However, we found no significant difference in sensitivity between 1-degree and 0-degree pairs of radiographs. In conclusion, a 1-degree geometric difference between pairs of radiographs does not significantly contribute to errors in interpretation of subsequent subtraction images.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信