三维治疗计划和适形辐射剂量的传递。

Important advances in oncology Pub Date : 1995-01-01
A S Lichter, R K Ten Haken
{"title":"三维治疗计划和适形辐射剂量的传递。","authors":"A S Lichter,&nbsp;R K Ten Haken","doi":"","DOIUrl":null,"url":null,"abstract":"<p><p>Three-dimensional treatment planning and conformal dose delivery have the potential to increase the effectiveness of radiation treatments. For the first time, it is possible to ensure that the intended target is being treated with the full, desired dose. By restricting the high dose region to conform more closely to the shape of the target, normal tissues receive a smaller percentage of the dose, allowing doses to be escalated to the target. New equipment, including multileaf collimators and computer-controlled treatment machines, along with faster and more sophisticated planning systems, are making 3-D planning and treatment delivery increasingly practical. The final impact of these new techniques on the ultimate outcome of a course of radiation will be ascertained through continuing clinical experience and through ongoing clinical trials.</p>","PeriodicalId":77172,"journal":{"name":"Important advances in oncology","volume":" ","pages":"95-109"},"PeriodicalIF":0.0000,"publicationDate":"1995-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":"{\"title\":\"Three-dimensional treatment planning and conformal radiation dose delivery.\",\"authors\":\"A S Lichter,&nbsp;R K Ten Haken\",\"doi\":\"\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>Three-dimensional treatment planning and conformal dose delivery have the potential to increase the effectiveness of radiation treatments. For the first time, it is possible to ensure that the intended target is being treated with the full, desired dose. By restricting the high dose region to conform more closely to the shape of the target, normal tissues receive a smaller percentage of the dose, allowing doses to be escalated to the target. New equipment, including multileaf collimators and computer-controlled treatment machines, along with faster and more sophisticated planning systems, are making 3-D planning and treatment delivery increasingly practical. The final impact of these new techniques on the ultimate outcome of a course of radiation will be ascertained through continuing clinical experience and through ongoing clinical trials.</p>\",\"PeriodicalId\":77172,\"journal\":{\"name\":\"Important advances in oncology\",\"volume\":\" \",\"pages\":\"95-109\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1995-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"\",\"citationCount\":\"0\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Important advances in oncology\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Important advances in oncology","FirstCategoryId":"1085","ListUrlMain":"","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

摘要

三维治疗计划和适形剂量递送有可能提高放射治疗的有效性。这是第一次,有可能确保预期的目标正在用期望的全部剂量进行治疗。通过限制高剂量区域,使其更接近靶标的形状,正常组织接受的剂量百分比更小,从而使剂量逐步上升到靶标。包括多叶准直仪和计算机控制的治疗机在内的新设备,以及更快、更复杂的规划系统,正在使3d规划和治疗交付变得越来越实用。这些新技术对放射治疗最终结果的最终影响将通过持续的临床经验和正在进行的临床试验来确定。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
Three-dimensional treatment planning and conformal radiation dose delivery.

Three-dimensional treatment planning and conformal dose delivery have the potential to increase the effectiveness of radiation treatments. For the first time, it is possible to ensure that the intended target is being treated with the full, desired dose. By restricting the high dose region to conform more closely to the shape of the target, normal tissues receive a smaller percentage of the dose, allowing doses to be escalated to the target. New equipment, including multileaf collimators and computer-controlled treatment machines, along with faster and more sophisticated planning systems, are making 3-D planning and treatment delivery increasingly practical. The final impact of these new techniques on the ultimate outcome of a course of radiation will be ascertained through continuing clinical experience and through ongoing clinical trials.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信