一种新的胃排空阻抗分析系统。

K Chitsakul, M Bouchoucha, J W Lee, P H Cugnenc
{"title":"一种新的胃排空阻抗分析系统。","authors":"K Chitsakul,&nbsp;M Bouchoucha,&nbsp;J W Lee,&nbsp;P H Cugnenc","doi":"10.3109/13813459408996109","DOIUrl":null,"url":null,"abstract":"<p><p>A tetra-polar electrical impedance device has been constructed to permit study of gastric emptying using a microcomputer. An alternative current of 100 kHz, 4 mM peak-to-peak, is injected through a pair of surface electrodes on the upper abdomen. The voltage variations picked up across the second pair of electrodes correspond to the variations of epigastric impedance in response to the applied current. The low frequency voltage corresponding to gastric emptying and recording noise is then conditioned and digitised at a sampling frequency of 1 Hz. A parallel 8-bit signal is finally converted to standard serial form and sent, in real time, to a microcomputer via a serial port. In a process of off-line analysis, the emptying trace was extracted from measured traces by taking successive Fast Fourier Transform (FFT) of length 64 points and was then fit by three mathematical models: linear, exponential and Weibull. The rate of emptying was calculated in terms of the time needed to achieve 50% emptying (T 1/2) from the best fit model. A clinical experiment was done in 20 healthy volunteers to investigate the reproducibility of the method and compared to a scintigraphic method. Successive measurements on the same subject gave statistically similar results and were statistically independent. No correlation has been observed between impedance and scintigraphic methods.</p>","PeriodicalId":77008,"journal":{"name":"Archives internationales de physiologie, de biochimie et de biophysique","volume":"102 1","pages":"71-6"},"PeriodicalIF":0.0000,"publicationDate":"1994-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://sci-hub-pdf.com/10.3109/13813459408996109","citationCount":"1","resultStr":"{\"title\":\"A new system for gastric emptying analysis using impedance measurement.\",\"authors\":\"K Chitsakul,&nbsp;M Bouchoucha,&nbsp;J W Lee,&nbsp;P H Cugnenc\",\"doi\":\"10.3109/13813459408996109\",\"DOIUrl\":null,\"url\":null,\"abstract\":\"<p><p>A tetra-polar electrical impedance device has been constructed to permit study of gastric emptying using a microcomputer. An alternative current of 100 kHz, 4 mM peak-to-peak, is injected through a pair of surface electrodes on the upper abdomen. The voltage variations picked up across the second pair of electrodes correspond to the variations of epigastric impedance in response to the applied current. The low frequency voltage corresponding to gastric emptying and recording noise is then conditioned and digitised at a sampling frequency of 1 Hz. A parallel 8-bit signal is finally converted to standard serial form and sent, in real time, to a microcomputer via a serial port. In a process of off-line analysis, the emptying trace was extracted from measured traces by taking successive Fast Fourier Transform (FFT) of length 64 points and was then fit by three mathematical models: linear, exponential and Weibull. The rate of emptying was calculated in terms of the time needed to achieve 50% emptying (T 1/2) from the best fit model. A clinical experiment was done in 20 healthy volunteers to investigate the reproducibility of the method and compared to a scintigraphic method. Successive measurements on the same subject gave statistically similar results and were statistically independent. No correlation has been observed between impedance and scintigraphic methods.</p>\",\"PeriodicalId\":77008,\"journal\":{\"name\":\"Archives internationales de physiologie, de biochimie et de biophysique\",\"volume\":\"102 1\",\"pages\":\"71-6\"},\"PeriodicalIF\":0.0000,\"publicationDate\":\"1994-01-01\",\"publicationTypes\":\"Journal Article\",\"fieldsOfStudy\":null,\"isOpenAccess\":false,\"openAccessPdf\":\"https://sci-hub-pdf.com/10.3109/13813459408996109\",\"citationCount\":\"1\",\"resultStr\":null,\"platform\":\"Semanticscholar\",\"paperid\":null,\"PeriodicalName\":\"Archives internationales de physiologie, de biochimie et de biophysique\",\"FirstCategoryId\":\"1085\",\"ListUrlMain\":\"https://doi.org/10.3109/13813459408996109\",\"RegionNum\":0,\"RegionCategory\":null,\"ArticlePicture\":[],\"TitleCN\":null,\"AbstractTextCN\":null,\"PMCID\":null,\"EPubDate\":\"\",\"PubModel\":\"\",\"JCR\":\"\",\"JCRName\":\"\",\"Score\":null,\"Total\":0}","platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archives internationales de physiologie, de biochimie et de biophysique","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3109/13813459408996109","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 1

摘要

为了用微型计算机研究胃排空,研制了一种四极电阻抗装置。通过上腹部的一对表面电极注入100千赫,4毫米峰对峰的交流电。在第二对电极上采集到的电压变化与上腹部阻抗随施加电流的变化相对应。然后以1hz的采样频率调节和数字化与胃排空和记录噪声相对应的低频电压。一个并行的8位信号最后被转换成标准的串行形式,并通过串行端口实时发送到微型计算机。在离线分析过程中,通过64点的连续快速傅里叶变换(FFT)从测量的轨迹中提取空迹,然后通过线性、指数和威布尔三种数学模型进行拟合。排空率根据最佳拟合模型达到50%排空所需的时间(t1 /2)计算。在20名健康志愿者中进行了临床实验,以研究该方法的可重复性,并与扫描法进行了比较。对同一受试者的连续测量结果在统计上相似,且在统计上是独立的。没有观察到阻抗和科学方法之间的相关性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
A new system for gastric emptying analysis using impedance measurement.

A tetra-polar electrical impedance device has been constructed to permit study of gastric emptying using a microcomputer. An alternative current of 100 kHz, 4 mM peak-to-peak, is injected through a pair of surface electrodes on the upper abdomen. The voltage variations picked up across the second pair of electrodes correspond to the variations of epigastric impedance in response to the applied current. The low frequency voltage corresponding to gastric emptying and recording noise is then conditioned and digitised at a sampling frequency of 1 Hz. A parallel 8-bit signal is finally converted to standard serial form and sent, in real time, to a microcomputer via a serial port. In a process of off-line analysis, the emptying trace was extracted from measured traces by taking successive Fast Fourier Transform (FFT) of length 64 points and was then fit by three mathematical models: linear, exponential and Weibull. The rate of emptying was calculated in terms of the time needed to achieve 50% emptying (T 1/2) from the best fit model. A clinical experiment was done in 20 healthy volunteers to investigate the reproducibility of the method and compared to a scintigraphic method. Successive measurements on the same subject gave statistically similar results and were statistically independent. No correlation has been observed between impedance and scintigraphic methods.

求助全文
通过发布文献求助,成功后即可免费获取论文全文。 去求助
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:481959085
Book学术官方微信